Note
The pump can pump up to a residual fluid height of 25
mm (SP 9.500 Dirt and SP 11.000 Dirt) or 1 mm (SP
9.000 Flat).
The specified residual fluid heights are only achieved in
manual operation.
The float switch must be able to move freely.
1. Fold in the feet, see chapter Initial startup (SP 9.000
Flat).
Note
By folding in the feet, flat suction of the fluid up to 1 mm
residual fluid height is possible in manual operation.
2. Fasten the float switch in the lock so it points up-
wards.
Illustration G
ATTENTION
Risk of damage from dry running!
Dry running leads to increased wear on the pump.
Do not leave the pump unattended in manual operation.
In case of dry running, immediately pull the mains plug
out of the socket.
3. Plug the mains plug into a mains socket.
Finishing operation
1. Pull the mains plug out of the socket.
The device stops.
ATTENTION
Risk of damage!
Risk of damage due to dried soiling or additives.
Rinse and clean the device immediately after each use.
2. If dirty liquids or liquids with additives have been
pumped, rinse and clean the device immediately af-
ter finishing operation, see chapter Rinsing and
cleaning.
3. Drain the device and accessories and let them dry.
Care and maintenance
DANGER
Risk of electric shock and risk of injury!
The device contains electrical and mechanical compo-
nents.
Cleaning and user maintenance may not be carried out
by children.
Rinsing and cleaning
ATTENTION
Risk of damage!
Risk of damage due to dried soiling or additives.
Rinse and clean the device immediately after each use.
1 If dirty liquids or liquids with additives have been
pumped, the device must be rinsed afterwards: Use
the device to pump clear fresh water without addi-
tives until all soiling or additives have been flushed
out of the device.
DANGER
Risk of electric shock and risk of injury!
The device contains electrical and mechanical compo-
nents.
Always disconnect the device from the power supply
before assembling, disassembling or cleaning.
2 Pull the mains plug out of the socket.
3 Press the Quick-Connect button and remove the
connection nozzle.
Illustration C
4 Where necessary, remove residue from the hose
and on Quick-Connect.
5 Clean the outside of the device with a soft, clean
cloth and clear fresh water.
6 Drain the device and accessories and let them dry.
Service
The device is maintenance-free.
Transport
Manual transport
CAUTION
Risk of injury from tripping!
There is a risk of injury from tripping on loose cables and
hoses.
Be careful of cables and hoses when moving the device.
1. Lift and carry the device by the carrying handle.
Transport in vehicles
WARNING
Risk of injury, risk of damage!
Note the weight of the device during transport.
Store or secure the device in accordance with applica-
ble guidelines so that it cannot slip or be thrown around
during transport.
2. When transporting the device in vehicles, secure it
to prevent it from slipping or overturning in accord-
ance with the respectively applicable guidelines.
Storage
ATTENTION
Risk of damage due to frost!
An incompletely emptied device can be damaged by
frost.
Completely empty the device and accessories before
storing them.
Protect the device from frost.
Store the device in a frost-free place and not outdoors.
CAUTION
Risk of injury and damage!
The device may tip over on sloping surfaces.
Be aware of the weight of the device during storage.
1. Completely empty the pump and accessories.
2. Allow the pump and accessories to dry out.
3. Store the pump in a frost-protected place.
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
Fault Cause Rectification
Pump is running, but not
delivering
Air is in the pump. 1. Check for correct startup (see chapter
Initial startup and Operation).
Dirt particles block the suction area. 1. Pull the mains plug out of the socket.
2. Clean the suction area.
The fluid level is too low (manual opera-
tion), see chapter Technical data.
1. Immerse the pump deeper into the feed flu-
id, see chapter Manual operation.
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Karcher SP 11.000 Dirt bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Karcher SP 11.000 Dirt in de taal/talen: Alle talen als bijlage per email.

De handleiding is 4.58 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info