English Page 66
G. Display functions and programming possibilities
Extended operator functions - 6. Programming level
(Reversion modes)
28
Menu 1: Power limit for OPEN direction
Menu 4: Photocell for CLOSE direction
Menu 3: Photocell for OPEN direction
Menu 5: Closing edge safety device for OPEN direction
Menu 6: Closing edge safety device for CLOSE direction
Menu 2: Power limit for CLOSE direction
BUTTON P
BUTTON
BUTTON
1234567
STOP SHORT LONG NO
reverse reverse existing
STOP SHORT LONG NO
reverse reverse existing
STOP SHORT LONG NO
reverse reverse existing
STOP SHORT LONG NO
reverse reverse existing
STOP SHORT LONG NO
reverse reverse existing
STOP SHORT LONG NO
reverse reverse existing
Settings from factory not possible
GB
English Page 27
G. Display functions and programming possibilities
General advice regarding the programming of control unit
Display of the reference point
The operator passes the reference point sensor:
• LED 5 shortly glows up.
Advice:
The end positions can only be programmed if there is a
valid reference point. For this travel the door electrically
once to open or close position.
Advice regarding programming:
If the control unit is in programming mode and none
of the three programming buttons (, ,) is pressed
during a time period of 120 sec., the programming
procedure is cancelled and the control unit changes
to operating mode).
• Press button or to travel the door
to the desired door position.
Set the positions
Advice:
The control unit works
without press-and-hold!