10
Return the transparent cover to the operator.
3.3 2 Dynamic 3-101 - 3-108
1. Move the door by hand to its mechanical travel limit OPEN.
2. Open housing cover on door operator.
3. Release the stop (grub screw J) of control cam (B).
4. Set control cam (B) in such way, that the reference point switch (G)
is actuated according to fig. 7 (position H) - approx. 2 angular degrees from
switch point.
5. Fix control cam (B) by screwing on grub screw (J).
6. Then install housing cover again.
7. Connect to power supply and actuate buttom CLOSE (12).The door travels
to its travel limit CLOSE which is set by factory.
3. Initial operation of the Control 120 - 123 control units