Unit is marked with the following symbols:
This symbol indicates that electrical and electronic products must
not be mixed with unsorted household waste. Do not attempt to
dismantle the system on your own. All works involved in dismantling
the system, handling the refrigerant, oil and other components must
be carried out by authorized installation personnel, and the works
must be carried out in accordance with the applicable law. The unit
must be disposed of and treated at special treatment facilities for
reuse, and recycling. By making sure that this product is properly
handled and disposed of, you help to minimize the negative impact
on the environment and human health. For more information, please
contact the installation personnel or local organization.
Use the system within the following temperature and humidity ranges
in order to operate it safely and effectively.
5 Operations
5.1 Operating Range
5.2 Operating System
5.2.1 About the system operations
5.2.2 About the cooling, heating, fan only and auto operations
Temperature
Mode
Outdoor
temperature
Indoor
temperature
Indoor room’s
relative humidity
Cooling mode -5°C ~ 48°C 17°C ~ 32°C below 80%
Heating mode -25°C ~ 24°C 15°C ~ 30°C
The temperature should below 55°C during transporing
The safety device will be triggered if the temperature or humidity
exceeds these conditions, and the air conditioner may not run.
Compared to the cooling operation, the heating operation takes a
longer time.
Need to perform the following operations to prevent the heating
capacity from dropping or prevent cold air from coming out of the
system.
Defrost Operation
In the heating operation, as the outdoor temperature decreases, frost
may be formed on the heat exchanger in the outdoor unit, making it
more difcult for the heat exchanger to heat up the air. The heating
capacity decreases, and a defrosting operation needs to be performed
on the system in order for the system to provide sufcient heat to the
indoor unit.
At this point, the indoor unit will show the defrost operation on the
display screen.
The indoor fan motor will automatically stop running so as to prevent
cold air from coming out of the indoor unit when the heating operation
starts. This process will take some time. This is not a malfunction.
Note
The operating program varies with different combinations of outdoor
unit and controller.
To protect this unit, please turn on the main power supply 12 hours
before you start to operate this unit.
If there is a power outage while the unit is running, the unit will
automatically restart its operation when the power supply resumes.
The indoor units in the air conditioner can be controlled separately,
but the indoor units in the same system cannot operate in the
heating and cooling modes at the same time.
When the cooling and heating modes conflict, the mode is
determined based on the setting of the "S5" mode switch of the
outdoor unit.
Automatic
priority mode
Automatic selection of heating or cooling priority is
based on the ambient temperature.
Heating
priority mode
Indoor units in the cooling or fan mode will stop
running, while indoor units in the heating mode will
run as usual.
Cooling
priority mode
When you select the cooling mode as the priority
mode, the heating operations in the indoor unit stops
running, while the cooling mode will operate as usual;
No.63 (VIP
indoor unit) +
voting priority
mode
If the indoor unit 63 has been set and is turned on,
the operating mode of unit 63 will be regarded as the
priority operating mode of the system. If the indoor
unit 63 has not been set or not turned on, the mode
adopted by most indoor units at the same time will be
the priority operating mode of the system.
In response to
heating mode
only
Indoor units with the heating mode will operate
normally, while indoor units in the cooling or fan
mode will display the "E0 conict".
In response to
cooling mode
only
Indoor units in the cooling and fan modes will operate
normally, while indoor units in the heating mode will
display the "E0 conict".
5.2.3 About the heating operation
5.2.4 Operating system
i
When there is a drop in the external temperature, the heating
capacity decreases. If this happens, please use another
heating equipment and unit at the same time. (Make sure
the room is well ventilated if you are using an equipment that
produces re.) Do not place any equipment that may produce a
re where the air outlets of the unit are or below the unit itself.
Once the unit starts, it takes some time for the room
temperature to rise, as the unit uses a hot air circulation system
to heat the room.
If the hot air rises to the ceiling, causing the ground area to
become cold, it is recommended that you use a circulating
device (to circulate the indoor air). Please contact the agent for
details.
1. Press the "switch" button on the controller.
Result: The running light turns on and the system starts to run.
2. Repeatedly press the mode selector on the controller to select the
required operation mode.
Stop
1. Press the "switch" button on the controller again.
Result: The running light is now off, and the system stopped
running.
Information
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kaysun Amazon V - K2F bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kaysun Amazon V - K2F in de taal/talen: Engels als bijlage per email.

De handleiding is 0.49 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Kaysun Amazon V - K2F

Kaysun Amazon V - K2F Gebruiksaanwijzing - Deutsch - 8 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info