646836
18
Verklein
Vergroot
Pagina terug
1/20
Pagina verder
029.020A / Rev 0508-GB
GB
Operation manual
ZipLevel
ENGLISH
2
ENGLISH
ZipLevel
3
ENGLISH
ZipLevel
Professional precision altimeter
The ZipLevel is a professional altimeter which enables you to scale and level
on your own also around corners with accuracy within 3 mm. You have
a working area up to + 6 m vertical and up to 70 m, respectively 50 m
(with ZipLevel 25) in diameter. The digital measuring module shows all your
measurements and is easy to operate. The extremely sturdy measurement
cable with patented gas-liquid-system reliably works from -30 °C up to
+70 °C.
Warranty
The warranty period is 2 years from the date of purchase. The warranty
covers all material or manufacturing defects occurring during this time. The
following are excluded from warranty: Damage due to improper use (e.g.
operation with wrong type of current/voltage, connection to unsuitable
power source, fall onto hard surface, etc.) or improper storage, normal
wear and tear, and defects which only insignificantly impair the value or
suitability for use. Any tampering by unauthorised persons will render this
warranty void. In the event that you need to claim warranty, please take
the complete device together with all information and the invoice to one
of our dealers or send it in to Umarex-Laserliner.
Accessories: Only with the ZipLevel Pro 35 sensing device, cover and
ground spikes are included. For the ZipLevel 25 these accessories are also
available!
4
ENGLISH
ZipLevel
A Cable reel
B Securing points
C Measurement line
D Measuring module
E Battery compartment (back)
F Room for measuring module
G Pocket for operation manual
H Protective cap
Backside:
I Sensing device (ZipLevel Pro 35)
J Ground spikes (ZipLevel Pro 35)
A
C
B
D
E
F
G
H
I
J
Inserting batteries into the measuring module:
Open the battery compartment (E) and insert the batteries according to
the installation symbol. Pay attention to the correct polarity. Close the
battery compartment again. Remove the protective cover (with ZipLevel
Pro 35 only).
Advice: Do not put used batteries into the household rubbish. They can
be handed in at a collecting point for old batteries respectively hazardous
waste
ENGLISH
ENGLISH
5
ENGLISH
Console:
The keys HOLD and ON/OFF react instantaneously, all the other keys have
to be pressed for 2 seconds in order to activate or deactivate the particular
function. The functions are also fitted with audible signals (clicking and
bleeping) which makes it easier to work overhead or in non visible areas.
Important:
The ZipLevel memorizes the last accomplished function. When you turn the
instrument on again and intend to leave the function, press the accordant
key for 2 seconds.
Hold the
Function keys
for 2 seconds!!!
ZipLevel
6
ENGLISH
ZipLevel
Quick start of the ZipLevel
Open the bottom protective cap of the basic unit and remove the measu-
ring module. Lay the basic unit on the floor with the back facing down.
Slowly pull a sufficient length of line off the cable reel. The altitude will be
transferred from the basic unit to the measuring module.
Switch the measuring module on with the ON/OFF-key and put the unit
with its back or base on the required place of reference. When the display
is ready, you will hear 2 short audible bleeps. Press the ZERO-key for 2
seconds. Keep the measuring module steady until the figure zero appears
on the display. The appliance has now been set.
ADVICE: If the basic unit gets moved, the measuring module needs to be
set at the place of reference again.
Back facing
down!
Base
Back
ENGLISH
ENGLISH
7
ENGLISH
Quick start of the ZipLevel
Give a place of reference to the measuring module (press ZERO-key) and
move it to a different height. The appliance shows the difference in height
between the place of reference and the measuring point. Now you can
hold the appliance against any point and it always shows you the current
height towards the place of reference.
Always use the measuring module with the side, which was used to set
ZERO. Do not change from one locating side to another without setting to
ZERO again.
If you want to find out the height between floor and ceiling set the app-
liance to ZERO with its back or bottom side on the floor. Then hold the
top, base or back to the ceiling in order to measure. Manually add the
height (8,8 cm) or thickness (5,0 cm) of the measuring module to the
shown data. Take into account whether you are working with protective
cover or not! This feature can also be done automatically with the ADDER-
function (pp. 16-17).
ZipLevel
reference point
measuring point
Typical uses:
8
ENGLISH
ZipLevel
Keys and functions
ON/OFF
With this key you switch the unit on and off. If no key has been pressed or
the measuring module has not been moved within 4 minutes, the unit will
switch itself off automatically. After 3 minutes without any activity the unit
will sound a warning by giving 2 long bleeps.
HOLD
The HOLD-function is used where you have problems reading the display
or where you intend to keep the measured data. The function can be
switched on and off by shortly pressing the HOLD-key.
Measuring and keeping of the data (see drawing p. 7):
1) First you set the unit at the required point with the
ZERO-key.
2) Shortly press the
HOLD-key as long as the measuring module is still
being moved. The unit will then give a series of bleeps.
3) Move the measuring module to the place where you intend to measure.
4) Wait until the unit has stabilized and therefore no more bleeps are
audible.
5) Retrieve the measuring module. The data of the remote point will be
kept on the display. Shortly press HOLD again to leave this function.
ENGLISH
ENGLISH
9
ENGLISH
Examples for the HOLD-function:
ZipLevel
ZERO
Press the ZERO-key for 2 seconds in order to make the present height
(location of the measuring module) the point of reference. The unit must
not be moved in this process!
3 m
Level of reference
New level of reference
1. ZERO
2. Press HOLD
When set zo zero
at the top
- 3 m will be shown
at the bottom
10
ENGLISH
ZipLevel
SCALE
With this you choose the required measurements in millimetres, centime-
tres or meters. Press the SCALE-key for 2 seconds and hold. Now the
gauges the bottom right of the display will change. Release the key once
the required measurement appears. The measurement for millimetres is not
indicated, cm and m appear on the display.
RES
The ZipLevel is featured with a choice of 3 display accuracies. Press the
RES-key for 2 seconds and keep it pressed in order to choose the required
resolution. Release the RES-key once the required resolution is shown.
Your choice is stored now up to next accuracy change.
0,2 cm: for highest accuracy
needs more time to stabilize
0,5 cm: for medium accuracy
needs less time for stabilization
1 cm: for rough measuring
quick stabilizing of the results
ENGLISH
ENGLISH
11
ENGLISH
REC
The ZipLevel can also be used for different calculations and shows an
average, minimum and maximum.
1) Press the REC-key for 2 seconds. The word ‘REC’ appears on the left
side of the display.
2) Stabilize the measuring module on the first measuring point and shortly
press HOLD to keep the data. After that you hear a series of bleeps.
Wait until these are finished before you move the module to the next
measuring point.
3) Shortly press the
REC-key to show the average as well as the highest
and bottom rate of the series of measurements. After shortly pressing
the REC-key the letters ’AVG’ (average), ‘MIN’ and ‘MAX’ will be shown
on the display.
4) Press the REC-key for 2 seconds to leave this function. The calculated
figures remain saved until you press the HOLD-key after recalling the
REC-function.
ZipLevel
Value display
12
ENGLISH
ZipLevel
MARK
With the MARK-function you can produce tones to indicate the following
states: a) a chosen height, b) height within a defined scope or c) height
beyond a defined scope.
1) Start of this function:
Get the measuring module into the required
height and press the MARK-key for 2 seconds. Keep the unit steady
until double lines for the scope are blinking on the display and choose
a), b) or c).
a) Produce a tone at a chosen height:
Shortly press MARK and keep the unit steady to set up the tone.
b) Produce a tone
within a defined scope:
Move the measuring module half a scope under the chosen height.
Shortly press MARK and hold the unit steady to set up the tone.
c) Produce a sound
beyond a defined scope:
Move the measuring module half a scope above the chosen height.
Shortly press MARK and hold the unit steady to set up the tone.
Advice: If you want to leave the MARK-function early, shortly press MARK
and ON/OFF at the same time.
ENGLISH
ENGLISH
13
ENGLISH
Define scopes:
a) Tone at a certain height: for accurate levelling
ZipLevel
MARK
Tone
Tone
No tone
No tone
Scope
No tone
Continuous
tone
Bleeping tone
Scope
b) Tone within a scope: for less accurate levelling
MARK
MARK
c) Tone beyoned a scope:
for rough levelling
14
ENGLISH
ZipLevel
CAL
The appliance has been calibrated at the factory. Please only calibrate, in
case the measuring results are wrong or the letters ‘CALare blinking on
the display. A benchmark of 1.219 m above the base unit is important for
the gauging. It will be best to use the sensing device to gauge the app-
liance (only with ZipLevel Pro 35).
Calibrating the ZipLevel:
1) Put the basic unit on its back onto a level surface and switch the
measuring module on.
2) Lay the measuring module on its base or back next to the basic unit.
Press the CAL-key for 2 seconds.
3) When
(0) is blinking on the display, shortly press CAL.
4) When
(1.219) is blinking on the display, raise the measuring module
to a height of 1.219 m above the basic unit and press CAL again. The
measuring module has to be held stable during the process. The sen-
sing device (only with ZipLevel Pro 35) or a measuring marking should
be used as a calibration device.
5) When the display stops blinking and shows 1.219 m the appliance is
recalibrated.
Advice: You can leave the calibration function at any time without calibra-
ting! For that you press the CAL-key for 2 seconds.
ENGLISH
ENGLISH
15
ENGLISH
ZipLevel
Calibration in 3 steps:
Step 1: Lay the measuring module on its base or back next to the basic
unit and press the CAL-key again. (0) is blinking on the display.
Step 2: Press
CAL again. (121.9) is blinking on the display.
Step 3: Lift to a height of 1.219 m and press
CAL again. Hold steadily
during the process. Then (121.9) is shown on the display.
1,219 m
Step 1 Step 2 Step 3
16
ENGLISH
ZipLevel
ADDER (add):
To carry out accurate measurements indoors, the ADDER-function automa-
tically adds the height, respectively thickness of the measuring module on
the measured data.
Advice about the protective cover (only with ZipLevel Pro 35):
You need to state whether you are working with or without protective
cover (‘Boot on’/’Boot off’). Press HOLD to keep the data.
Then press CAL-key for 2 seconds and hold. Display alternately shows
‘bon’ and ‘boff’. Release at either ‘Boot on’ or ‘Boot off’. Press HOLD
again to leave this function. This choice is saved for further measuring!
Access to the ADDER-funktion:
1) Set the required point of reference with the ZERO-key.
2) Press
HOLD and move the measuring module to the required measu-
ring point (e.g. from the floor to the ceiling). You hear short bleeps.
Keep the measuring module stable on the measuring point. The bleeps
will stop when the figure is configured.
3) Now press the
MARK-key to add the height of the measuring module
or press the REC-key for 2 seconds to add the thickness of the measu-
ring module.
Press the HOLD-key to leave the function.
ENGLISH
ENGLISH
17
ENGLISH
ZipLevel
„Boot on“ / „Boot off“:
8,8 cm or
9,4 cm with cover
5 cm or
5,6 cm with cover
Base Back Base Back
ZERO
HOLD
CALHOLD
Choose „Boot on“
or „Boot off“!
MARK
+ Height
REC
+ Thickness
ZERO
HOLD
2 seconds
1.
2.
3.
1.
2.
3.
ADDER-function:
+ +
18
ENGLISH
ZipLevel
TIPS FOR USERS
1) Check the point of reference often when carrying out critical/serious
levelling jobs or press ZERO often at the point of reference. (CAL is not
necessary for levelling!) Hold the height differences between line, basic
unit and measuring module as low as possible.
2) If possible, avoid high differences in temperature between line and
measuring module (e.g. sun and shade).
3) Avoid unnecessary kinks over objects.
4) Avoid pulling hard, whipping or stepping on the line without checking
the point of reference or setting to zero.
5) The display blinks ‘
8888‘ at use beyond the specified altitude range.
Beyond the temperature range under -30 °C or over +70 °C CAL’ is
continuously shown.
6) As the ZipLevel shows the last carried out function when switched on,
please make sure that you leave the function after every measuring.
Hold the relevant key for 2 seconds and you leave the function.
7) Wischen Sie bei matschigen Bedingungen die Messleitung vor dem
Aufwickeln mit einem Tuch ab.
8) Does
--0-- respectively „CAL“ show up, press the ZERO-key as soon as
possible respectively calibrate the appliance.
ENGLISH
ENGLISH
19
ENGLISH
ZipLevel
Technical facts
Vertical measuring range
12 m (6 m over and under the
basic unit)
Horizontal measuring range + 35 m ZipLevel Pro 35 (70 m Ø)
+ 25 m ZipLevel 25 (50 m Ø)
Levelling precision 3 mm
Height-measuring accuracy 0,2 % of the shown data up to
3 m, resp. 0,35 % of the shown
data over 3 m
Scale/measurements mm, cm, m
Saving of data and setting
unlimited, even without battery
Shock-resistance
dropping test on concrete
Measuring module 1,5 m
Basic unit 0,9 m
Water resistance Rain proof; must not be immersed
Operating time 9 V Block 60 operating hours
Weight 3,5 kg
Working an storing temperature -30°C ... + 70°C
UMAREX GmbH & Co. KG
– Laserliner
Donnerfeld 2
D-59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
Service- and shipping address:
UMAREX GmbH & Co. KG
– Laserliner
Möhnestraße 149,
D-59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
laserliner@umarex.com
ZipLevel
18

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Laserliner ZipLevel bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Laserliner ZipLevel in de taal/talen: Engels als bijlage per email.

De handleiding is 0,78 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Laserliner ZipLevel

Laserliner ZipLevel Gebruiksaanwijzing - Nederlands - 20 pagina's

Laserliner ZipLevel Gebruiksaanwijzing - Deutsch - 20 pagina's

Laserliner ZipLevel Gebruiksaanwijzing - Français - 20 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info