owner's manual
3
The function of text run circulate as following g(8/10.5/18KW. 4.
OPERATION AND PERFORMANCE
Normal display
Operating mode
(0Standby; 2—Cooling;
3—Heating; 4Forced
cooling
Operating fan speed grade
(0Power off)
The total capacity
requirements of the
interior unit
The capacity requirements
of the revised external unit
T3 piping temperature
T4 environment temperature
T5 discharge temperature
(actual) (if it is over one
hundred, it will be only
display the hundreds
place and the tens place)
The surface temperature of
Display “--
The last fault or protection
code (if there is no fault or
protection code it will be
display “nn”)
Version of the program
Priority mode (Reserved
Model (8KW: 8,10KW: 10,
18KW:18)
The quantities of the operating
interior units
Total quantities of the interior
units
T2 average temperature
Actual voltage AD value
Actual current value
4.1 Protection Equipment
This Protection Equipment will enable the Air Conditioner to stop
when the Air Conditioner is to be directed running compulsively.
When the Protection Equipment is activated, the Operation
Indicator still lights while the Air Conditioner is not running. But the Check
Indicator Lights.
The protection equipment may be activated in following conditions:
Cooling Operation
The air inlet or air outlet of outdoor unit is blocked.
Strong wind is Continuously blowing to the air outlet of the
outdoor unit.
Heating Operation
Too much dust and rubbish adhere to the dust filter in the indoor
unit
The air outlet of indoor unit is choked
NOTE
When the protection equipment starts, please shut down the
the cooling fin PMV opening manual power switch, and restart operation after problem is
solved.
NOTE
12 hours preheating is imperative after turning on the
power switch. Please do not shut down the power when
the unit is supposed to stop running in 24h or shorter
time. (This is to warm the crankcase heat box to avoid
compulsive start of condenser.)
Pay attention not to block the air inlet and outlet.
Blocks may decrease the efficiency of the unit or startup the
protector, which will stop running.
4.2 About power cut
If power is cut during operation, stop all the operation immediately.
Power comes again. The lamp on the display panel of indoor unit
flashes. And then unit will auto-restart.
Mishandling in operation:
If mishandling happens because of lighting or mobile wireless,
please shut off the manual power switch, and turn on again, then
push the ON/OFF button.
3.
OPERATION RANGE
Use the system in the following temperature for safe and effective
operation. The Max operation temperature for the air conditioner.
(Cooling/Heating)
Table 3-1
Temperature
4.3 Heating capacity
The heating operation is a heat-pump process that heat will be
absorbed from outdoor air and released in doors. Once the
outdoor temperature is decreased, heating capacity decreased
cored pindingly.
Other heating equipment is suggested to be used together when
outdoor temperature is too low.
In some extreme cold upland that buy another indoor unit
equipped electrical heater will obtain better performance. (Refer
Mode
Cooling operation
Heating operating
Outdoor
temperature
-15℃~43
-15℃~27
Room
temperature
17 ℃~ 32
≤27
to indoor unit owners manual for details)
NOTE
1. The motor in Indoor Unit will continue running for 20~30 seconds
for to remove residual heat when the Indoor Unit receiving OFF
command during heating operation.
NOTE
1 If air conditioner is used outside the above conditions, it may
cause the unit to function abnormally.
2 The phenomenon is normal that the surface of air
conditioning may condense water when the relative larger
humidity in room, please close the door and window.
Optimum performance will be achieved within these
3 operating temperature range.
4 To start the outdoor unit at least the installation must have a
demand of 20% of the capacity of the outdoor unit.
2. If the air conditioner malfunction occurs because of disturb,
please reconnect the air conditioner to power, then turn on it
again.
4.4 Three-minute protection feature
A protection feature prevents the air conditioner from being
activated for approximately 3 minutes when it restarts
immediately after operation.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kaysun Mini Amazon II - KMF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kaysun Mini Amazon II - KMF in de taal/talen: Engels als bijlage per email.

De handleiding is 1.01 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Kaysun Mini Amazon II - KMF

Kaysun Mini Amazon II - KMF Gebruiksaanwijzing - Deutsch - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info