703321
1
Verklein
Vergroot
Pagina terug
1/1
Pagina verder
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111655/0218
TECHNICAL DETAILS
MOUNTING AND CONNECTING THE DEVICE
*) The additional power LED statuses are displayed in 5-seconds rotation
if the device is congured to be managed by the LANCOM Management
Cloud.
This product contains separate open-source software components which are subject to their own licenses, in particular the
General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s WEBcong
interface under “Extras > License information“. If the respective license demands, the source les for the corresponding software
components will be made available on a download server upon request.
4
Please observe the following when setting up the device
A The mains plug of the device must be freely accessible.
A For devices to be operated on the desktop, please attach the adhesive rubber
footpads
A Do not rest any objects on top of the device and do not stack multiple devices
A Keep the ventilation slots on the side of the device clear of obstruction
A Mount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.
Pay attention to the “R” and “L” marks on the brackets for accurate mounting.
POWER
POWER
a c eb fd
a VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, ashing VPN connecting
e ISDN 1 (TE/NT) / ISDN 2 (NT)
Off Interface deactivated
Green, permanently D-channel active
Green, blinking ISDN connection active
Orange, blinking ISDN connecting
Green / orange, blinking
synchronously
ISDN hardware error
Orange, permanently Connection inactive
a POWER
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Green / red, blinking No password set. Without a password
the conguration data in the device is
unprotected.
Red, blinking Charge or time limit reached
1x green inverse blinking* Connection to the LMC active, pairing OK,
device not claimed
2x green inverse blinking* Pairing error, resp. LMC activation code not
available
3x green inverse blinking* LMC not accessible, resp. communication
error
c VDSL 1 / VDSL 2
Off Interface deactivated
Green, blinking DSL connecting
Green, permanently DSL connection active
Green, ickering DSL data transfer
Green / orange, ickering DSL transfer error
Green / orange, blinking
synchronously
DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
a VoIP
Off No SIP accounts dened or VCM is off
Green, permanently All dened and active SIP accounts
(outgoing) were successfully registered
Red, permanently Not all of the dened and active SIP accounts
were registered (possibly still in process)
Red or green, inverse
ashing
Number of currently used lines
(connecting or connected)
e ETH 1 - ETH 4
Green, orange off No networking device connected
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
d WAN 1 / WAN 2
Green, orange off No networking device connected
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
b RESET
Reset button short press > Restart the device
long press > Reset the device
Hardware
Power supply Internal power supply unit (100–240 V, 50-60 Hz)
Power consumption Max. 19 W
Environment Temperature range 0–40 °C, humidity 0–95 %; non-condensing
Housing Robust metal housing, 1 HU with mounting brackets for 19“ installation,
345 x 44 x 253 mm (W x H x D)
Number of fans None; fanless design, no rotating parts, high MTBF
Interfaces
VDSL 1 / VDSL 2
A VDSL2 as per ITU G.993.2; proles 8a, 8b, 8c, 8d, 12a, 12b, 17a
A Compatible to VDSL2 from Deutsche Telekom AG
A VDSL2 vectoring as per ITU G.993.5
A ADSL conformity according to:
ADSL2+ over ISDN as per ITU G.992.5 Annex B /J with DPBO (over POTS: Annex A/Annex M),
ADSL2 over ISDN as per ITU G.992.3 Annex B (over POTS: Annex A/L),
ADSL over ISDN as per ITU G.992.1 Annex B (over POTS: Annex A)
A Supports just one virtual connection at a time in ATM (VPI-VCI pair) per modem
WAN 1 / WAN 2 WAN 1 SFP: Compatible with optional LANCOM SFP modules. Set as a WAN port ex-factory, can be
congured as a LAN port.
WAN 1 / WAN 2 TP: 10 / 100 / 1000 Base-TX, autosensing full duplex (WAN 1) / autosensing (WAN
2), auto node hub
ETH1 - ETH 4 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in
the LCOS conguration.
Analog 1 - Analog 4 Use the cables of your analog devices to connect them with the analog interfaces. If necessary, use
the enclosed adapters.
ISDN 1 / ISDN 2 ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to the
settings, connect the light-blue ISDN cable either to the NTBA or the ISDN terminal device.
ISDN 2: Internal (NT) ISDN bus. Use the light-blue ISDN cable to connect the ISDN device to the ISDN
interface.
Cong (Com) / V.24 Serial conguration interface / COM-port: 9,600 - 115,200 baud
USB USB 2.0 hi-speed host port for connecting USB printers (USB print server), serial devices (COM-port
server) or USB drives (FAT le system)
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without DHCP), RIP-
1, RIP-2, VLAN, GRE, EoGRE, L2TPv2 (LAC or LNS), IPv6 over PPP (IPv6 and
IPv4/IPv6 dual stack session), IP(v6)oE (autoconguration, DHCPv6 or static)
ISDN DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD
Declaration of Conformity
Hereby, LANCOM Systems declares that this device is in compliance with Directives 2014/30/EU and 2014/35/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE/EN), Installation Guide (DE/EN)
Cables for over ISDN: 2 DSL cables for an IP-based line, 4.25 m; 1 ISDN cable, 3 m (light-blue connectors);
for over POTS: 2 DSL cables, 3 m (dark-blue connectors);
1 Ethernet cable, 3 m (kiwi colored connectors); 1 IEC power cord 230 V (not for WW devices)
Adapters 4 TAE adapters (RJ11 - TAE)
Mounting brackets Two 19” brackets for rack mounting
a
VDSL / ADSL interfaces*
If required, use the supplied DSL cables for the IP-based line to con-
nect each VDSL / ADSL interface to a separate provider’s telephone
socket. For more information, please contact your Internet service
provider.
*For operation with over POTS devices please use the enclosed DSL
cables with the dark blue plugs.
b
WAN 1 interfaces (SFP / TP combo port)
Insert a suitable SFP module (e.g. 1000Base-SX or 1000Base-LX)
into the SFP port. Choose a cable compatible with the SFP module
and connect it as described in the module’s documentation. SFP
modulel and cable are not included.
If desired, alternatively connect the WAN 1 TP interface to a WAN
modem using an ethernet cable.
c
WAN 2 interface (TP)
Connect the WAN 2 interface to a WAN modem using an Ethernet
cable.
d
Ethernet interface
Use the cable with the kiwi-colored connectors to connect one of
the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
e
Analog interfaces
Connect analog terminal devices to the analog interfaces either
directly via RJ11 or with the help of the enclosed TAE adapters.
f
ISDN interfaces
ISDN 1: Internal (NT) or external (TE) ISDN bus.
This feature is controlled by LCOS.
ISDN 2: Internal (NT) ISDN-bus.
A 100-Ohm resistor for line termination is
switchable in LCOS.
g
Conguration interface
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
h
USB interface
You can use the USB interface to connect a USB printer or a
USB storage device.
i
j
Power connector and grounding point (device back side)
Supply power to the device via the power connector. Please
use the IEC power cable supplied (separately available for WW
devices).
ATTENTION: High touch current possible! Connect to earth
before connecting the power supply.
Warning! High touch current.
Connect to earth before
connecting the power supply.
g
h
b
c
a
d
e
f
I
J
LANCOM 1906VA
Quick Reference Guide
Cloud-ready

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Lancom 1906VA bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Lancom 1906VA in de taal/talen: Engels als bijlage per email.

De handleiding is 0,44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Lancom 1906VA

Lancom 1906VA Installatiehandleiding - Deutsch - 18 pagina's

Lancom 1906VA Snelstart handleiding - Deutsch - 1 pagina's

Lancom 1906VA Installatiehandleiding - English - 18 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info