Auto clean(Optional)
1. Whenever you press the Auto Clean button, Auto Clean Function will be reserved and cancelled.
2. Auto Clean function works before and after cooling or dehumidification mode. For details, refer
to the below points.
3. When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and
indoor Fan is started after 20 seconds.
4. When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean
function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more
Cooling or Dehumidification operation. For Cooling only model, it lasts for 30 minutes for Heat
pump model, for 16 minutes.
5. If you press the auto clean button again during the product operation , Auto Clean function will
be cancelled.
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Forced operation
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Heat pump Model
Cooling Model
Room Temp. ≥ 24°C21°C ≤ Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C22°C23°C24°C
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value when the
fan speed is set to high, and the capacity will be lower at low or medium
fan speed.
High fan speed is recommended when you wish to cool the room quickly.
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for
about 3 seconds.
If you want to stop the operation, re-press the button.