High-pressure cleaner
quadro 599 TST
quadro 799 TST
quadro 899 TST
Operating manual
EN
2 3
High-pressure cleaner
quadro 599 TST
quadro 799 TST
quadro 899 TST
EN
Operating manual
Operating manual!
This manual is a translation of the original manual.
Read and conform safety
instructions before use! Technical data will be found in the Spare parts list.
Please be aware that the spare part list is part of the operating manual.
Keep both leaflets for later use or any subsequent owners.
4 5
Contents
Dear customer:
We would like to congratulate you on the purchase of your new high pressure
cleaner and thank you for your confidence in our products!
Your choice has fallen on an absolute quality product!
Kränzle high pressure cleaners are characterized by their convenient and compact
design as well as their high suitability for everyday use.
Highest precision and dimensional accuracy in addition to a technology package
consisting of a multitude of details mark the difference when it comes to
performance, safety and durability.
In order to facilitate handling of the high pressure cleaner, the following pages are
intended to further explain its use. The illustrations may be subject to deviation
depending on the type of equipment or accessory of high pressure cleaner
purchased by you.
Contents ...........................................................................................
Explanatory symbols .................................................................
Safety notes ...................................................................................
Description of high pressure cleaner .................................. 10
General rules .................................................................................. 1
Functional details ........................................................................ 1
Putting into operation .............................................................. 1
Direct suction ................................................................................ 
Applying additives ...................................................................... 24
Taking out of operation ............................................................ 
Small repairs - do it yourself ................................................... 
Kränzle accessories ..................................................................... 30
EU Declaration of Conformity ................................................ 
Warranty ......................................................................................... 33
Inspection reports ....................................................................... 34
Explanatory symbols
Explanatory symbols used in the operating manual
Failure to observe this note may entail
environmental damage.
Note on the use of the high-pressure cleaner that failure to
adhere to the instructions may cause excessive wear or total
breakdown of the medium quadro series.
Warning!
Failure to observe this note may result in serious injuries!
Explanatory symbols affixed to the high-pressure cleaner
In case of improper use, the high pressure jets can be
very dangerous. Do not direct high pressure jet at persons,
animals or active electrical equipment or the high-pressure
cleaner itself.
The high-pressure cleaner may not be connected directly
to the public drinking water supply network.
Risk of burns due to hot surfaces!
Products marked with this symbol may contain constituents
posing a risk to health or the environment if incorrectly dis-
posed of. These products must never be disposed of as
household waste.
Explanatory symbols affixed on the packaging
This symbol denotes recyclable packaging materials
which must not be disposed of as household waste.
Information on proper disposal will be gathered from
the recycling directives issued by your local authority.
6 7
Safety notes - This is prohibited!Safety notes
Replacement of the power supply cables is only permitted by use of an original
power supply cable of the manufacturer and must be performed by a qualified
electrician.
Safety devices serve to protect the user and must never be de-activated or their
function bypassed.
The high-pressure cleaner is to be properly used. The user is required to adhere
to local requirements and to watch out for the persons in the danger zone!
If used in elevated positions where there is a risk of the unit falling to the ground,
it must be secured against rolling away or tipping over.
The high-pressure cleaner is not designed for use by persons with restricted physical,
sensory or mental abilities (including children)!
User operating the high-pressure cleaner should wear the necessary protective
clothing, i.e. waterproof clothing, rubber boots, safety goggles, ear protection
headwear etc. It is prohibited to use the high-pressure cleaner in close vicinity
to people lacking suitable protective clothing.
Use of high-pressure cleaners may result in aerosols being generated. An aerosol
is a mixture of floating solid or liquid particles in a gas. Inhaling aerosol parti-
cles may cause damage to health. Employers are under obligation to carry out
a hazards assessment in order to determine the necessary protective measures
to prevent inhalation of aerosols as governed by the surface due to be cleaned
in each case. Respiratory masks, Class FFP 2 or higher, are suitable for protection
against aqueous aerosols.
Whenever the high-pressure cleaner is left unattended, the mains disconnect
switch must always be switched off.
Do not spray against matter containing asbestos or other hazardous substances!
Never spray flammable liquids or liquids containing solvents such as paint thinners,
petrol, oil or similar liquids! Explosion hazard due to spraying such materials!
Due to the high pressure jet, damage may occur on the objects to be cleaned,
e.g. car tires; therefore, a minimum distance of 30 cm is to be kept!
Prior to putting the high-pressure cleaners into operation, check its components
(High pressure hose, power supply cables, safety trigger gun) for any damage.
Replace defect or damaged components!
Only use high-pressure hoses, couplings and fittings recommended by Kränzle.
Only these accessories ensure safety of the equipment.
If use is made of an extension cable, this must be suitable for outdoor use. In
addition care needs to be taken to ensure that the cable is kept dry and that it is
situated above the ground. We recommend the use of a cable drum capable of
keeping the socket at least 60 mm above the ground.
Never allow children or untrained persons to
use the high pressure cleaner or to play with it!
Children must be kept under supervision to
prevent them from playing with the equipment.
When using high pressure water for cleaning,
make sure that there is a clearly noticeable recoil
effect on the lance. Therefore ensure a firm
footing (see technical data).
8 9
Safety notes - This is prohibited! Safety notes - This is prohibited!
Never direct the high pressure jet at power sockets
or any other electrical installations! Within the
working area, all live parts are to be protected
from both water jet and spray mist.
Apply the safety catch on the safety trigger gun
after each use in order to prevent
unintentional spraying!
Only use a power supply cable in perfect working
order! Do not damage or improperly repair the
power cable (tearing, squeezing, running over, ...).
Never pull the high pressure hose if it has formed
kinks or “nooses”! Never pull the high pressure
hose over sharp edges!
Never direct the high pressure jet at people or
animals! Never direct the high pressure jet at
yourself or other persons, not even to clean
clothing or shoes.
Never direct the high pressure jet at the high
pressure cleaner itself! The high pressure cleaner
may not be placed within reach of the high
pressure jet spray mist!
Always pay attention to the underbody lance
resting on the surface! Bear in mind when using
a curved or angled spraying lance that there is
a significant amount of torque in the recoil!
(The underbody lance is available as
optional accessory).
10 11
Design:
The quadro 599 TST, quadro 799 TST, quadro 899 TST cleaner is a mobile high
pressure cleaner with an advanced arrangement system. Please see construction
scheme for more details.
1. Ergonomically shaped handle
2. Pump head made of special brass
3. Hose drum with 20 m steel fabric
high pressure hose.
For quadro 899 TST with 15 m
steel fabric high pressure hose.
4. Cleaning agent injection hose
5. Detergent valve
. Start/Stop switch
7. Holder for lance
8. Holders for safety trigger gun
with lance
9. Safety trigger gun
10. Large stainless steel
pressure gauge
11. On/Off switch with motor
protection and control light
12. Integrated trolley takes steps
and rough ground in its stride
13. Cable reel for the power
supply cable
14. Infinitely variable pressure
and quantity regulation
15. Cover for water tank
1. Kränzle high pressure cleaner
quadro 599 TST
quadro 799 TST
quadro 899 TST
2. Safety trigger gun with screwing
3. Dirtkiller lance with stainless
steel pipe
4. Stainless steel lance with
flat jet nozzle
5. Operating manual
Spare parts list
Description of high pressure cleaner
This is what you have purchased:
Description of high pressure cleaner
1
1
1
12
11
1
12 13
General rules
Intended use
This high pressure cleaner is to be used solely for high pressure water jet cleaning
applications without detergents or low-pressure cleaning work with detergents
(e.g. with a foam injector or washing brush).
Environmental, refuse disposal and water protection regulations
must be observed!
Inspections
The high pressure cleaner must be inspected according to the “Guidelines
for Liquid Spray Devices” at least once every 12 months by a qualified person,
to ensure that continued safe operation is guaranteed. The results of the
inspection are to be recorded in writing (see Inspection reports).
High pressure cleaners used for commercial purposes have
to be checked by a qualified person at least every 12 months!
Accident prevention
The high pressure cleaner is designed for accidents to be impossible if used
correctly. The user is to be notified of the risk of injury from hot machine parts
and the high pressure jet. The “Guidelines for Liquid Spray Devices” must be
complied with.
Oil leakage
If oil leaks contact your nearest after-sales service (dealer) at once.
(environmental damage, damage to the transmission).
In case of increased humidity or fluctuations in temperature
development of condensed water is possible. If the oil turns
grey or white, you must change it.
General rules
Oil change
The first oil change should be carried out
after approximately 50 operating hours,
then every year or after 250 operating
hours. If the oil turns grey or white, you
must change the oil. In case of exchanging
oil being required, the oil drain screw must
be opened above a container and the high
pressure cleaner be emptied. The oil is to
be caught in the reservoir and disposed
of in an approved manner.
New oil: 0.8 l
Kränzle Gear Oil (Item no.:
400932)
or 10/W60 SAE Semisynthetic oil.
14 15
Insufficient quantity of electricity
Functional details
If there are too many collectors in your
proximity connected to the network at the
same time, the available voltage and the
current intensity may decline. Consequently
the motor of the high pressure cleaner does
not start or even blows. The power supply
may also be insufficient if the power supply
cable is too long or too thin. If extension
cables are too long, this may lead to a voltage
drop causing malfunctions or start-up
difficulties.
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty (see technical data).
Electrical connection
The high pressure cleaner is supplied with a 5 meters long power supply cable.
The mains plug must be fitted to a standard grounded socket with a 30 mA
residual current operated device. Connection up to the mains must be carried
out by a properly trained electrician and must comply with the requirements of
IEC60364-1. The socket must be protected with a 16 A fuse on the mains side.
When using an extension cable, this must have an earthed lead which is properly
connected to the socket. The conductors in the extension cable must have a mini-
mum cross section of 1.5 mm². Plug connections must be of a spray-proof design,
and may not be located on a wet floor. For extension cables of more than 10 m in
length, the minimum cross-section must be 2.5 mm²! When using a cable drum,
the power supply cable always must be unwound all the way.
Functional details
Please note: Lack of water
Lack of water occurs more often than you
probably believe. The more powerful a high
pressure cleaner is the greater is the danger
that a lack of water occurs. If there is only
an insufficient amount of water available,
cavitation (water-gas mixture) arises inside
the high pressure pump, which is normally
noticed too late or even not at all. The high
pressure pump will be destroyed. Please
check the available quantity of water by fil-
ling a bucket with liter scale for one minute.
Required minimum quantity of water (see technical data).
If the metered quantity of water is too small, you have to use a
different water connection, guaranteeing the necessary output.
Lack of water leads to an accelerated wear of the joints (no warranty).
Never let the high pressure pump run dry for more than 60 seconds.
Water supply
Please pay attention to the regulations of your waterworks company!
In accordance with DIN EN 61770, the high pressure cleaner may
not be directly connected to the public drinking water supply lines.
A brief connection however is permissible according to DVGW
(German Association for Gas and Water Affairs) if a non-return
valve with tube ventilator (Kränzle item no.: 410164) is built into the
water supply. Once the water has passed through the non-return
valve it is no longer considered as drinking water. Also indirect
connection to the public drinking water supply lines is permissible
by way of free emission in accordance with EN 61 770; e.g. by using
a reservoir with a float valve. Direct connection to a non-drinking
water supply line is permissible.
16 17
Functional details
Pressure control valve/safety valve
The pressure control valve/safety valve protects the high pressure cleaner from
a build up of excess pressure, and is designed not to permit an excess pressure
to be selected for operation. The limit nut on the handle is sealed with a spray
coating. The operating pressure and spray rate can be steplessly adjusted by
turning the handle.
Replacements, repairs, new adjustments and sealing should only
be performed by qualified persons.
Motor protection switch
Motor is protected against overload by means of a motor protection switch.
In case of motor overload or blocking, the motor of the high pressure cleaner
switches off automatically. If motor tends to switch off repeatedly, make sure
to detect appears. Make sure to detect and remedy the cause of the failure.
Replacements and inspection work should only be performed by
qualified persons when the high pressure cleaner is disconnected from
the power supply, i.e. with plug pulled out from the electrical socket.
Total stop system with delayed motor cut-off
After startup and switching on the high pressure cleaner a green light is displayed.
When opening the safety trigger gun the motor is started via a total-stop system.
When closing the safety trigger gun the motor is switched off only after 30 seconds.
The delayed switch-off is necessary because switching on and off motors frequently
on high pressure cleaners of this size may involve heavy load on the power network
and cause increased wear of internal electrical parts.
Water and cleaning system
Water can be connected at mains pressure to the high pressure pump.
A float valve in the water tank regulates the water inlet. Then, the water is sucked
by the high pressure pump from the water tank and supplied to the lance under
pressure. The high pressure jet is formed by the nozzle at the end of the lance.
Bypassing the water tank water can also be sucked directly out of a pressure-less
container (see direct suction).
Environmental, refuse disposal and water protection regulations
must be observed!
Safety jet pipe with safety trigger gun
The high pressure cleaner can only be operated when the trigger of the safety
deactivation trigger gun‘s trigger is actuated. When the trigger is pulled, the
safety trigger gun opens. The liquid is then transported to the nozzle. The spray
pressure increases and quickly reaches the operating pressure. When the trigger is
released, the safety trigger gun closes and any further spraying of liquid from the
safety jet pipe is prevented. The stainless steel pressure gauge must show 0 bar.
The increase in pressure when the safety trigger gun is closed causes the pressu-
re control valve-safety valve to open. The motor is switched off by the pressure
switch. When thesafety trigger gun is opened, the pressure control valve/safety
valve closes, the motor is started and the high pressure pump resumes pressure
spraying from the safety jet pipe with the selected operating pressure.
The safety trigger gun is a safety device. Repairs should only be
performed by qualified persons. Should replacement parts be required,
use only components authorized by the manufacturer.
Functional details
18 19
2. The medium quadro series is a movable
high pressure cleaner with sturdy trolleys
ideally suited for difficult terrain.
For steering the high pressure cleaner
put the foot against the tipping
support and then pull the device
towards you.
1. For moving the high pressure cleaner
to the place of use, please release
locking break.
Safety shutdown
If the high pressure cleaner is accidentally not turned off after use or the safety
trigger gun is not used for 20 minutes, the high pressure cleaner automatically
changes into safety state by deactivation. By operating the main switch once
more, the high pressure cleaner is activated again.
High pressure hose and spray device
The high pressure hose and spray device which are part of medium quadro series
equipment, are made of high quality material and engineered to conform with
the operating conditions of the high pressure cleaner and are duly labeled.
If replacement parts are required, only such parts that are authorized
by the manufacturer may be used. The warranty is automatically void if
spare parts of third-party providers are used! The high pressure hose and
spray device must be connected in a pressure-tight manner
(without leakage).
The high pressure hose may not be driven over, pulled excessively, or
twisted. The high pressure hose may under no circumstances be pulled
over sharp edges. Defective high pressure hoses must not be repaired
(acc. to DIN 20022) but have to be replaced by new hoses approved by
the manufacturer.
Prior to putting the high pressure cleaner into operation make
sure that all safety instructions be observed.
Functional details
It is imperative that safety instructions be observed during
use of the high pressure cleaner.
Neither set up or operate the medium quadro series in rooms where
there is a risk of fire or explosion nor put it into puddles. Do not use
the high pressure cleaner under water. If, none the less, the high pressure
cleaner is operated in a hazardous area, the applicable safety
regulations are to be observed.
Putting into operation
20 21
3. Release fixation of hose drum.
Unwind high pressure hose straight
and without nooses. Completely
unwind hose. The high pressure hose
may leave signs of abrasion on some
floors. Alternatively, please also find
non-marking high pressure hoses
in our range.
4. Tightly screw together high pressure
hose and safety trigger gun.
6. Screw together lance and
safety trigger gun pressure tightly.
5. Lance on to safety trigger gun.
Putting into operation
7. Check water inlet filter for cleanliness
prior to putting the high pressure
cleaner into operation.
Manually unscrew plug-in coupling.
Take out the water inlet filter using
needle nose pliers and thoroughly
rinse it with clear water and clean
it with the other parts. If the sieve is
dirty, water cannot get through and
pressure will not build up.
8. Connect water hose to water inlet (mi-
nimum requirements;
5 m hose length,
cross-section ¾", 10 bar).
The high pres-
sure cleaner may be connec
ted to a water
mains (1-10 bar pre-pressure)
with either
cold or hot water (up to 60 °C). The
medium quadro series provides the
opportunity of sucking in water out
of a container (see direct suction).
Check the water inlet sieve for damage. Do not operate the
high pressure cleaner without or with a damaged filter.
Be careful when using hot water!
When running your high pressure cleaner with hot water of 60 °C raised
temperatures occur. Do not touch the metal parts of the high pressure
cleaner without safety gloves!
9. Each time check oil level at the oil
dipstick prior to putting the high
pressure cleaner into operation.
Oil level must reach until the upper
edge of marking "OK“.
Putting into operation
When using high pressure hose extensions take care that the max.
length of 20 m is not exceeded!
Accessories may only be connected to a Kränzle-approved trigger gun
with safety catch.
22 23
Direct water extraction
Due to the suction capacity of its high pressure pump (up to 2.5 m suction height,
max. hose length 3 m) this high pressure cleaner can suck in water for cleaning
purposes from separate containers or ponds.
In this case the water tank must be bypassed.
1. Unsrew connecting hose between
high pressure pump and water tank.
2. Screw suction hose with suction filter
(Item.-no.: 15033) with connecting
hose using a spreaded steel pipe fitting
(Item.-no.: 46004).
11. Switch on high pressure cleaner with
opened safety trigger gun. Bleeding
of the high pressure cleaner: Pull and
release trigger of safety trigger gun
several times. Start cleaning task.
10. Connect to circuit (see technical data).
12. When using the filth killer lance make
sure that lance points downward when
starting.
13. Adjust operating pressureinfinitely
using the rotary handle. The maximum
pressure is factory-set.
Putting into operation
Do not touch the mains plug or any live parts with wet or moist hands.
Direct suction
3. Put filled suction hose into the water-
filled container and start the cleaning
job. Use clean water only! Never suck
in water containing chlorine! Do not
suction air!
Prior to starting the first suction the high pressure pump and the
suction hose has to be filled with water!
Note
Depending on the water quality it may occur after a prolonged standstill
that the valves get sticky. Consequently the high pressure cleaner cannot
properly suck in water from a container. In this case connect a hose with
pressurized water to the pump inlet. Having started the high pressure
cleaner the pressurized water opens the valves and the machine resumes
sucking in water from the container. Now you can carry on with your
cleaning task as usual.
It is imperative that safety instructions be observed during
use of the high pressure cleaner.
24 25
2. Dosing of detergent is done by turning
the detergent valve.
By closing the detergent valve the
supply of detergent is stopped.
Only open the dosing valve, if the detergent sieve is placed in a liquid!
Sucked air leads to destruction of the pump seals of the high pressure
cleaner (No warranty)!
The additive must reveal a neutral pH value of 7-9. This machine has been
designed for use of cleaning agents supplied or specifically recommended
by the manufacturer. The use of other cleaning agents or chemicals may
impair the safety of the machine. Observe and comply with relevant
regulations, e.g. directives governing protective equipment, waste-water
regulations, etc.
Attention solvents!
Never suck in liquids containing solvents like varnish solvents, petrol,
oil or similar liquids! Seals inside the high pressure cleaner are no
resistant against solvents! The spray mist of solvents is highly
inflammable, explosive and poisonous.
Suction of additives
Due to the water tank fitted to the medium quadro series it is now possible to
directly suck the detergent into the high pressure pump thus reducing output
loss and increasing the efficiency considerably.
1. Switch off the high pressure cleaner
2. Cut off the water supply
3. Open the safety trigger gun catch briefly until the pressure is released
4. Apply safety catch on the trigger gun
5. Remove high pressure hose and safety trigger gun
6. Emptying high pressure pump: Hold high pressure hose and switch
motor on until water jet stops escaping at the outlet.
7. Pull the plug from the socket
8. Clean high pressure hose and wind up without loops, fix hose drum
9. Clean and wind up the power supply cable
10. Clean the water inlet sieve
11. Apply locking brake
12. Store high pressure cleaners in frost-free rooms in winter
Frost protection
For protecting the high pressure cleaner against frost please empty it completely.
Separate high pressure cleaner from water supply and switch it on. By opening
the safety trigger gun the high pressure pump presses water out of the water
tank. However, do not allow the high pressure cleaner to operate without water
for more than one minute. Fill the anti-freeze agent into the water box and turn
on the high-pressure cleaner. Wait with opened gun until the agent spurts out of
the nozzle.
1. Place chemicals filter into container
with additives
Applying additives Taking out of operation
26 27
The stainless steel pressure gauge shows
full pressure, but from the nozzle comes
only little water or no water at all.
(Inside the stainless steel pressure gauge is
no water but a filling with glycerin to damp
the vibration of the pointer.)
Proceeding:
Switch off the high pressure cleaner. Pull
plug from the socket. Operate safety trigger
gun catch several times to decrease the
pressure.
Unscrew safety trigger gun and lance first,
then rinse high pressure hose to remove
possible soiling.
Check water inlet filter for soiling.
If the problem still exists, take wire (paper
clip) and push through nozzle opening. If
this procedure is not successful, the nozzle
has to be replaced.
Problem
No water from nozzle although the high pressure cleaner is running.
The stainless steel pressure gauge shows full pressure.
Cause
Most likely the nozzle is blocked.
Pull plug from socket prior to starting any repair work!
Small repairs - do it yourself Small repairs - do it yourself
The stainless steel pressure gauge shows
low pressure despite fully turned up pres-
sure regulation. The water from the lance
comes in squirts. The high pressure hose
vibrates.
(Inside the stainless steel pressure gauge is
no water but a filling with glycerin to damp
the vibration of the pointer.)
Proceeding:
Unscrew all 6 valves, one after the other
(hexagonal brass screws, 3 in a row,
vertically and horizontally)
Take out valve body and O-ring by means
of needle nose pliers. Check O-ring for
damage. In case of a damage the O-ring
has to be replaced.
Take a wire (paper clip) and clean valves
under running water.
Do not forget the O-ring during reassembly!
Problem
Irregular jet from nozzle.
The stainless steel pressure gauge shows low pressure.
Cause
Most likely the valves are soiled or sticky.
28 29
Having closed the trigger gun with safe-
ty catch, the high pressure cleaner must
shut down and the stainless steel pressure
gauge must show „0“ bar. If not shut down
and the stainless steel pressure gauge con-
tinuously shows full pressure, this could be
due to leakage at the high pressure pump,
at the pressure switch, at the high pressure
hose or at the trigger gun with safety catch.
In case of a leakage there is no guarantee for possible
consequential damages.
Problem
After closing the safety trigger gun the high pressure cleaner
keeps switching on and off.
The stainless steel pressure gauge continuously displays full pressure.
Possible cause No. 1
Leckage.
Proceeding:
Check connections from the high pressure
cleaner to the high pressure hose and from
the high pressure hose to the safety trigger
gun and also the connection between lance
and safety trigger gun for tightness.
Switch off the high pressure cleaner. Short-
ly press the trigger of the safety trigger
gun to decrease the high pressure cleaner.
Unscrew high pressure hose, safety trigger
gun and lance and check the O-rings. If
the O-rings are damaged they have to be
replaced.
Small repairs - do it yourself Small repairs - do it yourself
Proceeding:
Switch off the high pressure cleaner and
pull plug from socket. Stop water supply.
Operate safety trigger gun catch several
times to decrease the pressure.
Unscrew pump outlet.
There is no guarantee if the high pressure pump is damaged by
defective O-rings due to air induction or lack of water (cavitation).
Remove check body and check O-Ring for
soiling or damage. Also check seal seat in-
side pump housing for soiling or damage.
If sealing rings are defective replace
O-rings at once.
Problem
After closing the safety trigger gun the high pressure cleaner
keeps switching on and off.
The stainless steel pressure gauge continuously displays full pressure.
Possible cause No. 2
The non-return valve is defective.
30 31
Double lance
With insulated ISO handle
Low pressure nozzle
D3035 as standard
Floor washer Round Cleaner
(stainless steel)
From stainless steel
Various executions
Nozzle system 055
∅ 300 mm Item no.: 41105
∅ 420 mm Item no.: 41106
∅ 520 mm Item no.: 41107
660 mm Item no.: 121311
1000 mm Item no.: 12131
Kränzle accessories
Underbody lance
Stainless steel pipe
1000 mm extension
Nozzle system 4007
Item no.: 41075
The high pressure cleaner accessories are safety components!
Any warranty will be void if parts not authorised by Kränzle are used.
Suction hose
with suction filter
With return valve
Hose length 3 m
Item no.: 15033
Kränzle accessories
Item no.: 4101
Sludge suction cleaner
From stainless steel
Max. suction height 3 m
Nozzle system D00045
10 m Item no.: 41051
15 m Item no.: 4105
20 m Item no.: 41052
25 m Item no.: 41053
30 m Item no.: 41054
Please indicate the technical data of the high pressure cleaner
(device type) when placing your order.
Suction hose
with suction filter
With return valve
Hose length 3 m
32 33
The warranty obligation of Josef Kränzle GmbH & Co. KG towards the dealer
from whom you have purchased this Kränzle high-pressure cleaner (= product)
applies to material faults only such as material and manufacturing defects.
Defects attributable to long and frequent use of the product, typically arising
due to the age of the high-pressure cleaner and intensity of its use are defined
as normal wear in respect of product components. Purchaser’s rights to assert
claims for such defects are ruled out. Parts subject to wear include in particular
the pressure gauge, nozzle, valves, sleeves, high-pressure hose and spray equipment.
The product is to be operated in conformity with this operating manual.
The operating manual is deemed to be part of the warranty provisions.
Any changes made to the safety devices of the product or instances of
maloperation – such as exceeding the temperature and speed limits,
undervoltage, insufficient water supply and sewage water, or failure to
use the product for the intended purpose – may result in damage occurring
to the product. Such damage is not deemed to constitute any material defect.
Should the use of accessories or spares other than original Kränzle component parts
und original Kränzle replacement parts be the cause of defects on our product,
this may lead to all warranty claims becoming null and void. Only the use of
original Kränzle replacement parts matching the relevant Kränzle high-pressure
cleaner provides adequate assurance for safe and trouble-free operation of the
Kränzle high-pressure cleaner.
With regard to legal warranty claims, the limitation periods of the respective
countries shall apply.
Where warranty claims apply to any other defects, please contact your
local dealer, presenting the accessories together with your purchase receipt,
or the nearest authorised service centre. This can also be found on the
internet under
www.kraenzle.com.
quadro 599 TST
quadro 799 TST
quadro 899 TST
quadro 5 TST: 00 l/h
quadro 799 TST: 70 l/h
quadro  TST: 00 l/h
Fa. Josef Kränzle GmbH & Co. KG
Manfred Bauer
Rudolf-Diesel-Str. 20, 89257 Illertissen
Machinery Directive 2006/42/EC
EMC Directive 2014/30/EU
ROHS Directive 2011/65/EU
Outdoor Directive 2000/14/EC
88 dB (A)
88 dB (A)
Annex V, Outdoor Directive
2000/14/EC
EN 60335–1:2012/A13:2017
EN 60335279:2012
EN 62233: 2008
EN 55014–1: 2006+A1: 2009+A2: 2011
EN 55014–2: 2015
EN 6100032: 2014
EN 610003–3: 2013
WarrantyEU Declaration of Conformity
We here by declare that the design of
the high pressure cleaners:
Nominal flow:
technical specifications available from:
comply with the following guidelines
and their amendments for high
pressure cleaners:
Noise pressure level, typical:
Noise pressure level, guaranteed:
Applied conformity assessment
procedure:
Applied specifications and standards:
Ludwig Kränzle
(Managing director)
Josef Kränzle GmbH & Co. KG
Rudolf-Diesel-Straße 20
89257 Illertissen (Germany)
Illertissen, 2019-04-05
34 35
Inspection reports
Owner: .................................................................................
Address: ...............................................................................
.....................................................................................................
Type: .......................................................................................
Serial no.: .............................................................................
Repair order no.: .............................................................
Inspection result (check)
The high pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment, the defects found have been rectified so that the
Labour Safety can be confirmed.
The high pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment. The Labour Safety cannot be confirmed unless the
defects found are rectified by repair or replacement of the faulty parts.
Scope of inspection o.k. yes no repaired
Type plate (on hand)
Operating manual (on hand)
Protective covering, Protective device
Pressure line (tightness)
Stainless steel pressure gauge (function)
Float valve (tightness)
Spraying device (marking)
High pressure hose / connector (damage, marking)
Safety valve opens at 10 % / 20 % exceeding
power supply cable (damage)
Protective conductor (connected)
On / O switch
Used chemicals
Allowed chemicals
Inspection data determined value set value
High pressure nozzle
Operating pressure ………………bar
Switch o pressure ……………..bar
protective conductor resistance not exceeded / value
Insulation
Leakage current
Safety trigger gun locked
The next retest according to the Guidelines for Liquid Spray Equipment has to be
carried out by: Month
................................................................... Year .......................................................................
Place, Date .......................................................................... Signature ...............................................................................
High pressure cleaners for industrial use have to be checked by an expert every
12 months! Inspection report on annually carried out Labour Safety Inspection (UVV)
according to the Guidelines for Liquid Spray Equipment. (This inspection sheet serves
as proof for the completion of the retest and must be kept carefully!)
Kränzle-test seals: Item no.: UVV200106
Inspection reports
Owner: .................................................................................
Address: ...............................................................................
.....................................................................................................
Type: .......................................................................................
Serial no.: .............................................................................
Repair order no.: .............................................................
Inspection result (check)
The high pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment, the defects found have been rectified so that the
Labour Safety can be confirmed.
The high pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment. The Labour Safety cannot be confirmed unless the
defects found are rectified by repair or replacement of the faulty parts.
Scope of inspection o.k. yes no repaired
Type plate (on hand)
Operating manual (on hand)
Protective covering, Protective device
Pressure line (tightness)
Stainless steel pressure gauge (function)
Float valve (tightness)
Spraying device (marking)
High pressure hose / connector (damage, marking)
Safety valve opens at 10 % / 20 % exceeding
power supply cable (damage)
Protective conductor (connected)
On / O switch
Used chemicals
Allowed chemicals
Inspection data determined value set value
High pressure nozzle
Operating pressure ………………bar
Switch o pressure ……………..bar
protective conductor resistance not exceeded / value
Insulation
Leakage current
Safety trigger gun locked
The next retest according to the Guidelines for Liquid Spray Equipment has to be
carried out by: Month
................................................................... Year .......................................................................
Place, Date .......................................................................... Signature ...............................................................................
High pressure cleaners for industrial use have to be checked by an expert every
12 months! Inspection report on annually carried out Labour Safety Inspection (UVV)
according to the Guidelines for Liquid Spray Equipment. (This inspection sheet serves
as proof for the completion of the retest and must be kept carefully!)
Kränzle-test seals: Item no.: UVV200106
www.kraenzle.com
Josef Kränzle GmbH & Co. KG
Rudolf-Diesel-Straße 20
89257 Illertissen (Germany)
sales
@
kraenzle.com
Made
in
Germany
© Kränzle 13.05.2019 / Ord. no.: 306000 / Subject to technical modifications and errors.
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kranzle Quadro 899TST bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kranzle Quadro 899TST in de taal/talen: Engels als bijlage per email.

De handleiding is 4,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Kranzle Quadro 899TST

Kranzle Quadro 899TST Gebruiksaanwijzing - Nederlands - 48 pagina's

Kranzle Quadro 899TST Gebruiksaanwijzing - Deutsch - 48 pagina's

Kranzle Quadro 899TST Gebruiksaanwijzing - Français - 19 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info