PELLET STOVES Chapter 5
INSTALLATION AND USE MANUAL
page 36
Menu structure Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
5.2.2. DETAILS OF TIMER OPERATION
1. The lighting time scrolls from 00.00 (midnight) to 23.50
2. If you change the lighting time and set a value later than the
shutdown time, the shutdown time automatically sifts to
lighting time + 10 min. to avoid operative errors.
3. The shutdown time may be chosen between lighting time +10
min. and 00.00 (midnight).
4. If a timer programme switches the stove off at 00.00
(midnight) on one day and another programme lights it at
00.00 (midnight) of the next day: the stove remains
continuously lit.
5. If the stove is lit and the timer active, it is possible to manually
shutdown the stove by pressing the OFF key; the stove shuts
down and shall relight automatically at the next time foreseen
by the timer
6. Equally in the stove off and timer active state, press the ON
key: the stove will light and shutdown at the time foreseen by
the active timer.
IMPORTANT NOTE
The stove takes about 15 minutes to light.
Take this into account when setting the start time.
Likewise, stove shutdown requires about 30 minutes,
during which the heat stored up by the stove is still
released into the room.
Keep this in mind for substantial fuel savings.
5.2.3. TIMER de-activation.
To de-activate the timer, access the menu again by means of button
OFF.
ATTENTION!
The TIMER function can be activated/deactivated
whether the stove is on or off.
If a timer programme has been activated, in the
initial screen the stove operating status
(on/off/start-up….) alternates with the word “TIMER
P01 active” (example)