With the ON/OFF switch the following three operating
conditions can be switched:
In the automatic mode the house & garden pumps auto-
matically maintain the pressure in the system. If the
pressure falls below approx. 0.13 MPa (1.3 bar), the
pump is started. The pump is running as long as the flow
rate
> is approx. 60 l/h. If the withdrawal of water is complet-
ed, the pump goes into the stand-by mode after a short
stopping time. The system is now under pressure. In
case of water withdrawal and the resulting loss of pres-
sure the pump starts again.
The eco!logic models do not consume ener-
gy in the stand-by mode (input power = 0 W).
1Connection adapter for pumps G1
2 Connection G1 (33.3 mm) suction pipe (inlet)
3 Filling nozzle
4 Pre-filter and integrated check valve
5 Cover
6 2-way connection adapter for pumps G1
7 Connection G1 (33.3 mm) delivery line (output)
8 ON/OFF switch
9 Cable storage and mains cable with plug
10 Cable clip
11 Error display
A Error on suction side
B Error on delivery side
Illustration
Screw the connection adapter in the suction con-
nection of the pump (inlet).
Tighten manually.
Connect the vacuum-proof suction hose.
Note
In order to reduce the time required for suction to start
again, use a suction hose that is equipped with a back-
flow stop. This prevents the emptying of the suction
hose after use (see accessories).
Do not install the backflow stop directly on the pump
(suction or delivery side).
If sandy water is to be delivered, we strongly recom-
mend the use of an additional pre-filter (see optional ac-
cessories). Please install this filter on the suction side of
the pump, between the suction hose and the pump.
Please use original Kärcher suction pipes, filter compo-
nents and hose connections.
When using components of other manufacturers, mal-
functions during drawing in the delivery fluid may arise,
especially when using bayonet connection systems.
Do not use quick couplings, but screwed connections
with domestic or permanent installations.
Illustration
Screw the connection adapter in the delivery con-
nection of the pump (outlet).
Tighten manually.
Connect delivery line.
Illustration
The 2-way adapter allows the simultaneous operation of
two appliances (e.g. washing machine or sprinkler). It
can be mounted in a way that either both outlets are
used at the side or one outlet at the side and one outlet
at the top. If only one outlet is used, the outlet that is not
required can be closed by means of the accompanying
closing cap.
Illustration
Unscrew the lid of the filler neck and fill in water up
to the brim.
Manually screw the lid all the way to the stop on the
filler neck.
Open existing shutoff valves in the pressure pipe.
Note
Even the smallest of leakage leads to malfunctioning.
With a permanent installation the pump can be screwed
onto a suitable surface.
Illustration
Pull out and turn the rubber feet on both sides of the
casing.
Reinsert the rubber feed into the casing.
Use suitable screws to screw it onto a level surface.
In case of a permanent installation the installation of a
flexible component such as a flexible pressure compen-
sating hose (see optional accessories) on the pressure
side is recommended. This has the following benefits:
More flexibility during set-up and installation.
Noise reduction, as no vibrations are transferred to
pipes in the domestic water system.
In case of small leaks, the pump does not switch as
often.
Note
To facilitate subsequent emptying and pressure release
of the system, we recommend the installation of a stop-
cock between pump and pressure line.
(not included in delivery)
By closing the shut-off valve when emptying the pump you
can prevent water from escaping from the pressure line.
Install a pressure equalization container (see special
accessories) in case of increased pressure reductions
due to leakages in the domestic system (pump switches
on regularly without water removal).
Insert the mains plug into the socket.
Switch on the appliance using the ON/OFF switch.
Optimum convenience with operation in the auto-
matic mode.
Illustration
In order to reduce the suction time, lift the delivery
hose approx. 1m.
Wait till the pump sucks in and transports water uni-
formly
Operation
Settings
Switch position I/On
Continuous operation
Switch position 0/Off
Off
Switch position Auto
Automatic mode
System operation
Description of the Appliance
Preparing the Appliance
Permanent installation
Operation
14 EN
14

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Karcher-BP-5

Zoeken resetten

  • Karcher hogedrukspuit lekt behoorlijk veel water. Kan er zelf niets aan doen.
    Lekker duurzaam die water verspilling.
    Gesteld op 9-4-2023 om 16:21

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Karcher BP 5 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Karcher BP 5 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Turks als bijlage per email.

De handleiding is 3,62 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info