5.6 Connecting the signal lights for the automatic timer function
(Control 220, item no. 152 814)
Function: The signal lights flash when the operator is running.
If the automatic timer is switched on, the signal lights also flash during
the warning phase (for programming see page 16).
Connecting the relay circuit board
Always attach the flat-cable plugs so that the cable is angled in
the direction of the circuit board edge.
Connect the relay circuit board and the control unit using the enclosed
flat cable.
Relay circuit board: Plug connection X4a
Control unit: Plug connection X8b (32)
Wiring diagram detail for signal lights relay:
5. Connection and initial operation of the extensions
Legend:
D40 SIGNAL LIGHTS control light
F 5 Mains fuse (max. 4A)
H41 EXIT signal light (amber)
H43 ENTER signal light (amber)
K40 SIGNAL LIGHTS relay
Plug connections
X4a Relay triggering
X4b Relay triggering