Power adapterExternal power supply adapter (230 V); NEST 12 V / 2 A DC/S; barrel / bayonet (EU),
LANCOM item no. 111303 (not for WW devices)
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
iVPN
OffVPN connection inactive
Green, permanentlyVPN connection active
Green, ashingVPN connecting
eISDN
OffInterface deactivated
Green, permanentlyD-channel active
Green, ickeringISDN data transfer
Red, ickeringISDN transfer error
Red / orange, blinkingISDN hardware error
bOnline
OffWAN connection inactive
Green, permanentlyWAN connection active
Red, permanentlyWAN connection error
cDSL
OffInterface deactivated
Green, permanentlyDSL connection active
Green, ickeringDSL data transfer
Red, ickeringDSL transfer error
Red / orange, blinkingDSL hardware error
Orange, blinkingDSL training
Orange, permanentlyDSL sync
Green, blinkingDSL connecting
dAnalog
OffInterface deactivated
Green, permanentlyInterface activated
Orange, blinkingIncoming call
Green, blinkingConnection active
hVoIP
OffNo SIP accounts dened or VCM is off
Green, permanentlyAll dened and active SIP accounts
(outgoing) were successfully registered
Red, permanentlyNot all dened and active SIP accounts
were registered (possibly still in process)
Red or green,
inverse ashing
Number of currently used lines (connecting
or connected)
fETH
OffNo networking device attached
Green, permanentlyConnection to network device operational,
no data trafc
Green, ickeringData transmission
jReset
Reset buttonOperated e.g. with a paper clip
ashort press: Restart the device
along press: Reset the device
aPower
OffDevice switched off
Green, permanently*Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Red / green blinkingConguration password not set. Without a
conguration password, the conguration
data in the device is unprotected.
Red blinkingCharge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
Please observe the following when setting up the device
ADo not rest any objects on top of the device
A For devices to be operated on the desktop, please attach the
adhesive rubber footpads
AIn case of wall mounting, use the drilling template as supplied
AKeep the ventilation slots on the side of the device clear
of obstruction
ARack installation with the optional LANCOM Rack Mount
(separately available)
LANCOM 1681V
Power
VDSL
Online
ETH 1
ETH 2
VPN
ETH 3
ETH 4
ISDN Status
a
LTE / 4G antennas
Connect the two supplied cellular antennas to the connectors
Ant 1 and Ant 2.
b
VDSL / ADSL interface
Use the supplied DSL cable for the IP-based line to connect the
VDSL interface and the provider’s telephone socket. For more
infor mation, please contact your Internet service provider.
c
Ethernet interfaces
Use the cable with the kiwi-colored connectors to connect one of
the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
d
Analog interfaces
Connect analog terminal devices to the analog interfaces either
directly via RJ11, or with the help of the enclosed TAE adapters,
either directly or via the additionally enclosed RJ11 twin adapters.
e
Conguration interface
Use a serial conguration cable to connect the serial interface
(COM) to the serial interface of the device you want to use for
conguring / monitoring (separately available).
f
ISDN interfaces
ISDN 1:
Internal (NT) or external (TE) ISDN bus.
This feature is controlled by LCOS.
ISDN 2:
Internal (NT) ISDN bus.
A 100-Ohm resistor for line termination is
switchable in LCOS.
g
Power
After connecting the cable to the device, turn the bayonet
connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
h
SIM card slot (bottom side of the device)
Release the SIM-card holder and lever it upwards. Slide the SIM
card into the guide slot of the SIM-card holder. Press the holder
down until it clicks into place.
SIM
LANCOM 1793VA-4G
Quick Reference Guide
Cloud-ready
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.
acebfdhgi
LANCOM 1793VA-4G
j
g4G
OffCellular interface disabled
Green, permanentlyConnection to cellular network active
Green, ickeringCellular data transfer
Orange, permanentlyLogon to cellular network successful
Orange, blinkingLogging on to cellular network
Red, permanentlyHardware error/module unavailable
Red / green, blinkingSIM card error (PIN)
Red / orange, blinkingUploading module rmware
4
abcdef
V
D
S
L / ADSL
D
C
12
V
E
T
H
4
E
T
H
3
E
T
H
2
E
T
H
1
C
o
n
f
i
g
(
C
o
m
)
I
S
D
N
2
I
S
D
N
1
Analog
2/4
Analog
1/3
Gigabit Ethernet 10
/100
/1000
TE / NT
NT
ag
h
SIM
Hulp nodig? Stel uw vraag in het forum
Misbruik melden
Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.
Product:
Spelregels forum
Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:
lees eerst de handleiding door;
controleer of uw vraag al eerder door iemand anders is gesteld;
probeer uw vraag zo duidelijk mogelijk te stellen;
heeft u een probleem en al geprobeerd om dit op te lossen, vermeld dit erbij aub;
heeft u een oplossing gekregen van een bezoeker dan horen wij dat graag in dit forum;
wilt u een reactie geven op een vraag of antwoord, gebruik dan niet dit formulier maar klik op de knop 'reageer op deze vraag';
uw vraag wordt direct op de website gezet; vermijd daarom persoonlijke gegevens in te vullen;
Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.
Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.
Abonneren
Abonneer u voor het ontvangen van emails voor uw Lancom 1793VA-4G bij:
nieuwe vragen en antwoorden
nieuwe handleidingen
U ontvangt een email met instructies om u voor één of beide opties in te schrijven.
Ontvang uw handleiding per email
Vul uw emailadres in en ontvang de handleiding van Lancom 1793VA-4G in de taal/talen: Engels als bijlage per email.
De handleiding is 0,75 mb groot.
U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.
Uw handleiding is per email verstuurd. Controleer uw email
Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.
Er is een email naar u verstuurd om uw inschrijving definitief te maken.
Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken
U heeft geen emailadres opgegeven
Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.
Uw vraag is op deze pagina toegevoegd
Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.