A
B
C
D
E
A
B
C
D
15°
E
F
A
B
C
D
E
30°
F
9
4-FLUE
Technical Dept. - All rights reserved - Reproduction is prohibited
TECHNICAL CHARACTERISTICS
Have the eciency of the ue checked by an authorised technician.
The ue must be sealed against ue gasses, in a vertical direction without narrowing, be made with materials impermeable to smoke,
condensation, thermally insulated and suitable to resist normal mechanical stress over time (we recommend replaces made of A/316
or refractory material with insulated round section double chamber). Be suitably insulated externally to avoid condensation and reduce
smoke cooling. It should be separated from combustible or ammable materials with an air gap or insulating materials: check the
distance specied by the manufacturer of the replace according to EN1443. The chimney opening must be in the same room as the
appliance, or at most in the adjoining room, and have a soot and condensation collection chamber beneath the opening, and be accessible
via a sealed metal hatch.
FLAT ROOF
ROOF AT 15°
ROOF AT 30°
A = 0.50 metres
B = DISTANCE > 2 metres
C = DISTANCE < 2 metres
D = 0.50 metres
E = TECHNICAL VOLUME
A = MIN. 1.00 metres
B = DISTANCE > 1.85 metres
C = DISTANCE < 1.85 metres
D = 0.50 metres above highest
point
E = 0.50 metres
F = REFLUX AREA
A = MIN. 1.30 metres
B = DISTANCE > 1.50 metres
C = DISTANCE < 1.50 metres
D = 0.50 metres ABOVE
HIGHEST POINT
E = 0.80 metres
F = REFLUX AREA
FIGURE 2
FIGURE 3
FIGURE 4