3 Push the hose onto the G 1 ½ pump connecting
piece and fasten it with a hose clamp.
4 Push the connection nozzle into the Quick-Connect.
Illustration C
Erecting/immersing the pump:
1 Push the level sensor onto the rail from above.
Illustration D
2
Fold the feet out or in. (SP 17.000 Flat Level Sensor)
Illustration E
Note
The feet do not necessarily need for be folded out bit
folding out the feet provides a higher delivery rate.
Fold-ing the feet in allows flat suction of liquids to a
residual fluid height of 1 mm.
3 Installing/removing the pre-filter. (SP 17.000 Flat
Level Sensor)
Illustration E
Note
It is not necessary to install the pre-filter, but a higher
delivery rate is reached by installing the pre-filter (only
for SP 17.000 Flat Level Sensor). The pumped liquid is
pre-filtered by the pre-filter to protect the pump from
heavy contamination. Particles of up to 5 mm can still be
pumped when using the filter. Removing the pre-filter
al-lows flat suction of liquids to a residual fluid height
of 1 mm. (only for SP 17.000 Flat Level Sensor).
4 Place the pump securely on solid ground in the
pumped liquid or immerse it via a rope attached to
the carrying handle.
Note
The suction area must not be blocked by soiling. If the
ground is muddy, place the pump on a brick or similar.
Make sure that the pump stands level. Do not carry the
pump using the cable or hose.
Operation
DANGER
Danger of death from electric shock.
Danger of death from electric shock if live parts are
touched.
During operation, do not touch the rope attached to the
carrying handle or any objects that are in contact with
the pumped liquid (e.g. pipelines protruding into the
pumped liquid, railings) and do not reach into the
pumped liquid.
Automatic venting device
1. If the fluid level is low, any sucked-in air, or air pres-
ent in the pump, may escape via the automatic vent-
ing device. Fluid can also leak along with air.
If the pump has problems with suction when the fluid
level is low, unplug and plug in the mains plug re-
peatedly to assist the suction process.
Illustration F
Automatic mode
Note
In automatic mode, the level sensor controls the pump-
ing process automatically. The pump switches on when
the level sensor makes contact with the rising pumped
liquid.
The pump switches off when the level sensor loses con-
tact with the falling pumped liquid and an after-running
time of 15 s has expired.
Illustration G
Switching on:
Minimum fluid level required to enable the pump to suck
independently (= minimum switch-on point):
SP 17.000 Flat Level Sensor: 7 mm (57 mm when
using the pre-filter)
SP 22.000 Dirt Level Sensor: 50 mm
Highest adjustable switching height of the level
sensor:
SP 17.000 Flat Level Sensor: 190 mm (240 mm
when using the pre-filter)
SP 22.000 Dirt Level Sensor: 237 mm
Minimum residual fluid height/max. suction depth:
SP 17.000 Flat Level Sensor: 1 mm (without pre-
filter, with folded feet)
SP 22.000 Dirt Level Sensor: 35 mm
Note
It is recommended to use the pre-filter.
Note
Make sure that the pump stands level. Otherwise the
level sensor may not lose contact with the fluid and the
pump can run dry.
1. Push the level sensor to the desired switch-on
height (contact with the pumped liquid).
Note
The higher the level sensor is set, the higher the switch-
on and switch-off points. See the following table for ap-
plication examples:
2. Set the switch to Automatic mode (AUTO).
Illustration H
3. Plug the mains plug into a mains socket.
Manual mode
Note
In manual mode, the pump stays switched on.
1. Set the switch to Manual mode (MAN).
Illustration H
2. Plug the mains plug into a mains socket.
ATTENTION
Risk of damage from dry running!
Dry running leads to increased wear on the pump.
Do not leave the pump unattended in manual operation.
In case of dry running, immediately pull the mains plug
out of the socket.
Application area SP 17.000 Flat
Level Sensor
SP 22.000 Dirt
Level Sensor
Shafts with a di-
ameter < approx.
1 m (e.g. drain-
age)
Level sensor in
uppermost posi-
tion
Level sensor in
uppermost posi-
tion
We recommend-
ed using the pre-
filter
Pre-filter flap
closed (protection
against soiling)
Swimming pools,
ponds (only for
SP 22000 Dirt
Level Sensor)
Level sensor in
lowest position
Level sensor in
lowest position
Starting pumping
with the pre-filter
or folded-out feet
Pre-filter flap
closed (protection
against soiling)
Continuing pump-
ing without the
pre-filter and fold-
ed-in feet (reach-
es a residual fluid
height of 1 mm)
Note
Perform in manu-
al mode. Monitor
the switch-off/
shallow suction.
11

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Karcher-SP-22.000-Dirt-Level-Sensor

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Karcher SP 22.000 Dirt Level Sensor bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Karcher SP 22.000 Dirt Level Sensor in de taal/talen: Alle talen als bijlage per email.

De handleiding is 4.71 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info