PELLET STOVES Chapter 5
INSTALLATION AND USE MANUAL
page 50
Maintenance and cleaning Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited
8.1.3. Cleaning the glass
For cleaning the ceramic glass, the use of a dry brush is recommended,
or if it is very dirty, the special spray detergent, applying a small
quantity then cleaning with a cloth.
ATTENTION!
Do not use abrasive products and do not spray the
cleaning product on the glass of the painted parts or
on the gaskets of the fire door (ceramic fibre cord).
8.1.4. Cleaning of the air filter
At the lower part of the stove, where there is the inlet pipe for
combustion air Ø 5 cm, at the time of installation of the stove a metal
mesh air filter must be inserted to prevent dirt from getting into the
motor body and internal sensor.
It is advisable to check every 15/20 days whether the filter is clean.
Remove lint or any other material which may have been trapped by the
filter.
Checking and cleaning will be required more frequently if there are pets
in the home.
For cleaning, just turn the knob that holds the filter on the air intake
pipe and remove the filter by turning in the direction indicated by the
arrow. Clean it with a brush, damp cloth or compressed air.
The filter is made of metallic mesh. It is soft and
malleable to the touch. Therefore, when cleaning it,
be careful not to crush it or damage it in any other
way. If it is broken it must be replaced
ATTENTION!
Never operate the stove without the air filter. MCZ
shall not be held liable for damage to internal
components if this instruction is not followed.
Removing the air filter for cleaning
Cleaning the glass