771459
10
Verklein
Vergroot
Pagina terug
1/20
Pagina verder
I&O manual
8
Antifrost protection
WIRING
IMPORTANT!
CAUTION See product nameplate wiring.
Check that the voltage and the frequency of the electrical supply
When the unit is out of service, remember to arrange in good
time for the entire water content in the circuit to be drained
down.
IMPORTANT!
Mixing the water with glycol modifies the performance of the
unit.
Pay attention to the safety instructions regarding ethylene
glycol which are printed on the container.
If the unit is not used during the winter period, the water contained in
the system may freeze.
Draining the water circuit needs to be undertaken in good time.
However, if the operation of draining the system is felt to be too
laborious, a suitable quantity of antifreeze may be mixed with the
water instead.
3.2.2 Electrical connections
CAUTION
correspond to 220-240V single phase at 50Hz; that the available
power is sufficient for the running the equipment; and that the
supply cables are of adequate section for the maximum current
which will be required.
Make sure that the electrical supply system complies with
current national safety regulations.
Electrical connections must be made in accordance with the
wiring diagrams supplied with the machine. For connection to the
electrical supply network, use double-insulated flexible cable,
twin pole + earth, section 1.5mm2 type H05RN-F.
Pass the supply cable through the slot beside the air filter. Use
the cable clamp provided on the inner side of the panel to
secure the supply cable and the connecting cables, and strip
only the length of cable needed to go into the connector block.
If the unit is mounted on a metal surface, earth connections
must be made in compliance with local regulations. If the
optional extra electric heating element is fitted, a separate
power supply must be provided. Use double- insulated flexible
cable, twin pole + earth, section 2.5mm2, type H05RN-F.
IMPORTANT!
Electrical connection of the unit must be carried out by
qualified personnel in compliance with the regulations in
effect in the country where the unit is installed. The company
shall not be held liable for damage to persons or property
caused by incorrect electrical connection.
The power cord type designation is H05RN-R or
above/H07RN-F.
This appliance can be children aged from 8 years and above
and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
The appliance shall be installed in accordance with national
wiring regulations.
DANGER!
Always install a general automatic switch in a protected area
near the appliance with an adequate capacity characteristic
delayed curve with sufficient breaking power. There should be
a minimum distance of 3mm between the contacts. Earth
connection is compulsory by law to ensure user safety while
the machine is in use.
3.2.3 Startup instructions
CAUTION
IMPORTANT!
Machine commissioning or the first start up must be carried
out by skilled personnel qualified to work on this type of
product.
DANGER!
Before starting up, make sure that the installation and
electrical connections have been carried out in accordance
with the instructions in this manual. Also make sure that there
are no unauthorized persons in the vicinity of the machine
during these operations.
Pipeline system has been vacuumed before initial start the
equipment
1 Remove the connecting pipe’s side cover panel by cross
screwdriver.
2 Remove the bolts that showed at the figure by slotted screw
driver. Start up the pump to circulate the pipeline water and
vacuum air from the system until there have water flow out
from bolt holes, and then tighten the bolts the system.
3 Shutdown the system that showed at the figure by slotted
screwed and replace the side cover panel.
Table 3-2
AIR FLOW(m3/h) 255~1530
POWER
PHASE
FREQUENCY AND VOLT
1-phase
220-240V~ 50Hz
CIRCUIT BREAKER/FUSE(A) 15/15
Fig.3-10
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kaysun KFC-SE-2T-500D bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kaysun KFC-SE-2T-500D in de taal/talen: Engels als bijlage per email.

De handleiding is 1.88 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info