16
E N G L I S H
Control 110 base control for sectional doors, 380 V 3-phase current
Control 111 base control for sectional doors, lockable, 380 V 3-phase current
Control 112 base control for sectional doors, for two opening heights, 380 V 3-phase current
Control 113 base control for sectional doors, for two opening heights, lockable, 380 V 3-phase current
Control 116 base control for sectional doors, 220 - 240 V AC
Control 117 base control for sectional doors, lockable, 220 - 240 V AC
Control 118 base control for sectional doors, for two opening heights, 220 - 240 V AC
control 119 base control for sectional doors, lockable, 220 - 240 V AC
With the base controls Control 110-113 and Control 116-119, sectional doors can be opened or closed by impulse
operation or directional control with self-hold. The self-hold function for the OPEN or CLOSE operational directions is
adjustable via a programming switch. For the
CLOSE operating direction with self-hold function, a closing edge safety device with optosensor is required.
Integrated in the base control is an RPM monitoring device which can be adjusted in 16 stages via two rotary switches.
The following command units or supplementary controls can be connected to the plug-in connecting terminals provided:
Button IMPULSE, STOP
Button OPEN, STOP, CLOSE
Key switch IMPULSE
Key switch OPEN, CLOSE
Electronic aerial with learnable safety coding
Wicket door contact, cable slack device, cable safety device
Photocell for added safety in the garage entry/exit area
Control 200, 210 automatic timed return
Control 300 traffic light control
Control 400 digital induction loop
1. Overview of Control 110 control unit
A „OPEN“ button and end of travel OPEN LED
B Optosensor and remote control LED
C „STOP“ button
D Control voltage LED
E „CLOSE“ button and end of travel CLOSE LED
F Main switch
2. A Rotary switch power limit „OPEN“
B Rotary switch power limit „CLOSE“
C Switch S7
D Remote control coding button
E Plug connection X8 for 3 min. light
F Switches S8a, S8b
G Plug connection for membrane key
H Plug connection X2f for Control 200, Control 300 and potential-free limit switch contacts
I Switch S19
J Switch S20
K Connecting terminals A, Z
L Plug socket for electronic aerial
M Connecting terminal X2e for photocell 24 V
N Connecting terminal X2d for supplementary OPEN, CLOSE, STOP, IMPULSE buttons
O Connecting terminal X2c for OPEN, CLOSE, STOP , IMPULSE buttons
P Connecting terminal X2a for limit switches S11,S13,S14 and RPM detector
Q Plug socket for optosensor
R Protective conductor connection
S Connecting terminal block X2 for motor connection
T Connecting terminal block X2 for mains voltage
U Mains fuse F2-F4, 6.3 A max.
V Control fuse F1, 80 mA max.
3. Overview of on-site wiring work (by others):
A Operator type Dynamic 112 with quick release
B Operator type Dynamic 111 with emergency hand chain
4. Overview of on-site wiring work (by others):
Operator type Dynamic 201