Regulating the minimum flow level must be done with the tap at the
lowest position (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the control
knob and adjust the screws found on the tap as follows:
1. tighten to reduce the height of the flame 1 (-)
2. slacken to increase the height of the flame (+);
3. With the burners on, rotate the buttons from the maximum to
the minimum position to check the stability of the flame.
Once you have finished regulating, close up the seals again using sealing
wax.
Regulating the minimum flow level of the gas taps
12
To replace the injectors in special burner it is necessary to:
1. Remove spreader (C), the screws (B) holding the cover cap (A)
and the cap itself.
2. Unscrew the inner injector (D) with a box spanner 7 and the
outer injectors (E) with a wrench 7.
3. Replace the injectors.
4. Put back the cover cap, screws and spreader.
Note: make sure that:
1. After replacement the spreader (C) is inserted correctly on the
burner.
Injectors replacement in the wok burner
A
C
B
E
D