TECHNICAL DATA
Hardware
Power supply Internal power supply unit (110–230 V, 50–60 Hz)
Power consumption 40 W
Environment Temperature range 5–40 °C; humidity 0–95 %; non-condensing
Housing Robust metal housing, 19“ 1U with removable mounting brackets, network connectors on the
front
Number of fans 3
Interfaces
ETH 4 individual 10 / 100 / 1000-Mbps Gigabit Ethernet ports (ETH 1 - ETH 4); 1x Gigabit Ethernet
port (ETH 5). Up to 4 ports can be switched as additional WAN ports with load balancing.
Ethernet ports can be electrically disabled within LCOS conguration.
USB USB 2.0 Hi-Speed host port for connecting USB printers (USB print server) or USB data media
(FAT le system); bi-directional data exchange is possible (max. 480 Mbps)
Serial Interface Serial conguration interface
WAN protocols
Ethernet PPPoE, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and plain Ethernet (with or without DHCP),
VLAN, IP
Declaration of conformity
Hereby, LANCOM Systems declares that this device is in compliance with Directives 2014/30/EU and 2014/35/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE, EN), Installation Guide (DE/EN)
Accessories 2 Ethernet cables, 3 m (kiwi colored connectors); 1 serial conguration cable 1.5 m;
1 IEC power cord 230 V (not for WW devices); 1 grounding screw
MOUNTING AND CONNECTING THE DEVICE
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111748/0718
LANCOM ISG-1000
Quick Reference Guide
Cloud-ready
a
USB interface
You can use the USB interface to connect a USB printer or a USB
storage device.
b
Serial conguration interface
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
c
SFP / TP Ethernet interfaces (combo ports)
Insert suitable SFP modules into the SFP ports. Choose cables com-
patible with the SFP modules and connect them as described in the
module’s documentation. SFP modules and cables are not included.
d
If desired, alternatively connect the ETH 1 - ETH 4 TP Ethernet inter-
faces to your PC or a LAN switch using one of the enclosed cables
with the kiwi-colored connectors.
e
TP Ethernet interface
Use one of the enclosed cables with the kiwi-colored connec-
tors to connect the interface ETH 5 to your PC or a LAN switch.
f
Reset button
Pressed up to 5 seconds: device restart
Pressed until rst ashing up of all LEDs:
conguration reset and device restart
g
Power connector and grounding point (device back side)
Supply power to the device via the power connector. Please
use the IEC power cable supplied (separately available for WW
devices).
Warning! High touch current.
Connect to earth before
connecting the power supply.
7
8
h
ATTENTION: High touch current possible! Connect to earth
before connecting the power supply. For this purpose, remove
the existing blind screw and use the enclosed grounding screw
instead.
4
Please observe the following when setting up the device
A The mains plug of the device must be freely accessible.
A For devices to be operated on the desktop, please attach the adhesive rubber
footpads.
A Do not rest any objects on top of the device and do not stack multiple devices.
A Keep the ventilation slots on the side of the device clear of obstruction.
A Mount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.
RESET
COMUSB
TEMP
POWER
ETH 5
ETH 3
ETH 4
ETH 1
ETH 2
LANCOM ISG-1000
a
b c d
e
c d f
RESET
COMUSB
TEMP
POWER
ETH 5
ETH 3
ETH 4
ETH 1
ETH 2
LANCOM ISG-1000
a
b c
ed d
e f
d ETH 1 - ETH 4 - TP (one green and orange LED each)
Both LEDs off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
b TEMP
Green, permanently CPU temperature OK
Red, blinking Hardware failure of the fan or CPU
temperature too high; additional acoustic
signal
e ETH 1 - ETH 4 - SFP (one green and orange LED each)
Both LEDs off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
a POWER
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Green / red, blinking No password set. Without a password
the conguration data in the device is
unprotected.
Red, blinking Charge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
c LCD display (rotating in two lines)
A Device name
A Firmware version
A Device temperature
A Date and time
A CPU load
A Memory usage
A Number of VPN tunnels)
A Data transfer in reception direction
A Data transfer in transmission direction
f ETH 5
Both LEDs off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Lancom ISG-1000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Lancom ISG-1000 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,34 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Lancom ISG-1000

Lancom ISG-1000 Snelstart handleiding - Deutsch - 1 pagina's

Lancom ISG-1000 Installatiehandleiding - Deutsch - 17 pagina's

Lancom ISG-1000 Installatiehandleiding - English - 17 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info