English Page 27
Start-up:
Power-operated windows, doors and gates for industrial use have to be checked by a specialist
after installation, before first operation and when necessary. Minimum check interval once a
year.
Maintenance instructions
The Comfort 200 Garage Door Operator works largely maintenance-free.
Please observe following points in order to guarantee a function without troubles:
• Check regularly the settings of 'OPEN and CLOSE' automatic cut-out.
• Check regularly all movable parts of door and motor system and keep them easily movable.
• Manual operation should run easily, check as well regularly the separate counterbalance of
the door
Technical data:
Garage Door Operator
Comfort 200
Connected loads:
230 V
250 W (operating with lighting)
Door travel speed:
0,12 m/s
Push and pull force:
400 N
Excess travel stop:
88 Sek.
Lighting:
1x 40 W E 14,
automatic switch-off after approx. 180 sec.
Control voltage:
low voltage 24 V DC
Automatic cut-out:
electronic power limit by microprocessor and current sensor.
Protection category:
only for dry buildings
O
21
O