3. STOPPING THE GENERATOR
(a)
Turn off the power switch of the electric equipment and unplug the cord from receptacle of the generator.
(b) Allow the engine about 3 minutes to cool down at no load before stopping.
(c) Turn the engine switch to the position " " (STOP). (See Fig. 4-e)
q "" (RUN) w
"" (STOP)
4. OIL SENSOR (See Fig.
44
-
rr
)
q OIL SENSOR
(a) The oil sensor detects the fall in oil level in the crankcase and automatically stops the engine when the oil
level falls below a predetermined level.
(b) When engine has stopped automatically, switch off generator's no fuse breaker, and check the oil level.
Refill engine oil to the upper level as instructed on page 5 and restart the engine.
(c) If the engine does not start by usual
starting procedures, check the oil level.
Do not remove OIL SENSOR PROBE when refilling with oil.
Remove oil filler cap on the opposite side of carburetor.
CAUTION
(d) Turn on the switch of the appliance.
NOTE
When the no fuse breaker turns off during operation, the generator is over loaded or the appliance is
defective.
Stop the generator immediately, check the appliance and / or generator for overloading, and have repaired
as necessary by Makita factory or authorized service center.
TABLE 1
To take power out from the TWIST LOCK
RECEPTACLE, insert the plug into the
receptacle, and turn it clockwise to the lock position. (See Fig.
44
-
ww
)
Be sure to ground the generator if the
connected electrical device is grounded.
WARNING
Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a current
exceeding the specified amperage.
Be sure that the total wattage of all appliances dose not exceed the rated output of the generator.