3. INSTALLATION
3.1 Installation Preparation
WARNING
Keep all the accessories and tools until installation work is
completed.
Leave the unit inside its packaging while moving, until reaching
the installation site. Where unpacking is unavoidable, use a sling
of soft material or protective plates together with a rope when
lifting, to avoid damage or scratches to the unit.
Hold the unit by the hanger brackets when opening the crate and
moving it, and do not lift it holding on to any other part (especially
the duct connecting ange).
NOTE
Be sure to instruct customers how to properly operate the unit
(especially maintenance of air lter, and operation procedure) by
having them carry out operations themselves while looking at the
manual.
3.2 Select The Installation Site
CAUTION
When moving the unit during or after unpacking, make sure to lift
it by holding its hanger brackets. Do not exert any pressure on
other parts, especially duct connecting ange.
Select an installation site where the following conditions are
fullled and meet with your customers approval.
KRE should be installed far away from ofce, recreation or any
other places where silent environment are required. (install that
in special machine room or wash room is recommended)
install in a place which has sufcient strength and stability.
(Beam, ceiling and other locations capable of fully supporting
the weight of the unit.) Insufcient strength is dangerous. It may
also cause vibration and unusual operating noise.
Do not install the unit directly against a ceiling or wall. (If the
unit is in contact with the ceiling or wall, it can cause vibration.)
Where sufcient clearance for maintenance and service can be
ensured.
CAUTION
Install the units, power supply wiring and connecting wires at
least 1 meter away from televisions or radios in order to pre-
vent interference or noise. (Depending on the radio waves, a
distance of 1 meter may not be sufcient enough to eliminate
the electric interference.)
The bellows may not be able to be used in some districts, so
exercise caution. contact your local government ofce or re
department for details.
When discharging exhaust air to a common duct, the Building
Standard Law requires the use of re proof materials, so
attach a 2m copper plate standing duct.
Do not install the unit in the following locations:
Place subjected to high temperature or direct ame. May result in
re or overheating.
Place such as machinery plant and chemical plate where gas,
which contains noxious gas or corrosive components of materials
such as acid, alkali organic solvent and plaint, is generated.
Place where combus tible gas leakage is likely.
Copper piping and brazed joins may corrode, causing refrigerant
to leak or poisoning and fore due to leaked gas.
Place such as bathroom subjected to moisture.
Electric leak or electric shocks and other failure can be caused.
Near machinery emitting electromagnetic waves.
Electromagnetic waves may disturb the operation of the control
system and result in a malfunction of the equipment.
3.3 Preparations Before Installation
Conrm the positional relationship between the unit and suspen-
sion bolts.
Leave space for servicing the unit and include inspection hatch-
es. (Always open a hole on the side of the electric parts box so
that the air lters, heat exchange elements, fans, be easily be
inspected and serviced.)
Make sure the range of the unit’s external static pressure is not
exceeded.
Open the installation hole (Pre-setting ceilings)
Once the installation hole is opened in the ceiling where the unit
is to be installed, pass transmission wiring, and remote controller
wiring to the unit’s wiring holes.
After opening the ceiling hole, make sure ceiling is level if need-
ed. It might be necessary to reinforce the ceiling frame to prevent
shaking.
Please consult architect or woodworker, if necessary.
Install the suspension bolts. (Use M10 to M12 suspension bolts.)
Use a hole-in anchor, sunken insert anchor for existing ceilings,
or other parts to be procures in the eld to reinforce the ceiling to
bearing the weight of the unit.
Install vibration damping feet. (For vibration damping)
Wooden structure
Put rectangular sticks across the beams, and set pendant bolts.
Wooden span
Beam
Ceiling
Pendant bolt(M10 to M12)
Old concrete roughcast
Use embedded bolts and embedded pulling plugs.
Fig. 3-1
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kaysun KRE bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kaysun KRE in de taal/talen: Engels als bijlage per email.

De handleiding is 1.63 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info