Guidance and manufacturer's declaration-electromagnetic emission
The TH2002 is intended for use in the electromagnetic environment specified below.
The customer or the user of the TH2002 should assure that it is used in such an environment.
Emissions test
RF emissions
RF emissions
CISPR 11
Harmonic
emissions
IEC 61000-3-2
Voltage
fluctuations/
flicker emissions
IEC 61000-3-3
CISPR 11
Class B
Not
applicable
Not
applicable
Group 1 The TH2002 uses RF energy only
for its internal function. Therefore, its RF
emissions are very low
and are not likely to cause any interference
in nearby electronic equipment.
The TH2002 is suitable for use in all
establishments, including domestic
establishments and those directly
connected to the public low-voltage power
supply network that supplies buildings used
for domestic
purposes.
Compliance Electromagnetic environment guidance
Immunity test
Electrostatic
discharge (ESD)
IEC 61000-4-2
Power frequency
(50/60 Hz)
magnetic field IEC
61000-4-8
Guidance and manufacturer's declaration-electromagnetic immunity
The TH2002 is intended for use in the electromagnetic environment specified below.
The customer or the user of the TH2002 should assure that it is used in such an environment.
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and
land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an
electromagnetic site survey should be considered. If the measured field strength in the location in which
the TH2002 is used exceeds the applicable RF compliance level above, the TH2002 should be observed to
verify normal operation. If abnormal performance is observed, additional measures may be necessary, such
as reorienting or relocating the TH2002.
b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
± 6 kV
contact
± 8 kV air
± 6 kV
contact
± 8 kV air
3 A/m 3 A/m
Floors should be wood, concrete or ceramic
tile. If floors are covered with synthetic
material, the relative humidity should be at
least 30 %.
Power frequency magnetic fields should be
at levels characteristic of a typical location
in a typical.
IEC 60601
test level
Compliance
level
Electromagnetic environment guidance Immunity test
Radiated
RF IEC
61000-4-3
Guidance and manufacturer's declaration-electromagnetic immunity
Recommended separation distances between portable and mobile RF
communications equipment and the TH2002
The TH2002 is intended for use in the electromagnetic environment specified below.
The customer or the user of the TH2002 should assure that it is used in such an environment.
The TH2002 Monitor is intended fo use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the TH2002 can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters)
and the TH2002 as recommended below, according to the maximum output power of the communications
equipment.
For transmitters rated at a maximum output power not listed above, the recommended separation distance d
in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is
the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
3 V/m
80 MHz to 2,5
GHz
3 V/m
Portable and mobile RF communications
equipment should be used no closer to
any part of the TH2002, including cables,
than the recommended separation distance
calculated from the equation applicable to
the frequency of the transmitter.
Recommended separation distance
where P is the maximum output power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters,
as determined by an electromagnetic
site survey-a, should be less than the
compliance level in each frequency range-b.
Interference may occur in the vicinity of
equipment marked with the following
symbol:
IEC 60601
test level
Rated maximum
output power of
transmitter
W
Compliance
level
Electromagnetic environment guidance
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHZ 80 MHz to 800 MHZ 800 MHz to 2.5 GHz
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
100 12 12 23
10 38 38 7.3
26

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Laica TH2002 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Laica TH2002 in de taal/talen: Duits, Engels, Frans, Italiaans, Portugees, Spaans als bijlage per email.

De handleiding is 0,76 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info