11. AQUARIO insert
Construction diagram of a replace insert with the water system. Drawing 3.
The main part of the replace insert with a water system is the steel water jacket (16) located above
the combustion chamber (1). The steel door (2) equipped with a uniform heatproof glass (3) and a
closing lock with a handle (4) constitutes the front wall of the combustion chamber (1).
The door is mounted in the frame (5). The combustion chamber (1) is inlaid with Acumotte forms
(27). The double-jacket oor whose construction also constitutes the air supply chamber (6) serves
as the base of the system. Air supply is performed by means of the outdoor air supply stub pipe with
the The lower vermiculite deector (26) is located above the combustion chamber. The upper steel
deector (25) is located above it. The vertical water heater re tubes (17) are welded onto the upper
inside walls of the water heater (18). The steel deector (25) and the vertical water heater re tubes
constitute the natural convection channel for fume ow, intensifying heat exchange. During the
burning process inside the insert, fumes wash the combustion chamber (1) walls, then pass under the
lower and upper deectors and ow through the vertical re tubes (17) and then sweep the water
heater (18), intensively transmitting heat to the water. Next, they ow to the ue (10) and through the
smoke channel leading to the chimney.
An adjustable damper (11) is installed in the ue. The position of the damper is adjusted by means
of the damper mechanism (12). Pulling the damper mechanism out by means of the damper handle
(13) is equivalent to opening the fume outlet cover (11). The lower damper (14) is an integral part of
the insert. It is located directly above the combustion chamber (1) and it constitutes an extension
of the upper steel deector (25) along its entire length. Opening it in the preliminary phase of the
burning process makes the path of the fumes to the chimney short, which automatically generates
better draught. Closing it by means of the lower damper handle (15) means directing the fumes
between the two deectors – the lower (26) and the upper (25) one (smoke shelf), which makes the
fume path longer. Drawing 7.; thanks to which the burning of fuel particles which have not been bur-
ned earlier in the combustion chamber (1) takes place in the space between the deectors and above
the steel deector. Additional heat gained in that way is transmitted to the vertical water heater re
tubes (17) and to the water jacket (system) (16). Damper (13) handles (15) are equipped with gradual
damper position adjustment.
The water jacket (system) (16) is equipped with xed stub pipes which are used to connect it to the
heated water central heating system, thermal sensors and the excessive heat transmission system
– the heating coil (24). The stub pipes (20) and (19) with 1 inch female thread (G1’’) are intended for
connecting the insert to the central heating system (the right and the left side of the insert – cross
connection for supply/return recommended). The stub pipes (19) with 1 inch female thread (G1’’) t-
ted in the lower part of the water jacket (system) (16) are intended for connecting water return from
the central heating installation. The stub pipes (20) tted in the upper part of the jacket are intended
for connecting heated water outlet to the central heating installation (the right and the left side of
the insert – cross connection for supply/return recommended).
Stub pipes with male thread (G1/2’’) (23) constitute the heating coil (24) ends. The stub pipe of the
thermal valve sensor (22) with female thread (G1/2’’) is intended for connecting the capillary tube of
the safety valve thermal sensor which controls water ow activation through the heating coil (24).
The heating coil (24) is an element that protects the water jacket against overheating. If heat trans-
mission through the central heating installation is lower than the capacity generated by the insert,
the water temperature in the water jacket may rise to a dangerous level. In such a case, when the
temperature of 95ºC +/- 2 ºC is exceeded, the thermal valve opens water ow through the heating
coil, which cools the water in the water jacket (system). The element (21) is the mounting socket of
the replace controller thermal valve, which controls the operation of the system (central heating
pumps) and of the optional air throttling valve. Such a throttling valve is mounted in the air supply
channel from outside of the building and controls the amount of air drawn through the replace; it
provides optimization of the burning process.
24

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kratki ZUZIA 19 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kratki ZUZIA 19 in de taal/talen: Duits, Engels, Frans, Pools als bijlage per email.

De handleiding is 4,63 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info