Wireless thermostat TP-98 - 2 - MFR51500
Wireless thermostat TP-98
This thermostat can replace a common indoor residential thermostat. It
is designed to be used with electric, gas or oil heating system. The
easy to read display shows the current room temperature and
temperature adjustment is very simple. The main advantage is that
there is no need of a cable between the thermostat and the heating
system.
Installation
The TP-98TX should be mounted
in a dry indoor location. Choose a
mounting location about 1.5 meters
above the floor in the area with
good air circulation. Avoid places
with drafts, dead air spots and
radiant heat from the sun or
appliances. It should not be
installed close to any metal
structure or other objects that may
obstruct radio signal transmissions.
1. Remove the front housing of the thermostat. (using a screwdriver)
2. Insert the batteries. Current temperature will appear on the display if
not check the batteries.
3. Attach the thermostat to the wall with the two screws.
Mounting the receiver unit
Place the receiver unit in a suitable place near the heater. Wiring
of the unit to the heater should be done only by a professional
electrician:
1. Release the upper cover by pressing the plastic log on the top side
of housing.
2. Release the internal cover (1 screw).
3. Mount the unit to the desired location (2 screws).
4. Connect power 230VAC / 50Hz to terminals L and N.
5. Two PE terminals are available for a protective earth connection.
6. Terminals C (common), N.O. (normally open) and N.C. (normally
closed) are outputs of the relay contact. This contact is protected by
a 6.3A fuse. The contacts are galvanic separated.
Note: The
thermostat, which
has a unique code,
is enrolled to the
receiver unit from
the factory.
A built-in LED
indicator indicates a
status of the output
relay.
TEMPERATURE SETTING
In the normal operation mode the thermostat shows the room
temperature. To set a desired temperature:
1. Press or button to view the set temperature. The sign SET
will appear on the display.
2. Hold
or button for approximately 3 seconds till the
temperature indicator will flash once.
3. Use
or button to increase or decrease the temperature
setting. If no button is pressed for 10 seconds the unit will be
switched back to the normal operation mode.
The programmed temperature range is from 5˚C to 35˚C.
The temperature span between switching ON and OFF is 1˚C. For
example, if the temperature setting is 20˚C, the heater will be switched
on when the room temperature drops to 19.5˚C and will be switched off
when the temperature rises to 20.5˚C. When the thermostat is on the
symbol HEAT will be shown on the display.
When the temperature is above 40˚C ‘HI’ will be shown on the LCD
and ‘LO’ will be shown when temperature falls below 0˚C.
When the voltage of the batteries is low the LCD will be turned off. In
that case the batteries should be changed.
Enrolment of the thermostat into the receiver unit
The thermostat has already been enrolled to the receiving unit in
the factory. If you change the thermostat for a new one it must be
enrolled to the receiver unit in the following way:
1. Remove the batteries from the thermostat for 2 minutes.
2. Remove the upper housing from the receiver unit.
3. Keep pressing the button inside the receiver until the 4th LED starts
flashing.
4. Place the batteries into the thermostat. The LEDs in the receiver will
flash once to confirm the enrolment.
Note: Each receiver unit can cooperate only with one thermostat. If any
other device (remote control etc.) has been enrolled to the receiver the
receiver must be reset before enrolment of the thermostat. To reset the
memory make the 4th LED flashing by pressing the button and then
press and hold the button until all LEDs flash rapidly.
Specifications
Thermostat TP-98TX
Power Source: two AAA 1.5V Alkaline batteries
Temperature Measurement: 0 - 40˚C
Temperature Accuracy: ±1.0˚C
Temperature Control: 5 - 35˚C
Temperature Control Span: 0,5˚C
Output On Delay: 20 seconds
Working frequency 433,92 MHz
Working distance up to 100 m (open area)
Coding: digital, each thermostat has a unique
floating code
Operating Temperature: -10˚C to 50˚C (non-condensing)
Storage Temperature: -30˚C to 60˚C
Size: 73.5 X 28.0 X 73.5 mm
Housing: Polycarbonate (PC)
Weight: 90 g (battery not included)
Receiver unit UC-222
Voltage: 230 V AC
Power consumption: max. 1 W
Operating frequency: 433.92 MHz
Coding: digital, each thermostat has
a unique floating code
Output relay: over switching dry contact
Fused 6 A at 250 V
Can be operated according to ERC REC 70-03
Hereby, Jablotron Ltd., declares that this TP-98 is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC.
Note: Dispose of batteries safely depending on the type of the
batteries and local regulation. Although this product does not contain
any harmful materials we suggest you to return the product to the
dealer or directly to the producer after usage.
2
1
3
4
Relé

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron TP-98 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron TP-98 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,11 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info