Manual for installation and operation, Comfort 870 GB (#81125) 27
6.6 Connection of control elements
Attention!
In order to avoid damaging the
controls:
- The local safety regulations must be
complied with at all times.
- It is very important that mains cables
are laid separately from control cables.
- The controls voltage must be 24 V DC.
- If external voltages are applied at
terminals XM70A, XV51A, XM70B,
XV51B, XB99, XP54B, XP54A, XP62B,
XP62A or XB70, the entire electronic
system will be destroyed.
- Only potential-free contacts may be
connected to terminals B9, 5, 34, 3
and 8 (XB99).
- The connections XM70B and XV51B
are not to be used!
Caution!
Danger of electric shock:
Before any cabling works begin, it must
be ensured that the cables are
disconnected from the power supply.
During cabling works, it must be
ensured that the cables remain
disconnected from the power supply at
all times (e.g. prevent reconnection).
6.6 / 1
6. Installation
XN01
XV51B
XM70B
XM70A
XV51A
XB99
XP54A
XB70
XP54B
XH01
Reference:
When installing external control
elements, or safety and signal
equipment, the relevant instructions
must be observed.
XB70 Connection of modular antenna 8.1
XB99
Connection of external control
elements
6.6 / 2
6.6 / 3
6.6 / 4
6.6 / 5
XH01
Connection and programmable
output (e.g. signal light,
24 V DC, 0.5 A)
6.6 / 6
6.6 / 7
6.6 / 8
XM70A Connection for motor 6.7
XM70B Connection has no function -
XN01 Connection for mains cable 6.8
XP54A
Connection for closing edge
safety device, gate travelling
direction CLOSE
6.6 / 9
XP54B
Connection for closing edge
safety device, gate travelling
direction OPEN
6.6 / 9
XP62A
Connection for photocell,
gate travelling direction CLOSE
6.6 / 10
XP62B
Connection for photocell,
gate travelling direction OPEN
6.6 / 10
XV51A
Connection for RPM/reference
point sensor
-
XV51B Connection has no function -
XP62A
XP62B