EnglishDeutsch Page 41
Programming options
O
20
Overview of the indicator functions and programming options
Indicator functions
After plugging in at the mains, indicators 1 - 8 glow and the operator lighting comes
on for approx. 2 seconds. The indicators and the operator lighting then go out.
The control unit is in the operating state. Indicator 8 glows.
(If an OPEN or CLOSE travel limit is reached, the corresponding LED glows as well).
Error messages
If the MALFUNCTION indicator flashes, after briefly pressing button P the
corresponding error number is displayed (indicators flash erratically).
The error number is arrived at by adding together the flashing numbers.
See pt. 27 "Error numbers".
Programming the basic functions of the operator
Press button P for longer than 2 seconds. The control unit then changes from the
operating state to the programming state of the basic functions. Indicator 1 flashes,
all other indicators glow. Now release button P.
Using the
O
+ or
O
- buttons, changes can be made in the programming menu and
then stored by pressing button P. (If button P is pressed without any change having
been made via the
O
+ or
O
- buttons, the programming menu is skipped and the
settings remain unchanged.) After the last programming menu, programming of the
basic functions of the operator is completed; recognizable by all the indicators going
out in the sequence 8 - 1.
Programming menus
1. Photocell, operation with or without external photocell
2. OPEN travel limit
3. CLOSE travel limit
4. OPEN automatic cut-out
5. CLOSE automatic cut-out
6. Coding the remote control
Programming the extended operator functions
Press button P for longer than 10 seconds. The control unit than changes from the
operating state to the programming level for extended operator functions.
Indicator 3 flashes rapidly, all other indicators glow. Whilst continuing to press
button P, use buttons
O
+ or
O
- to select the desired programming level
(indicator of the level flashes rapidly, all other indicators glow).
Now release button P.
The first programming menu of the chosen level is selected (indicator 1 flashes,
all other indicators glow). Using the
O
+ or
O
- buttons changes can be made in the
}
(power limit)
Seite 24
Programmiertabelle Ebene 5
Antriebsbeleuchtung/Signalleuchten
(Fortsetzung)