643573
17
Verklein
Vergroot
Pagina terug
1/40
Pagina verder
INSTALLATION GUIDE EN
SEALED PELLET STOVE
CURVE
comfort Air
- part 2 -
Instructions in English
II
TABLE OF CONTENTS
TABLE OF CONTENTS .................................................................................................. II
10FIRST STARTUP .....................................................................................................3
11REMOTE CONTROL MAX ..........................................................................................4
12EMERGENCY PANEL ..............................................................................................11
13OPERATION .........................................................................................................13
14SAFETY DEVICES ..................................................................................................17
15ALARMS ..............................................................................................................18
16RECOMMENDATIONS FOR SAFE USE .......................................................................24
17CLEANING ...........................................................................................................25
18FAULTS/CAUSES/SOLUTIONS .................................................................................34
19CIRCUIT BOARD ...................................................................................................37
3
10-FIRST START-UP
Technical Dept. - All rights reserved - Reproduction is prohibited
PRECAUTIONS BEFORE START-UP
GENERAL PRECAUTIONS
Remove all parts that may burn from the brazier and the glass (manual, various adhesive labels or any polystyrene).
Check that the brazier is positioned correctly and rests properly on the base.
The rst start-up may not be successful as the feed screw is empty and does not always manage to load the required
amount of pellets in time to light the ame.
ELIMINATE THE ALARM CONDITION OF A FAILED START-UP BY POSITIONING THE OF THE EMERGENCY PANEL TO OFF FOR
ABOUT 20 SECONDS AND BRINGING SELECTOR “D” BACK TO THE REMOTE POSITION. REMOVE THE PELLET LEFT IN THE
BRAZIER AND REPEAT THE START-UP. (SEE “SAFETY DEVICES/ALARMS” PARAGRAPH)
If after repeated attempts, the ame fails to ignite, despite a regular ow of pellets in the brazier, which must rest snugly against the
slots. If no anomaly is found during this inspection, there may be a problem with the product components or installation may not be
correct.
REMOVE THE PELLETS FROM THE BRAZIER AND CONTACT AN AUTHORISED TECHNICIAN.
Do not touch the boiler during the rst lighting, as it is during this phase that the paint sets. If you touch the paint,
you may expose the steel surface.
If necessary, touch up the paint with the spray can of the specic colour. (See “Pellet stove accessories”)
It is good practice to ensure eective ventilation in the room during the initial start-up, as the boiler will emit some
smoke and smell of paint.
Do not stand close to the stove and, as mentioned, air the room. The smoke and smell of paint will disappear after about an hour of
operation, however, they are not harmful in any case.
The boiler will be subject to expansion and contraction during the lighting and cooling down stages, and may therefore make slight
creaking noises.
This is absolutely normal as the structure is made of laminated steel and must not be considered a defect.
It is extremely important to make sure the boiler does not reach high temperatures straight away, but to increase the temperature
gradually using low power at rst.
This will prevent damaging the ceramic or serpentine stone tiles, the welds and the steel structure.
DO NOT EXPECT HEATING EFFICIENCY IMMEDIATELY!!!
A
B
E
C
D
4
11-REMOTE CONTROL MAX
GENERAL FEATURES OF THE LCD REMOTE CONTROL
The remote control works at a transmission frequency of 434.5 MHz. Power the product with 3 AAA batteries as follows:
Remove the battery compartment cover by sliding it downwards (according to the arrow).
Insert the batteries according to the correct polarity (+) and (-).
Close the battery compartment cover.
When the remote control is powered it automatically prompts to set the time.
The remote control has a special icon on the display to indicate when the batteries are almost at. If the at battery icon appears, the
batteries are almost at and the remote control is about to switch o.
Used batteries contain metals which are harmful to the environment, so they must be disposed of separately in
appropriate containers.
GRAPHIC APPEARANCE
In the instructions we will often refer to the indications of the keys shown in the gure. Always keep it at hand for simplicity’s sake.
MAN
12:02
31
MAX
°C
TU
12:03
31
°C
TU
35
°C
AUTO
5
11-REMOTE CONTROL MAX
Technical Dept. - All rights reserved - Reproduction is prohibited
REMOTE CONTROL OPERATION
General rules
By pressing key A for 1” the product is switched on and o. Key C is used to make all changes. Key E is used to conrm the changes. By
pressing key B one selects the product operating mode. Via key D one browses the FAN and SLEEP setting. Whichever the mode is, press
key A briey (or leave the keypad idle for 7”) to go back to the initial display.
INITIAL SETTINGS
Setting the time
Both with the remote control on and o, by pressing keys B+E at the same time for 3” one accesses the time/day setting mode.
The hour digits will start to ash; they can be changed with key C. By pressing key E the changes are conrmed.At this point the minutes
digits will start to ash.
Follow the same modify/conrm procedure, one will then go onto the time display mode (12h or 24h) and nally
the day will start to ash. Conrm this data to exit the settings.
NOTE: each time the remote control is powered, the time is reset and the display automatically enters the time setting mode.
°C – °F setting
Only with the stove switched o, by pressing key B for 5” one changes the unit of measure of the temperature, from Celsius to Fahrenheit
and vice versa.
SETTING THE OPERATING MODE
With the remote control switched on, key B allows to set one of the 4 product operating modes. Figure 1-2-3-4
displays the 4 basic displays, respectively: Manual, Automatic, Timer and Eco mode.
MANUAL Mode (MAN)
In this mode one can set the ame power manually (5 levels - act directly on key C to change). Figure 1
AUTOMATIC Mode (AUTO)
In this mode one can set the desired room temperature, and the stove will modulate the ame power automatically to reach the
temperature. Figure 2
If a fan is AUTOMATICALLY set, its speed depends on the power that is running the stove:
In the case of power level 1: V=1
In the case of power level 2: V=2
In the case of power level 3: V=3
In the case of power level 4: V=3
In the case of power level 5: V=3
FIG.1 FIG.2
MAN
12:02
31
MAX
°C
TU
6
11-REMOTE CONTROL MAX
MANUAL POWER FUNCTION
this function allows you to set the power of the ame from a minimum of 1 to a maximum of 5. The power levels correspond to a dierent
value of fuel consumption, setting 5 heats the room in less time and setting 1 can keep the room temperature stable for a longer period of
time. The set ame is automatically set to a minimum when the set temperature value is reached.
if the bars are all full, the stove is on ame power 5
if only one bar is full, the stove is on ame power 1
If the ventilation is MANUALLY set, the function which limits the maximum power of the stove according to the ventilation is enabled.
COMFORT AIR (2 FANS): maximum power level = total of the levels of ventilation.
Even if the power limit is enabled, the display on the remote control does not consider the power limit for ventilation eect.
FLAME POWER
8:20
26
FR
20
°C
TIMER
°C
P1
12:06
31
°C
TU
23
°C
ECO
12:07
31
°C
TU
23
°C
TIMER
ECO
7
11-REMOTE CONTROL MAX
Technical Dept. - All rights reserved - Reproduction is prohibited
TIMER Mode (TIMER)
Select this operating mode to switch the product on and o automatically, according to 6 customised time slots (P1 – P6). The following
can be set for each time slot:
Switch-on time
Switch-o time
Desired room temperature in the time slot
Days of the week in which the time slot is active
When the stove is switched on (manually via key A or automatically via a time slot) the product works in the
automatic mode described above. A time slot appears automatically when it is active (P1 in gure 3) and the desired temperature is
changed according to the value set in the time slot. However, the user can always modify this value as desired and in real time.
Refer to the relevant paragraph to learn how to set the time slots.
ECO Mode (ECO)
This mode is activated/disabled with the remote control switched on by pressing key B for 5”.
ECO is an automatic mode with the only dierence that if the set temperature is reached and remains so for the following 20 minutes
(despite ame modulation), the product switches o and remains on stand-by until the room temperature drops 2 degrees below the
desired temperature (and in any case for at least 5 minutes from the last shutdown). The product is then switched on again. Figure 4
If the room is not suciently insulated, ame modulation does not allow the set temperature to stay satised for 20 consecutive minutes
and the product will not switch o.
NOTE: It is recommended to use the ECO mode only in well-insulated rooms in order to prevent start-up and shutdown
from occurring within short periods of time.
The remote control remains on even when the product is o when in ECO mode, in order to indicate that this shutdown is only
temporary. Obviously, if the product is switched o via key A, ECO mode is exited and the product remains o.
Up to 6 automatic start-up and shutdown time slots (E1 – E6) can also be set in ECO mode, which are independent
from those of TIMER mode (P1 – P6). If they have been activated, TIMER-ECO appears on the display (gure 5) permanently, even if the
remote control is switched o.
Refer to the relevant paragraph to learn how to set the time slots.
NOTE: If the remote control is switched o due to TIMER, ECO cannot be restarted until the user intervenes (key A) or
when the next valid time slot starts. Combined use of TIMER and ECO modes requires a good knowledge of the product
operating logic.
FIG.3 FIG.5FIG.4
26
°C
8
11-REMOTE CONTROL MAX
Room ventilation
Room ventilation can be adjusted as desired in all 4 operating modes described above (Manual, Automatic, Timer, Eco). Simply perform
this operation: from the basic display, press key D to access the VENTILATION adjustment mode (Fig. 6). Then press key C (arrows) to set the
desired ventilation by selecting one of the 5 levels available, independent from the ame level.
The “auto option can also be selected, which automatically links the room ventilation speed to the ame level.
In short:
ame set on 1 > ventilation set on 1; ame set on 3 > ventilation set on 3; ame set on 5 > ventilation remains set on 3 (for silent
operation as it is in automatic mode).
In products with 2 room fans (comfort air models) via key D one can scroll and set the speed of the individual fans (identied with 1 or 2
above the level bars).
NOTE: In the event a replacement remote control is purchased, if you need to change the default setting, proceed as
follows: with the remote control switched on press buttons D + E at the same time for 10 seconds (until the ashing
number appears). Press key C to select 1 or 2 according to the product to which the remote control is to be paired, and
press E to exit.
IMPORTANT! Choosing the right number of fans can become a decisive factor to ensure the stove works correctly. Therefore
ensure an authorised technician conducts the settings.
The list of fans in place is shown in the table:
STOVE MODEL NO. OF FANS
CURVE COMFORT AIR 2
FIG.6
MAN
21:11
FR
OFF
27
23:00
MAX
°C
MAN
21:11
FR
19
SF
°C
MAN
21:11
FR
19
SF
°C
9
11-REMOTE CONTROL MAX
Technical Dept. - All rights reserved - Reproduction is prohibited
Sleep function
The sleep mode allows to quickly set the time at which the product must switch o. This function is only available in MAN and AUTO mode.
It is set as follows: from the POWER setting (by pressing key D - see previous paragraph), press key D again to access the SLEEP mode
setting.
Via key C one can adjust the shutdown time in 10 minute intervals.
By conrming with D or E one goes back to the basic display, in which the sleep mode shutdown time is any case visible (gure 7).
To disable the SLEEP mode simply access the settings, decrease the time until the dashes appear and conrm.
NO AIR FUNCTION (SF)
The NO AIR function allows the stove to operate at the minimum power throughout the night, with no room ventilation. This function is
only available in AUTO and MAN mode(not in TIMER mode). Proceed as follows to set it:
from the VENTILATION setting (by pressing key D), press key D again and you will access theSLEEP setting mode.
From when the dashes “--“ are displayed, press the lower key C and the NO AIR function is activated (SF appears); by conrming with D
or E one goes back to the basic display in which SF and the moon remain visible.
Once the function is activated, the ame power goes to 1 and the ventilation switches o within about 10 minutes.
When this function is active, nothing happens when the C keys are pressed. To disable the NO AIR function, access the SLEEP setting, press
upper key C to make the dashes “--“ appear and conrm with keys D or E.
FIG.7
TIMER
6:30
8:00
MO
TU
WE
TH
FR
SA
SU
ON
OFF
20
P1
°C
TIMER
ECO
OFF ON
10
11-REMOTE CONTROL MAX
TIMER settings
TIMER time slot display
In TIMER mode, to display the time slots simply press key D for 2”. With key C one can scroll the 6 time slots freely, quickly checking the
saved settings (gure 8). By pressing key D or A one goes back to the basic display.
Modifying the TIMER time slots
To modify a time slot, display it as described in the previous paragraph and then press key E. The rst parameter to be set will start to ash,
i.e. room temperature. Press key C to modify the value and key E to conrm and set the next parameter. The parameters of a time slot can
be set in the following sequence:
Room temperature. Can be set between 5° and 35°C. 2 dashes “--” appear if set below 5°C or above 35°C, and if this is conrmed, the
programme is disabled(therefore, the product will not be switched on).
Switch-on time. The value is adjusted in 10 minute intervals (from 00:00 to 23:50)
Switch-o time. The value is adjusted in 10 minute intervals (from 00:10:00 to 24:00).
Days of the week in which the programme is active. Monday (MO) will start to ash, followed by the other days of the week. Use key
C to activate/disable the day. The activated days will be displayed on a dark background. When the Sunday (SU) setting is complete,
press key E to exit the editing page and return to the time slots display.
By pressing key D at any time one exits the time slot editing mode, saving all variations conrmed with key E up to that time, and one
goes back to the time slot display condition.
While by pressing key A (or leaving the keypad idle for 30”) one goes directly to the basic display, saving all variations conrmed with key
E up to that time.
Activating the TIMER-ECO time slots
In ECO mode one can activate up to 6 time slots, customising switch-on and switch-o (E1 – E6): by pressing key D for 2” the TIMER
activation/disabling function will appear (gura 9). If the ON option is conrmed one can display/modify the 6 time slots of the TIMER-
ECO with the same procedure described previously for the TIMER. By conrming the OFF option, the TIMER is disabled and the product goes
back to operate in ECO mode without active time slots.
REMOTE CONTROL SYNCHRONIZATION
When the product is started up for the rst time, it may be necessary to synchronize the new remote control with the stove. To do this,
follow these simple instructions:
connect the socket to the stove and turn on the power switch
make sure the selector D on the emergency panel is in the REMOTE position
when the rst message appears on the emergency panel’s display, use a pointed object to press the chased G button (toothpick, etc.)
the panel’s display will show 3 ashing lines “---“. Press the remote control’s on/o button to launch the learning process.
The three ashing lines will disappear from the display and the stove will learn the remote control’s new communication address.
The learning process is also conrmed by an audio signal.
A
B
C
G
D
E
F
H
11
11-REMOTE CONTROL MAX
Technical Dept. - All rights reserved - Reproduction is prohibited
The emergency panel is found at the back of the stove. The panel is used to detect any malfunctions and also for product control if the
remote control is not working.
KEY
A - DISPLAY; indicates a series of information on the stove, as well
as the identication code of any malfunction.
B - GREEN LED that indicates:
OFF = Stove o
FLASHING ON = Stove in ignition stage
FIXED ON = Stove on
C - RED LED that indicates:
OFF = Stove on
ON WITH SLOW FLASHING = Stove in shutdown stage
ON WITH FAST FLASHING = Stove in alarm conditions
(combined with a beep sound for the rst 10 minutes)
FIXED ON = Stove o
D - Three-position selector for the following functions
OFF = Stove switched o manually without remote control
REMOTE = Stove controlled exclusively from the remote
control
ON = Stove switched on manually without the remote control
E - Three-position selector to select the power
MIN = Selector to make the stove work at MINIMUM power
without the remote control and with selector 4 on ON
MED = Selector to make the stove work at MEDIUM power
without the remote control and with selector 4 on ON
MAX = Selector to make the stove work at MAXIMUM
power without the remote control and with selector 4 on
ON
F - Button for diagnostic functions relating to the operating
status of the stove
G - Button to put the stove in communication with a new remote
control (via the procedure explained in the Remote Control
Synchronisation" paragraph)
H - Reception antenna
SELECTOR "D" MUST BE SET ON "REMOTE" TO
MAKE THE STOVE OPERATE WITH THE REMOTE
CONTROL.
V
A
12
11-REMOTE CONTROL MAX
INSTALLATION OF THE CONTROL PANEL ANTENNA
Take Antenna A from the bag containing the instructions
Tighten Antenna A clockwise on screw V” near the control panel until the mobile part of the antenna is at the top.
Attention! Fully tighten the antenna without forcing it so as to avoid damaging the reception.
I/ON
13
11-REMOTE CONTROL MAX
Technical Dept. - All rights reserved - Reproduction is prohibited
ELECTRICAL CONNECTION
First connect the power cable to the back of the stove and then to a wall socket.
The main switch must only be activated to switch the stove on; otherwise, it is advisable to keep it switched o.
It is recommended to disconnect the power cable when the stove is not used.
The cable must never come into contact with the smoke exhaust pipe or any other part of the stove.
STOVE POWER SUPPLY
After connecting the power cable to the back of the stove, turn the switch to (I) or ON.
The stove is then powered.
There is a fuse box also in the switch block next to the power socket. Open this compartment by simply lifting the cover, using a screwdriver
as a lever from inside the power outlet compartment. Inside there are two fuses (3.15 A delayed), which may need to be replaced if the
stove is not powered (e.g. the ON/OFF button does not go on or the control panel display does not light up) - operation to be implemented
by an authorised and skilled technician.
ELECTRICAL STOVE CONNECTION
STOVE POWER SUPPLY
STOVE SWITCH
FUSE COMPARTMENT
ON
OFF
D
E
14
11-REMOTE CONTROL MAX
Switch-on/o from the emergency panel
If the remote control is faulty or the batteries are at, the product can be operated in safe mode via the rear emergency panel.
In this conguration, the stove can only operate in manual mode and with the possibility to choose between 3 power levels.
SWITCHING THE STOVE ON WITHOUT THE REMOTE CONTROL
To switch the stove on move selector “D to the ON position. The RED LED goes o upon start-up, while the GREEN LED starts to ash until
the start-up stage is complete. Once the product is in steady state, the GREEN LED remains on.
CHOOSING THE POWER WITHOUT THE REMOTE CONTROL
One can choose between 3 heating powers:
MIN-MED-MAX (seletctor “E”)
The MINIMUM power corresponds to the 1
st
power;
The MEDIUM power corresponds to the 3
rd
power;
The MAXIMUM power corresponds to the 5
th
power;
SWITCHING THE STOVE OFF WITHOUT THE REMOTE CONTROL
To switch the stove o move selector “D to the “OFF” position.
Once the remote control is restored, remember to set selector “D” back to the “REMOTE” position, otherwise the
product will ignore the remote control commands.
15
11-REMOTE CONTROL MAX
Technical Dept. - All rights reserved - Reproduction is prohibited
Feed screw loading function
This function can only be activated when the stove is o and allows the pellets to be loaded into the loading system (feed screw). It can
be used each time the pellets nish in the hopper (see alarm A02). It is useful to prevent failed start-ups (alarm A01) due to the hopper
being empty.
Enable the function as follows:
Set the rst selector to OFF
Set the second selector to MED
Make sure that OFF appears on the display because this function can only be activated with the stove completely cold (o) and the
selector set to OFF.
Press the TEST key 3 times consecutively within 2 seconds
“OnPlt” will appear on the display in two subsequent intervals.
Press the TEST key once again when the pellets begin to fall into the brazier to end the FEED SCREW LOADING function or wait for
the function to end alone (approx. 3 minutes).
Proceed with lighting the stove.
16
11-REMOTE CONTROL MAX
Modifying the pellet recipe
This function is for adapting the stove to the type of pellet in use. As there are many types of pellet available on the market, operation of
the stove can vary considerably according to the quality of the fuel.
The amount of pellets in the brazier can be increased or reduced:
If the pellets tend to jam in the brazier due to an excess of fuel
If the ame is increasingly higher even at low power values
• Proceed as follows if the ame is always low in order to change the recipe:
Set the two selectors to OFF (the stove must not be in an alarm status)
Press the TEST button for 5/9 seconds (the stove emits 5/9 beeps)
Release the TEST key
The code PLt appears on the display
Press the chased button to increase or reduce the desired amount of pellets.
Available values:
- 3 = Reduction of pellet loading by 20% at all power values
- 2 = Reduction of pellet loading by 13% at all power values
- 1 = Reduction of pellet loading by 6% at all power values
0 = no change
1 = Increase of pellet loading by 10% at all power values
2 = Increase of pellet loading by 6% at all power values
3 = Increase of pellet loading by 3% at all power values
Press the TEST key once to conrm
17
14-SAFETY DEVICES
Technical Dept. - All rights reserved - Reproduction is prohibited
SAFETY DEVICES
The product is tted with the following safety devices.
SMOKE TEMPERATURE PROBE
It detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset
value.
PELLET HOPPER TEMPERATURE PROBE
If the temperature exceeds the preset safety value, it immediately stops the product, which must cool down before the stove is restarted.
ELECTRICAL SAFETY
The product is protected against power surges by a general fuse located in the control panel on the back. Other fuses that protect the
electronic boards are found on the latter.
SMOKE FAN BREAKAGE
If the fan stops, the circuit board promptly blocks the supply of pellets and the alarm is displayed.
GEAR MOTOR BREAKAGE
If the gear motor stops, the product switches o and the relative alarm is signalled.
TEMPORARY POWER CUT
If a power cut occurs during operation, the product automatically sets itself in cooling mode when the power is restored and then it
restarts.
FAILED START-UP
If no ame lights during start-up, the product will go into alarm conditions.
TAMPERING WITH THE SAFETY DEVICES IS PROHIBITED.
It is possible to relight the product and therefore restore the automatic operation of the probe only after having eliminated the cause of
the intervention of the safety system. This manual will help you understand which anomaly has occurred, and explain how to intervene
according to the alarm message displayed on the appliance.
18
15-ALARMS
ALARM ALERTS
In the event an operating anomaly occurs the stove starts switching o due to the alarm and informs the user of the type of
fault that has taken place via a 3 digit code which stays displayed on the rear emergency panel.
The alarm is indicated permanently by the relative 3 digit code, by a ashing red LED that lights up on the emergency panel and an
intermittent sound signal for the rst 10 minutes of the alarm. Read the instructions in the following 2 paragraphs to cancel the alarm
status and restore the normal operating mode of the stove.
The following table describes the possible alarms indicated by the stove, associated to the respective code that appears on the emergency
panel and helpful tips to solve the problem.
MESSAGE ON DISPLAY TYPE OF PROBLEM SOLUTION
A01
The ame does not light Check the level of pellets in the tank.
Check that the brazier is correctly positioned in its seat
and has no build-up or unburned material.
Make sure the ignition plug warms up.
Thoroughly empty and clean the brazier before restarting.
A02
The ame is goes out unexpectedly Check the level of pellets in the tank.
Check that the brazier rests correctly in its seat and has no
visible deposits of unburned pellets.
A03
The temperature of the pellet hopper
exceeds the required safety threshold.
The structure overheats due to reduced
heat dissipation.
The structure is too hot because the product has been
used for too long at the maximum power or there is
poor ventilation. When the product is suciently cold,
press button B on the control panel or OFF on the remote
control to cancel alarm A03. Once the alarm is cancelled,
the product can be switched on normally.
A04
The temperature of the exhaust smoke has
exceeded certain preset safety limits.
The stove switches o automatically. Let the stove cool
down for a few minutes and then switch it on again.
Check the smoke expulsion and verify the type of pellet
used according to the instructions found in Chap. 2 of this
manual.
A05
Chimney ue clogged - wind - door open. Check the smoke duct and make sure the door is closed.
The smoke extractor fails to guarantee
sucient primary air, required for correct
combustion.
Draught diculties or brazier clogged.
Check whether the brazier is clogged and clean it, if
necessary.
Check and if necessary clean the smoke duct and air inlet.
A08
Abnormal operation of smoke fan Check cleanliness of the fumes fan compartment and
check if dirt is blocking it. If this is not enough, the smoke
fan is faulty. Contact an authorised service centre to have
it replaced.
A09
The smoke probe is faulty and does not
detect the exhaust smoke temperature
properly.
Contact an authorised service centre to have the
component replaced.
A11
Pellet supply fault Contact an authorised service centre to have the
component replaced.
19
15-ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
A13
Electronic control unit overheating The structure is too hot because the product has been
used for too long at the maximum power or there is
poor ventilation. When the stove is suciently cold,
press button B on the control panel or OFF on the remote
control to cancel alarm A13. Once the alarm is cancelled,
the product can be switched on normally.
A14
Faulty air ow rate sensor This alarm does not block the stove, just a warning is
displayed. Contact an authorised service centre to have
the component replaced.
A18
TRIPPED SAFETY
DEVICES
Open stove door Close the door
Open fuel loading hatch Close the hatch. Lower the fuel level in the tank.
Air pressure switch Draught diculties or brazier clogged.
Check whether the brazier is clogged by scaling and clean
it, if necessary.
Check and if necessary clean the smoke duct and air inlet.
SER
Routine maintenance alert When this ashing message appears upon start-up
it indicates that the preset operating hours before
maintenance is due have elapsed and that an MCZ
qualied technician must be contacted for maintenance.
Exiting the alarm conditions
Follow the procedure described below to restore normal stove operation after an alarm has been triggered:
Put selector D on the rear emergency panel on OFF for a few seconds (about 20 seconds), until the 3 digit alarm identity code
disappears. The red LED stops ashing and the sound signal is silenced by performing the steps below.
Put selector D back in the REMOTE position, to control the operation of the stove via the remote control.
Switch o the remote control and switch it on again if one wants to restart the stove.
20
15-ALARMS
Mechanical stove block
The following conditions may cause the mechanical stove block:
Structure overheating (“A03”)
Smoke overheating (“A04”)
During stove operation air has entered the combustion chamber or there is an obstruction in the ue (“A05”)
The block is signalled on the display and with a sound signal. In this situation the shutdown stage is activated automatically.When this
procedure is started, any test operation to restore the system is useless. The display signals the cause of the blockage.
SOLUTIONS:
If “A03 appears: the structure is too hot because the product has been used for too long at the maximum power or there is poor ventilation.
When the product is suciently cold, press button B on the control panel or OFF on the remote control to cancel alarm A03. Once the
alarm is cancelled, the product can be switched on normally.
If “A04 appears: The stove switches o automatically. Let the stove cool down for a few minutes and then switch it on again. Check the
smoke expulsion and verify the type of pellet used according to the instructions found in Chap. 2 of this manual.
If “A05 appears: the door has been left open for too long or a signicant amount of air has entered (e.g. missing smoke fan inspection
cap). If these causes are excluded, check and if necessary clean the smoke duct and ue. (it is recommended that this operation is carried
out by an MCZ qualied technician.
The product can be switched on again only after having eliminated the cause permanently.
21
15-ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
In the event that alarm A18 is triggered often, please note that:
A18
INTERVENTO
SICUREZZE
Porta stufa aperta Chiudere la porta
Sportello di caricamento combustibile
aperto
Chiudere lo sportello.
Abbassare il livello di combustibile nel serbatoio.
Pressostato aria Dicoltà di tiraggio o intasamento del braciere.
Vericare se il braciere è intasato dalle incrostazioni ed
eventualmente pulirlo.
Controllare ed eventualmente pulire il condotto fumario
e l’ingresso dell’aria.
you must check some points to verify the cause of the problem and possibly act on some adjustments and/or safety devices to restore the
correct operation of the product.
However please note that all the adjustments and alterations aecting the operational safety devices, must only be performed if THE
PRODUCT IS INSTALLED IN COMPLIANCE WITH THE STANDARDS AND LAWS IN FORCE AND IF IT IS SERVICED PROPERLY BY AUTHORISED AND
SPECIALISED PERSONNEL. Alterations performed randomly, to ensure operation of the product even in the non-compliant conditions, can
cause serious damage to property and injuries to people. If this occurs, the manufacturer declines all liability
Attention!
The adjustments must only be carried out by authorised and qualied personnel under their responsibility and
by checking the conformity of the installation beforehand. The manufacturer declines all liability for damage to
property or injuries to people in the event of altering the safety devices.
As mentioned alarm A18 identies a drop in pressure inside the product that can be generated by diculty to discharge the fumes (ash
clogging the ue), to draw combustion air (clogged ducting or no air inlet) or by opening some stove compartments (re door or pellet
tank cover)In light of the above, before acting on the safety devices or on any adjustments, you must check in this sequence if there are
any potential malfunctions that may generate the alarm. Therefore check that:
The stove door is closed
The stove door is closed
The installation is compliant and the ue/smoke tting does not generate obvious obstructions which can stop the release of smoke,
such as: long horizontal sections (over 3 metres), uninsulated smoke ducts, “wall-mounted” smoke exhaust without proper terminals
(installation regulated and permitted in France only [ZONE 3])
The minimum depression in the ue is at least 5 Pa
The pellets are of certied quality and do not cause obstructions
There is no ash clogging the ue and the latter is serviced properly.
There are no foreign bodies in the ue (nests, birds, grilles, leaves etc..)
There are no foreign bodies in the combustion air ducting and/or in the room air inlet
When installed without combustion air ducting, it is crucial to check that there is an ecient air inlet dedicated to the stove,
according to the specications referred to in chapter 2 of this manual.
That there are no internal air extraction or recirculation systems (e.g. VMC systems) that generate internal depressions exceeding
those required by law (not exceeding 4 Pa)
That the pressure switch is not damaged or dirty (inspection to be performed by an authorised service centre)
That the stove gasket (re door, pellet tank, etc..) is not worn or damaged. Otherwise contact an authorised service centre for
replacement/repair
Attention!
All liability for improper use of the product is entirely borne by the user and relieves the Manufacturer from any civil
and criminal liability.
22
15-ALARMS
If all the above checks are negative, it is likely that the depression inside the stove drops due to poor performance of the ue, especially
when the machine is operating at minimum speed for a long time.
In this case it is possible to make small adjustments that allow you to increase the operating speed of the smoke fan to increase the
depression inside the product, or make it less sensitive to the intervention of the pressure switch by changing its position mechanically.
While the rst adjustment has no impact on the level of safety, the second one described aects it considerably and therefore should only
be performed by authorised and specialised personnel after carrying out all the inspections mentioned above.
Changing the smoke fan revolutions
In order to further improve combustion in critical conditions, you can change the percentage of the parameters for the minimum amount
of incoming combustion air. These changes can be performed upwards in the event of serious diculties in evacuating smoke and/or air
intake or downwards in the event of excessive draught of the ue.
Set the two selectors to OFF (the stove must not be in an alarm status)
Press and hold down the TEST button. The panel will produce a series of beeping sounds in sequence.
Release the key after 20 to 24 beeping sounds.
The code rAC appears on the display
Press the chased button to change the values
AVAILABLE VALUES
-2 -10%
-1 -5%
0 0% (default value)
+1 + 5%
+2 +10%
Press the TEST key once to conrm
v
H
H
S
H
S
P
45°
H
P
P
H
r
23
15-ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
Changing the position of the pressure switch
ATTENTION!
All the operations must be performed with the product completely cold and the plug disconnected. Disconnect the
product from the 230V power supply before performing any operation.
One can then act on the air pressure switch by changing the installation position. The pressure switch is tted behind the electronic board
of the stove.
To change the position of the pressure switch, which by default is in
an upright position, proceed as described below:
remove the side covering of the stove
remove the back panel of the stove
unscrew the two screws “v and remove the entire block “H”
consisting of a board support, board and pressure switch
remove board “S” from the support
remove screws r that block the pressure switch “P in a vertical
position
Tilt the pressure switch by 45° and use the designated holes to
secure it with screws “r”
reassemble everything
PLEASE NOTE There are two small tubes coming out of the pressure switch, one connected to the pressure transducer and
the other one to the tank. For the shift there is no need to remove this connection, also to avoid reassembly errors.
There might be the need to disconnect some cables when disconnecting the electronic board.
Attention! All the adjustments must be performed solely by authorised and qualied personnel.
24
16-RECOMMENDATIONS FOR SAFE USE
ONLY CORRECT INSTALLATION AND APPROPRIATE MAINTENANCE AND CLEANING OF THE APPLIANCE CAN GUARANTEE
CORRECT OPERATION AND SAFE USE OF THE PRODUCT.
We would like to inform you that we are aware of cases of malfunctioning of domestic pellet-fuelled heating products, mainly due to
incorrect installation and use, as well as inadequate maintenance.
We would like to assure you that all of our products are extremely safe and certied according to European standards of reference. The
ignition system has been tested with the utmost attention to enhance ignition eciency and to prevent any type of problem, even in the
worst operating conditions. In any case, like for any other pellet-fuelled product, our appliances must be installed correctly and undergo
regular periodical cleaning and maintenance to guarantee safe operation. Our studies show us that malfunctioning is mainly due to the
combination of part or all of the following factors:
Brazier holes obstructed or brazier deformed, due to lack of maintenance and conditions which can cause delayed ignitions,
generating an anomalous production of unburned gases.
Insucient combustion air due to a reduced or clogged air inlet duct.
Use of smoke ducts nonconforming to regulatory installation requirements, failing to guarantee an adequate draught.
Partially clogged chimney, due to lack of maintenance, reducing the draught and making ignition dicult.
End chimneypot nonconforming to the indications of the instruction manual, and therefore not suitable to prevent potential inverse
draught.
This factor is crucial when the product is installed in especially windy areas, such as coastal regions.
The combination of one or more of these factors could generate important malfunctioning conditions.
To keep this from occurring, it is fundamental to guarantee that the product is installed in compliance with standards in force.
Furthermore it is of the utmost importance to respect the following simple rules:
Every time the brazier is removed for cleaning, it must always be put back properly in the work position before using the product,
completely removing any residual lth left on the support base.
Pellets must never be loaded in the brazier manually, either before ignition or during operation.
The accumulation of unburned pellets ensuing a failed ignition must be removed before repeating ignition. Also check that they are
fed correctly and that the combustion air inlet/smoke outlet are regular.
If ignition fails repeatedly, immediately suspend use of the product and contact a qualied technician to check its operation.
Compliance with these indications is absolutely sucient to guarantee proper operation and to avoid any type of problems with the
product.
If the above-mentioned precautions are not taken, and during ignition the brazier is overloaded with pellets thus generating anomalous
smoke in the combustion chamber, carefully follow the indications below:
Do not disconnect electrical power to the product for any reason whatsoever: this would stop the smoke extractor, releasing smoke
into the environment.
Take the precaution of opening the windows to ventilate the installation room from any smoke in the environment (the chimney
might not work properly).
Do not open the re door: this would compromise regular operation of the smoke extraction system to the chimney.
Just switch the stove o by acting on the on-o button on the control panel (not the rear power supply socket button!) and move
away until smoke has completely evacuated.
Before attempting re-ignition, clean the brazier and its air passage holes completely of all deposits and unburned pellets. Put
the brazier back in place, removing any residue from its support base. If ignition fails repeatedly, immediately suspend use of the
product and contact a qualied technician to check its operation and the chimney.
T
25
17-CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
Only by properly servicing and cleaning the product is it possible to ensure its safety and correct operation.
CAUTION!
All the cleaning operations of all parts must be performed with the product completely cold and the plug
disconnected.
Disconnect the product from the 230V power supply before performing any maintenance operation.
The product requires little maintenance if used with certied good quality pellets.
DAILY OR WEEKLY CLEANING PERFORMED BY THE USER
Brazier cleaning
Before ignition, always clean the T” brazier and remove any ash or incrustation from it that might obstruct the air ow holes, paying
attention to hot ash. In the case of ignition failure, or if fuel in the tank runs out, unburned pellets may accumulate in the brazier. Always
empty the residue in the brazier before each start-up. You may only use a vacuum cleaner to remove ash when it is completely
cold. In this case, use a suitable vacuum cleaner to remove small sized particles.
EXAMPLE OF A CLEAN BRAZIER EXAMPLE OF A DIRTY BRAZIER
g
26
17-CLEANING
REMEMBER THAT ONLY A CORRECTLY POSITIONED AND CLEAN BRAZIER CAN GUARANTEE SAFE IGNITION AND OPTIMAL
OPERATION OF YOUR PELLET PRODUCT. IN CASE OF FAILED IGNITION AND AFTER ANY OTHER LOCK STATE OF THE
PRODUCT, IT IS ESSENTIAL TO EMPTY THE BRAZIER BEFORE EVERY RESTART.
For the brazier to be cleaned properly, remove it from its housing completely and thoroughly clean all the holes and the grate on the
bottom. If good quality pellets are used, you will normally only need to use a brush to restore the optimal operating conditions of the
component.
Cleaning the ash collection compartment
To clean the ash collection compartment, you must raise grille g” by rotating until it rests against the rebox. Clean out any residual
ash before lowering the grille g”. The quality of the pellets used and user experience will determine the required cleaning frequency.
However, it is recommended not to exceed 2 or 3 days.
CLEANING THE GLASS
It is recommended to clean the ceramic glass with a dry brush, or if it is very dirty, spray a little specic detergent and clean with a cloth.
ATTENTION!
Do not use abrasive products and do not spray the glass cleaning product on the painted parts and on the door
gaskets (ceramic bre cord).
27
17-CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
CLEANING THE AIR FILTER
A wire mesh air lter is found at the back of the stove, whose purpose is to prevent dirt entering the motor body and the internal sensor.
It is recommended to check that the lter is clean every 15/20 days. If needed remove u or the material that has deposited on it.
Inspection and cleaning are required more frequently if there are pets in the house.
Simply remove the lter to clean. To clean it use a brush or a damp cloth or compressed air. Set it back in place by simply pressing it
(interlocks).
The lter is made of metallic mesh and is soft and exible to the touch therefore, when cleaning, be careful not to
crush or damage it. In the event of breakage it must be replaced.
ATTENTION!
Never let the stove work without the air lter tted. MCZ cannot be held liable for any damage caused to the internal
components if this requirement is not complied with.
Z
A
n
o
y
y
28
17-CLEANING
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE HEAT EXCHANGER AND THE LOWER COMPARTMENT
Half-way through the winter season, but especially at the end, the compartment through which the exhaust smoke passes will need
to be cleaned.
This cleaning process is mandatory in order to facilitate the general removal of all combustion residue, before it becomes very dicult to
remove it due to the humidity compacting it over time.
CAUTION:
Cleaning is mandatory to be performed at the end of the season by an authorised and skilled technician so that even
the seals can be replaced.
CLEANING THE LOWER COMPARTMENT
To clean the lower ash compartment, open the doors of the stove and remove bottom panel A, as per instructions in the dedicated
chapter. Use the cold handle to open door “Z” by rotating the designated closure. Then move door “Z” down to the structure of the stove.
Now loosen the four screws “y, remove plate “n” and gasket o”. Use the nozzle of a vacuum cleaner to remove any ash and soot that may
have built up in the lower exchanger (smoke extractor) indicated by the arrow.
Before restoring cap “n we recommend changing the gasket o.
H
H
1
2
3
29
17-CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
CLEANING THE EXCHANGER
CLEANING THE UPPER COMPARTMENT
Clean the upper exchanger when the stove is cold and without the cladding in question. After removing the cap for lower cleaning “n”
(see previous paragraph), use a sti rod or a bottle brush to scrape the rebox walls (see arrow) so that the ash falls into the lower
compartment.
Then remove the upper Calorite plate “H”; to do this, open the rebox door and lift the Calorite plate “H” by tilting it right or left so that it
comes out of its supports and remove it.
H
H
30
17-CLEANING
Use a sti rod or a bottle brush to scrape the rebox walls (see arrow - at the right and left of the rebox respectively) so that the ash falls
into the lower compartment.
Use a vacuum cleaner nozzle to vacuum up any remaining ash and dust on the exchanger (see arrow).
31
17-CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
Also vacuum under the top to remove any accumulated dust.
Then thoroughly clean the lower exchanger, replace any gaskets if needed, and reassemble.
X
32
17-CLEANING
CLEANING THE SMOKE DUCT AND GENERAL CHECKS
Clean the smoke extractor duct, especially around the “T joints, bends and any horizontal sections.
For information on cleaning the ue, contact a chimney sweep.
Check the seal of the ceramic bre gaskets on the door of the stove. If necessary, order new replacement seals from the retailer or contact
an authorized service centre to carry out this task.
CAUTION:
The frequency with which the smoke outlet system is cleaned depends on the use of the boiler and the type of
installation.
We recommend relying on an authorised service centre for end-of-season cleaning and maintenance, as they will
carry out all of the previously mentioned work and inspect the stove components.
PERIODICAL CHECK OF THE DOOR CLOSURE
Make sure the door closure ensures a correct sealing action (with the “paper sheet” test) and that when the door is closed, the closing block
(X in the gure) does not protrude from the sheet metal to which it is secured. For some products it will be necessary to disassemble the
cladding to be able to assess the anomalous protrusion of the block when the door is closed.
33
17-CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
END-OF-SEASON SHUTDOWN
At the end of each season, before switching the product o, it is recommended to remove all the pellets from the hopper with a vacuum
cleaner with a long pipe.
We recommend removing the unused pellet from the tank because it can retain humidity. Disconnect any combustion air ducting that
can lead humidity inside the combustion chamber but, above all, ask the specialised technician to refresh the paint inside the combustion
chamber with the special silicone spray paints (available at any store or CAT) during the necessary annual end of season scheduled
maintenance operations. In this way the paint will protect the inner parts of the combustion chamber, blocking any type of oxidative
process.
When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the
power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again by pressing
the main switch on its side.
There is a fusebox on the side of the product, near the power socket. Open the fusebox cover with a screwdriver and replace the fuses if
necessary (3.15 A delayed) - seek assistance from an authorised and qualied technician.
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualied personnel whose technical expertise
includes combustion and electricity.
We recommend that an annual maintenance service is carried out with a scheduled service contract. This service is essentially a visual and
functional inspection of the following components: The following is a summary of the checks and/or maintenance that are indispensable
for the correct operation of the product.
PARTS/INTERVAL 1 DAY 23 DAYS 15/20 DAYS 1 YEAR
Brazier
Ash pan
Glass
Upper exchanger
Lower exchanger
Smoke duct
Gaskets
Air lter
Remote control battery
Door closure operation
34
18-FAULTS/CAUSES/SOLUTIONS
ATTENTION!
All repairs must only be carried out by a specialised technician, with the product switched o and the plug
disconnected.
ANOMALY POSSIBLE CAUSES SOLUTIONS
The pellets are not fed into the
combustion chamber.
The pellet hopper is empty. Fill the hopper with pellets.
Sawdust has blocked the feed screw. Empty the hopper and remove the sawdust
from the feed screw by hand.
Faulty gear motor. Replace the gear motor.
Faulty circuit board. Replace the circuit board.
The re goes out or the boiler stops
automatically.
The pellet hopper is empty. Fill the hopper with pellets.
The pellets are not fed. See the previous anomaly.
The pellet temperature safety probe has
been triggered.
Let the product cool down, restore
the thermostat until the lockout is o
and switch the appliance back on. If
the problem persists contact Technical
Assistance.
Chrono active. Check if the chrono setting is active.
The door is not closed properly or the
gaskets are worn.
Close the door and replace the gaskets
with original ones.
Unsuitable pellets. Change the type of pellets with those
recommended by the manufacturer.
Low pellet supply. Check the ow of fuel following the
instructions in the manual.
The combustion chamber is dirty. Clean the combustion chamber, following
the instructions in the manual.
Clogged outlet. Clean the smoke duct.
Faulty smoke extraction motor. Check the motor and replace it, if
necessary.
35
18-FAULTS/CAUSES/SOLUTIONS
Technical Dept. - All rights reserved - Reproduction is prohibited
ANOMALY POSSIBLE CAUSES SOLUTIONS
The product works for a few minutes
and then switches o.
Start-up phase is not completed. Repeat start-up.
Temporary power cut. Switch it back on.
Clogged smoke duct. Clean the smoke duct.
Faulty or malfunctioning temperature
probes.
Check and replace the probes.
Pellets accumulate in the brazier, the
glass of the door gets dirty and the
ame is weak.
Insucient combustion air. Make sure that the air inlet in the room is
tted and clear.
Clean the brazier and check that all the
holes are clear.
Perform a general cleaning of the
combustion chamber and the smoke duct.
Check the condition of the door gaskets.
Damp or unsuitable pellets. Change the type of pellets.
Faulty smoke evacuation motor. Check the motor and replace it, if
necessary.
The smoke evacuation motor does
not work.
No electrical supply to the stove. Check the mains voltage and the
protection fuse.
The motor is faulty. Check the motor and capacitor and replace
them, if necessary.
Defective circuit board. Replace the circuit board.
The control panel is broken. Replace the control panel.
The convection air fan never stops. Thermal probe defective or faulty. Check the probe and replace it, if necessary.
Fan faulty. Wait a few minutes and check motor
operation, replace it if necessary.
The product has not reached the shutdown
temperature yet.
Wait.
36
18-FAULTS/CAUSES/SOLUTIONS
ANOMALY POSSIBLE CAUSES SOLUTIONS
The air fan does not switch on. The product has not reached the
temperature.
Wait.
The remote control does not work. The remote control battery is at. Replace the battery.
Remote control faulty. Replace the remote control.
The product always runs at maximum
power when in automatic mode.
The room thermostat is in the maximum
position.
Reset the temperature of the remote
control.
Malfunctioning temperature probe. Check the probe and replace it if necessary.
Faulty or malfunctioning control panel. Check the panel and replace if necessary.
The product does not switch on. No power supply. Check that the plug is inserted and the
main switch is in the “I/ON” position.
Fuse tripped due to a fault. Replace the fuse with one of the same
characteristics (5x20 mm T 3.15A).
Check the brazier. Clean the brazier and remove any deposits
or residues of non-burned pellets.
Check the position of the brazier. Put the brazier back in its place.
Check that the ignition plug warms up. Check and if necessary, replace.
Clogged smoke outlet or smoke duct. Clean the smoke exhaust and/or the
smoke duct.
Faulty ignition plug. Replace the ignition plug.
75
4
9
8
10
13
12
11
2
3
1
6
14
15
+
-
GND
SIGNAL
5V
GND
SIGNAL
5V
GND
SIGNAL
12V
ROSSO
BLU
ALTA TENSIONEBASSA TENSIONE
-
+
GND
12V
37
19-CIRCUIT BOARD
Technical Dept. - All rights reserved - Reproduction is prohibited
COMFORT AIR STOVE WITH 2 FANS WIRING KEY
1. SMOKE FAN ENCODER
2. GEAR MOTOR ENCODER
3. PRESSURE TRANSDUCER
4. SMOKE TEMPERATURE PROBE
5. SOFTWARE UPDATE (USB)
6. MODBUS COMMUNICATION FOR MODEM, WI-FI, ETC.
7. EMERGENCY PANEL
8. HOPPER OVERLOAD CUT-OUT
9. AIR FAN 1
10. GEAR MOTOR
11. SMOKE FAN
12. SPARK PLUG
13. SWITCH
14. AIR FAN 2
15. PRESSURE SWITCH
PLEASE NOTE The electrical wiring of individual components is tted with pre-wired connectors of dierent sizes.
LIVE ELECTRICAL CABLES
DISCONNECT THE POWER SUPPLY CABLE 230V BEFORE CARRYING OUT
ANY OPERATIONS ON THE ELECTRICAL BOARDS
LOW VOLTAGE
HIGH VOLTAGE
08/09/16REV.18901615900
MCZ GROUP S.p.A.
Via La Croce n°8
33074 Vigonovo di Fontanafredda (PN) – ITALY
Telephone: +39 0434/599599 r.a.
Fax: +39 0434/599598
Internet: www.mcz.it
e-mail: mcz@mcz.it
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw MCZ Curve COMFORT AIR bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van MCZ Curve COMFORT AIR in de taal/talen: Engels als bijlage per email.

De handleiding is 3,44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van MCZ Curve COMFORT AIR

MCZ Curve COMFORT AIR Gebruiksaanwijzing en installatiehandleiding - English - 48 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info