5. I can’t access the Internet from the Cable Gateway.
Check if both ends of the network cable and power adapter are properly
connected. Check if the status LEDs on the front panel are functioning
properly.
If using Windows 95, 98 or Me, check the TCP/IP setup on the client side.
Run winipcfg by clicking on the Start button, selecting Run, and typing
winipcfg in the Run field. Press Enter. The PC should have an IP address
of 192.168.0.xxx (“xxx” is from 2 to 254.). The Subnet Mask is
255.255.255.0; the default gateway IP should be the Cable Gateway’s IP
Address, and check that the DNS is correct.
Check the same setup values in the Cable Gateway’s Summary page.
6. When I enter a URL or IP address, I get a time out error.
Check to see if your other PCs work. If they do, verify that your PC’s IP
settings are correct (IP address, Subnet Mask, Default Gateway, and
DNS)
If the PCs are configured correctly, but still not working, check the Cable
Gateway. Make sure that it is connected and ON. Connect to it and check
its settings. (If you cannot connect to it, check the LAN and power con-
nections.)
If the Cable Gateway is configured correctly, check your Internet connec-
tion to see that it is working correctly.
Manually configure the TCP/IP with a DNS address provided by your ISP.
What is the maximum number of IP addresses that the Cable Gateway will sup-
port? The Cable Gateway will support up to 253 IP addresses.
Does the Cable Gateway support IPSec Pass-Through? Yes, it is a feature built
into the Cable Gateway.
Does the Cable Gateway support IPX or AppleTalk? No. TCP/IP is the only proto-
col standard for the Internet and has become the global standard for commu-
nications. IPX, a NetWare communications protocol used only to route mes-
sages from one node to another, and AppleTalk, a communications protocol
used on Apple and Macintosh networks, can be used for LAN to LAN con-
nections, but those protocols cannot connect from WAN to LAN.
47
Cable Gateway
Instant Broadband
®
Series
46
Frequently Asked Questions
Appendix A:Troubleshooting
This section provides possible solutions to problems regarding the Cable
Gateway’s installation and operation. If your situation is described here, the
problem should be solved by applying the corresponding solution. If you can’t
find an answer here, check the Linksys website at www.linksys.com.
1. The Cable Gateway is not working.
Verify that the Power cord and other network cables are plugged in.
Check the LAN and Cable Modem - Cable LEDs on the Cable Gateway’s
front and verify that they are lit appropriately.
Check the settings on your PC.
Check the Cable Gateway’s settings.
2. I can’t connect to the Cable Gateway.
Verify that the Cable Gateway is properly installed; LAN connections are
OK, and it is powered ON.
Make sure that your PC and the Cable Gateway are on the same network
segment. If you are not sure, initiate the DHCP function, and let the PC
get the IP address automatically.
Make sure that your PC is using an IP address within the default range of
192.168.0.2 to 192.168.0.254 and thus compatible with the Cable
Gateway default IP Address of 192.168.0.1
Also, the Subnet Mask should be set to 255.255.255.0 to match the Cable
Gateway. For the Cable Gateway, you can check these settings by using
Control Panel-Network to check the Properties for the TCP/IP protocol.
3. The Diag LED stays lit when it shouldn’t.
The Diag LED lights up when the device is first powered up. The system
will boot up itself and check for proper operation. After finishing the
checking procedure, the LED turns off to show the system is working
fine. If the LED remains lit after this time, the device is not working prop-
erly. Contact your cable provider if this problem persists.
4. The Cable Link LED will not go solid.
Verify that the coaxial cable is firmly plugged into the Cable Gateway’s
cable port, with the other end plugged directly into the Cable wall jack.
Verify that your Cable account is active.
Common Problems and Solutions
27

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Linksys BEFCMUH4 Cable Gateway bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Linksys BEFCMUH4 Cable Gateway in de taal/talen: Engels als bijlage per email.

De handleiding is 0,81 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info