Fuel system damage or engine performance problems
resulting from neglected storage preparation is not
covered by the Distributor’s Limited Warranty.
Fuel storage life can be extended by adding a gasoline
stabilizer that is formulated for that purpose. Or, drain the
carburetor, sediment cup (if applicable) and/ or fuel tank to
avoid fuel deterioration problems.
Service according to the table below:
Draining the Fuel Tank and Carburetor
(Fig. 21)
WARNING:
Gasoline is highly flammable and explosive.
Burns or severe personal injury may result from
handling fuel.
Stop the engine and keep heat, sparks, and flames
away.
Handle fuel only outdoors.
Wipe up spills immediately.
1. Loosen the drain screw and drain the carburetor.
Drain the gasoline into a suitable container.
2. Place a suitable gasoline container below the
sediment cup, and use a funnel to avoid spilling
gasoline.
3. Remove the sediment cup, and then turn the fuel
valve lever to the “I (ON)” position.
4. Allow the gasoline to drain completely, and then
reinstall the sediment cup.
Engine Oil (Fig. 22)
1. Change the engine oil.
2. Remove the spark plug.
3. Pour a teaspoon (5 - 10 cc) of clean engine oil into the
cylinder.
4. Pull the starter grip several times to distribute the oil in
the cylinder.
5. Reinstall the spark plug.
6. Pull the starter grip slowly until resistance is felt. The
piston is coming up on its compression stroke at this
point, and both the intake and exhaust valves are
closed. Storing the engine in this position will help to
protect it from internal corrosion. Return the starter
grip back gently to its original position.
Storage Precautions
If the generator is to be stored with gasoline in the fuel
tank and carburetor, it is important to reduce the hazard of
gasoline vapor ignition.
Select a well ventilated storage area away from furnaces,
water heaters, or clothes dryer, or any other appliance
that operates with a flame. Also avoid areas with a spark-
producing electric motor, or where power tools are
operated.
Since high humidity promotes rust and corrosion, avoid
storage areas with high humidity when possible.
Unless all of the fuel has been drained from the fuel tank,
leave the fuel valve in the “O (OFF)” position to reduce the
possibility of leakage.
Place the generator on a stable and level surface. Tilting
can cause the fuel or oil to leak.
Once the engine and exhaust system are cool, cover the
generator to keep out dust. A hot engine and exhaust
system can ignite or melt certain materials.
Do not use sheet plastic as a dust cover. A nonporous
cover will trap moisture around the generator, promoting
rust and corrosion.
Removal from Storage
Check the generator as described in the “PRE-
OPERATION CHECKS” chapter of this manual.
Fill the fuel tank with fresh gasoline if the fuel was drained
during storage preparation. If gasoline for refueling is kept
in a container, be sure that it contains only fresh gasoline.
Gasoline oxidizes and deteriorates over time, and using
oxidized and/or deteriorated oil will cause hard starting.
Note that if the cylinder was coated with oil during storage
preparation, it is normal for the engine to smoke briefly at
startup.
TRANSPORTING (Fig. 23)
When transporting the generator, turn off the engine
switch and the fuel valve. Keep the generator stable and
level to prevent fuel from spilling. Fuel vapor or spilled fuel
may ignite.
LENGTH OF STORAGE RECOMMENDED SERVICE PROCEDURES TO PREVENT HARD STARTING
Less than 1 month No preparation required.
1 to 2 months Fill with fresh gasoline and add gasoline stabilizer*.
2 months to 1 year
Fill with fresh gasoline and add gasoline stabilizer*.
Drain the carburetor float bowl and the fuel sediment cup.
1 year or more
Fill with fresh gasoline and add gasoline stabilizer*.
Drain the carburetor float bowl and the fuel sediment cup.
Remove the spark plug and put a teaspoon of engine oil into the cylinder. Turn the
engine slowly with the recoil starter to distribute the oil. Then, reinstall the spark
plug.
Change the engine oil.
After removing the generator from storage, drain the stored gasoline into a suitable
container, and fill with fresh gasoline before starting.
*Use gasoline stabilizers that are formulated to extend storage life.
Follow the manufacturer’s instructions for use.
Contact our authorized Makita generator dealer for stabilizer recommendations.
14

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Makita EG2850A bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Makita EG2850A in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 3,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info