9. Extended operator functions
Menu 1: Automatic closing timer
Setting
Gate open
duration
(seconds)
Warning time
(seconds)
Automatic
closing timer
other functions
A1 - - deactivated -
B1 15 5 activated
Extension of door OPEN time only through impulse signal
(button, hand transmitter)
C1 30 5 activated
D1 60 8 activated
E1 15 5 activated
Interruption of the gate open duration after the photocell bar-
rier has been driven past
F1 30 5 activated
G1 60 8 activated
H1 unlimited 3 activated
Closes after the photocell barrier has been driven past / closing
prevention
Advice:
Without a connected photocell or closing prevention device, only parameter A1 can be adjusted.
Menu 7: Signal light
Setting Gate movement / Warning Gate stoppage
A7 flashing OFF (Electricity saving)
B7 lighting OFF (Electricity saving)
C7 flashing flashing
D7 lighting lighting
E7 flashing lighting
F7 lighting
flashing
Reference:
The signal light connection can be adjusted in level 1, menu 7.