680888
1
Verklein
Vergroot
Pagina terug
1/1
Pagina verder
MOUNTING AND CONNECTING THE DEVICE
TECHNICAL DETAILS
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111716/0518
Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
Power consumption Max. ca. 18 W
Environment Temperature range 0–40 °C; humidity 0–95 %; non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; measures
210 x 45 x 140 mm (W x H x D)
Number of fans One quiet fan
Interfaces
WAN: VDSL2 a VDSL2 as per ITU G.993.2; proles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b
a VDSL2 vectoring as per ITU G.993.5 (G.vector)
a Compatible to VDSL2 from Deutsche Telekom
a VDSL Supervectoring as per ITU G.993.2 (Annex Q)
a Compatible to U-R2 from Deutsche Telekom (1TR112)
a ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1
a Supports just one virtual connection at a time in ATM (VPI-VCI pair)
Wi-Fi a Frequency band: 2400-2483.5 MHz (ISM) or 5150-5825 MHz (restrictions vary between
countries)
a Radio channels 2.4 GHz: Up to 13 channels, max. 3 non-overlapping (2.4-GHz band)
a Radio channels 5 GHz: Up to 26 non-overlapping channels (channels available vary
according to country regulations; DFS for automatic dynamic channel selection required)
ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically
disabled in the LCOS conguration.
USB USB 2.0 hi-speed host port for connecting USB printers (USB print server),
serial devices (COM-port server) or USB drives (FAT le system)
ISDN 1 / ISDN 2 ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to
the settings, connect the light-blue ISDN cable either to the NTBA or the ISDN terminal device.
ISDN 2: Internal (NT) ISDN bus. Use the light-blue ISDN cable to connect the ISDN device to
the ISDN interface.
Analog 1 / Analog 2
Analog 3 / Analog 4
Use the cable of your analog devices to connect them with the analog interfaces. If necessary,
use the enclosed adapter.
Cong (Com) / V.24 Serial conguration interface/COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable for
optional connection of analog/GPRS modems. Supports internal COM-port server and provides
transparent asynchronous serial-data transfer via TCP.
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
DHCP), RIP-1, RIP-2, VLAN
ISDN DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD
Declaration of Conformity
Hereby, LANCOM Systems declares that this radio equipment is in compliance with Directive 2014/53/EU. The full text
of the EU declaration of conformity is available at the following internet address: www.lancom-systems.com/ce/
Package content
Manual Quick Reference Guide (DE/EN); Installation Guide (DE/EN)
Cable 1 Ethernet cable, 3 m (kiwi colored connectors); 1 DSL cable for an IP-based line, 4.25 m;
1 ISDN cable, 3 m (light-blue connectors)
Adapters 4 TAE adapters (RJ11 - TAE), 2 RJ11 twin adapters
Power adapter External power supply adapter (230 V); NEST 12 V / 2 A DC/S; barrel / bayonet (EU),
LANCOM item no. 111303
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
i VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, ashing VPN connecting
e ISDN
Off Interface deactivated
Green, permanently D-channel active
Green, ickering ISDN data transfer
Red, ickering ISDN transfer error
Red / orange, blinking ISDN hardware error
b Online
Off WAN connection inactive
Green, permanently WAN connection active
Red, permanently WAN connection error
c DSL
Off Interface deactivated
Green, permanently DSL connection active
Green, ickering DSL data transfer
Red, ickering DSL transfer error
Red / orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
Green, blinking DSL connecting
d Analog
Off Interface deactivated
Green, permanently Interface activated
Orange, blinking Incoming call
Green, blinking Connection active
h VoIP
Off No SIP accounts dened or VCM is off
Green, permanently All dened and active SIP accounts
(outgoing) were successfully registered
Red, permanently Not all dened and active SIP accounts
were registered (possibly still in process)
Red or green,
inverse ashing
Number of currently used lines (connecting
or connected)
f ETH
Off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
g WLAN
Off No Wi-Fi network dened or Wi-Fi module
deactivated. The Wi-Fi module is not
transmitting beacons.
Green, permanently At least one Wi-Fi network is dened and
Wi-Fi module activated. The Wi-Fi module
is transmitting beacons.
Green, blinking DFS scanning or other scan procedure
j Reset
Reset button Operated e.g. with a paper clip
a short press: Restart the device
a long press: Reset the device
a Power
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Red / green blinking Conguration password not set. Without a
conguration password, the conguration
data in the device is unprotected.
Red blinking Charge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
4
Please observe the following when setting up the device
A Do not rest any objects on top of the device
A For devices to be operated on the desktop, please attach the
adhesive rubber footpads
A In case of wall mounting, use the drilling template as supplied
A Keep the ventilation slots on the side of the device clear
of obstruction
A Rack installation with the optional LANCOM Rack Mount
(separately available)
LANCOM 1681V
Power
VDSL
Online
ETH 1
ETH 2
VPN
ETH 3
ETH 4
ISDN Status
a
VDSL interface
Use the supplied DSL cable for the IP-based line to connect the
VDSL interface and the provider’s telephone socket. For more
infor mation, please contact your Internet service provider.
b
Ethernet interfaces
Use the cable with the kiwi-colored connectors to connect one of
the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
c
Analog interfaces
Connect analog terminal devices to the analog interfaces either
directly via RJ11, or with the help of the enclosed TAE adapters,
either directly or via the additionally enclosed RJ11 twin adapters.
d
Conguration interface
Use a serial conguration cable to connect the serial interface
(COM) to the serial interface of the device you want to use for
conguring / monitoring (separately available).
e
ISDN interfaces
ISDN 1:
Internal (NT) or external (TE) ISDN bus.
This feature is controlled by LCOS.
ISDN 2:
Internal (NT) ISDN bus.
A 100-Ohm resistor for line termination is
switchable in LCOS.
f
USB interface
You can use the USB interface to connect a USB printer or a
USB memory stick.
g
Power
After connecting the cable to the device, turn the bayonet
connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
a b c d e f
g
Gigabit Ethernet 10/100/1000
ISDN 1 ISDN 2
TE / NT NT
VDSL
Analog 1/3Analog 2/4
a c eb gfd ih j
LANCOM R883+
Quick Reference Guide
Cloud-ready
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Lancom R883 plus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Lancom R883 plus in de taal/talen: Engels als bijlage per email.

De handleiding is 0,53 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Lancom R883 plus

Lancom R883 plus Snelstart handleiding - Deutsch - 1 pagina's

Lancom R883 plus Installatiehandleiding - Deutsch - 20 pagina's

Lancom R883 plus Installatiehandleiding - English - 17 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info