5.3. Operation of the remote control
5.3.1. General rules
The product is switched on and off by pressing button A for 1 second.
All modifications are made using button C. Button E is used to confirm
these modifications. Press button B to select the operating mode of the
product (see paragraph 5.5). Use button D to navigate the FAN and
SLEEP setting (see paragraph 5.6).
With the remote control in any status, briefly pressing button A (or not
touching the keypad for 7 seconds) will return you to the basic display.
5.4. Initial settings
5.4.1. Adjusting the time
With the remote control either off or on, pressing buttons B + E for 3
seconds will access the time/ day adjustment setting. The hour figures
will begin to flash and can be modified using button C. Pressing button
E confirms all modifications. The minute figures will then begin to flash.
Follow the same modify/ confirm procedure to move on to the time
display mode (12 h or 24 h) and, lastly, the day will begin to flash.
Confirming this data as well will exit the settings modification.
NOTE: each time the power is reconnected to the remote
control the time will zero and the display will automatically
enter the hour setting.
5.4.2. °C – °F setting.
Press button B for 5 seconds to change the unit of temperature
measurement from Celsius to Fahrenheit and vice versa. Do this only
while the stove is switched off.
5.5. Setting the operating mode
While the remote control is switched on, button B allows you to set one
the four following operating modes of the product. Figures 1, 2, 3 and
4 show the four basic displays, respectively:
Manual, Automatic, Timer and Eco modes
5.5.1. MANUAL mode (indicated by MAN)
In this mode you can manually set the power of the flame (5 levels -
use button C to directly modify) and the ventilation (5 levels + auto)
(see paragraph 5.6.1). Figure 1
5.5.2. AUTOMATIC mode (indicated by AUTO)
In this mode you can set the desired room temperature and the stove
will automatically modulate the power of the flame to reach this
temperature. The ventilation can be adjusted to 5 levels + auto (see
paragraph 5.6.1). Figure 2
FIG.2