Do not use any sort of rigid device which might bend
the blades. When rotating, bent blades will produce
more noise than normal due to off-axis rotation of
the fan.
7.1.5.2.
Control unit COMFORT AIR
Does not require any special maintenance if located as instructed in
chapter 5.4.
From time to time, you may want to check the condition of
the fuse.
7.1.5.3.
Wiring
Make sure the wiring is in good condition and that it is not near the hot
body of the fireplace stove. Heat may damage it.
7.2. CLEANING TO BE DEALT WITH BY SPECIALIZED
TECHNICIAN
7.2.1. Cleaning flue pipe
Mechanical cleaning of the flue pipe is recommended at least once a
year. Excessive deposits of unburnt solid material can cause problems
with the evacuation of smoke, and gives rise to a risk of chimney fires.
To clean the appliance's chimney, remove the smoke deflector. To
remove it correctly, lift the front and at the same time slide it forward in
order to free it from rear support.