— 14 —
English
The following messages are displayed on the centre unit when certain problems are occurring in your system. Take
the recommended actions.
The unit is malfunctioning for some reason.
] Press the reset button on the centre unit. If the "E- 99" / "Mecha Error" code does not disappear, consult your nearest service
centre.
E-99
The protective circuit in the unit activates when the temperature inside the MD player exceeds 60°C (140°F), stopping all operation.
] Cool down the unit by opening the windows or turning on the air conditioner. As the temperature falls below 60°C (140°F), the
disc will start playing again.
E-0d
HOLD
The faceplate of this unit has been removed.
] Replace it.
NO PANEL
E-30
Nothing has been recorded on the MD.
] The next MD will automatically be played.
BLANK
No tracks are recorded on the MD, although it has a title.
] The next MD will automatically be played.
NO TRACK
Troubleshooting Guide
Mecha Error
No MD is loaded.
E-01 / EJECT
• The MD is extremely soiled.
• The MD has so many scratches.
E-04