PELLET STOVES Chapter 6
INSTALLATION AND USE MANUAL
page 49
Safety devices Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
6.4. BLACKOUT WITH STOVE LIT (panel display:
RELIGHTING AFTER BLACKOUT for 10’, then
LIGHTING)
In the case of no mains supply (BLACKOUT) the stove performs as
follows:
Blackout less than 10”: it restores operation in progress;
If there is no power supply for more than 10" when the stove is
lit or in the lighting phase, when the stove is powered again it
returns to the previous operating condition following the
procedure below:
1. It cools down by activating the smoke extractor at the
minimum for 10’ and proceeds to the next point;
2. It restores the stove to the operating condition before
the blackout.
During phase 1 the panel displays RELIGHTING AFTER BLACKOUT.
During phase 2 the panel displays Lighting.
If during phases 1-2 the stove receives commands from the panel (or
from the remote control) and therefore manually performed by the
user, the stove stops running blackout recovery and proceeds with
lighting or shutdown as the command requests.
If the power supply cut is LONGER THAN 10” with the stove in
shutdown phase, when the stove is powered again it restarts in
shutdown mode even if the smoke temperature has dropped below
45°C in the mean time. This last phase can be skipped by pressing key
0/1 (passes on to lighting) and by pressing it again (it recognises that
the stove is off).
Clean the grate “F” from ash and any incrustations which could
obstruct the air passage holes.