28
4-LCD REMOTE CONTROL
TIMER SETTINGS
DISPLAYING THE TIMER TIME BANDS
Simply press key D for 2” to display the time bands in TIMER mode. The 6 time bands can be scrolled through with key C, thereby verifying
all the saved settings. Press key D or A to return to the initial display.
MODIFYING THE TIMER TIME BANDS
Modify a time band by displaying it as described in the previous paragraph and then press key E briey.
The rst parameter that can be set will start to ash, i.e. the room temperature. Press key C to modify the value and key E to conrm and
move on to the next parameter. The parameters of a time band can be set in the following order:
• Room temperature. Can be set between 5° and 35°C. 2 dashes “--” appear if set below 5°C or above 35°C, and if this is conrmed, the
program is deactivated (therefore, the product will not be switched on).
• Start-up time. The value is adjusted in 10 minute intervals (from 00:00 to 23:50).
• Shutdown time. The value is adjusted in 10 minute intervals (from 00:10:00 to 24:00).
• Days of the week when the program is to be activated. Monday (MO) will start to ash, followed by the other days of the week. Use
key C to activate/deactivate the day. The activated days will be displayed on a dark background. When the Sunday (SU) setting is
complete, press key E to exit the editing page and return to the time bands display.
Press key D at any time to save all the changes made (conrmed by pressing key E), exit the time band editing page and return to the
time bands display.
Press key A (or leave the keypad idle for 30”) to go directly to the initial display, saving all the changes made and conrmed with key E.
ACTIVATING THE TIMER-ECO TIME BANDS
6 customised start-up and shutdown time bands (E1 – E6) can be activated in the ECO mode: press key D for 2” and the TIMER activation/
deactivation function will appear. If the ON option is conrmed, the 6 TIMER-ECO time bands are accessed and can be modied as
described earlier on for the TIMER. If the OFF option is conrmed, the TIMER is disabled and the product returns to the ECO mode with
no time bands activated.