771557
4
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
2
In order to avoid injury, do not remove the fan guard of
the outdoor unit.
Do not operate the air conditioner with a wet hand.
An electric shock may happen.
Do not touch the heat exchanger ns.
These ns are sharp and could result in cutting injuries.
Do not place items which might be damaged by moisture
under the indoor unit.
Condensation may form if the humidity is above 80%, the
drain outlet is blocked or the lter is polluted.
After a long use, check the unit stand and tting for
damage.
If damaged, the unit may fall and result in injury.
To avoid oxygen deciency, ventilate the room su󰀩ciently
if equipment with burner is used together with the air
conditioner.
Arrange the drain hose to ensure smooth drainage.
Incomplete drainage may cause wetting of the building,
furniture etc.
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch, and a machine trouble may happen.
Never expose little children, plants or animals directly to
the air ow.
Adverse inuence to little children, animals and plants may
result.
Do not allow a child to mount on the outdoor unit or
avoid placing any object on it.
Falling or tumbling may result in injury.
Do not operate the air conditioner when using a room
fumigation - type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of
those who are hypersensitive to chemicals.
Do not place appliances which produce open re in
places exposed to the air ow from the unit or under the
indoor unit.
It may cause incomplete combuston or deformation of the unit
due to the heat.
Do not install the air conditioner at any place where
ammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a re
may break out.
When capacity of indoor unit greater than the sum of
100%, capacity of indoor unit will be attenuated.
When capacity of indoor unit greater than or equal to
the sum of 120%, in order to ensure the e󰀨ectiveness of
machine, and then try to open the indoor units at di󰀨erent
time.
The outdoor unit window-shades should be periodic
cleaning in case of being jammed.
This window-shapes is heat dissipation outlet of components,
if being jammed will cause the components shorten their
service life spans because of overheated for a long time.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The sound pressure level is below 56 dB(A).
This appliance is intended to be used by expert or trained
users in shops, in light industry and on farms, or for
commercial use by lay persons.
2. PARTS NAMES
The air conditioner consists of the indoor unit, the outdoor
unit, the connecting pipe and the remote controller.
(see Fig.1)
Operate the switches and push buttons with an insulated
stick (such as a closed ball-point pen) or insulating gloves to
avoid touching of live parts
Force Cooling Control
Fig.2-1
SW1 forced
cooling button
SW2 spot check function button
SW1 forced
cooling button
SW2 spot check function button
Main control
board
(ODU) 8kW
S1 spot check function button and
forced cooling button
Spot check
board
(ODU)
10/12kW
Main control
board
(ODU)
14/16kW
Force Cooling Control
The ODU main control board is provided with a forced cooling
button SW1. The button is pressed once to send a forced cooling
signal (for 8kW models, the button is long pressed for over 5s)
to all IDUs at once, forcing all IDUs to start cooling. The outdoor
compressor runs at a fxed frequency according to the table and
the IDU fan operates at a high speed. Press the button again to
exit the forced cooling operation (for 8kW models, the button is
long pressed for over 5s).
Forced cooling frequency table
Model 8kW single
phase
10/12/14/16kW
single phase
Forced cooling frequency (Hz) 44 44
Display function
The ODU main control board is equipped with the spot check function
button (In the above fgure: S1 for 8kW and SW2 for 10/12/14/16kW).
The digital tubes on the main control board will show the parameters
of the air conditioner in the following order (the button displays one
parameter at a time). For 8kW models, the Compressor Current Value
and System Address display "--".
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kaysun Mini Amazon III - KMF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kaysun Mini Amazon III - KMF in de taal/talen: Engels als bijlage per email.

De handleiding is 1.07 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Kaysun Mini Amazon III - KMF

Kaysun Mini Amazon III - KMF Gebruiksaanwijzing - Deutsch - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info