JA-82K control panel installation manual - 8 - MKH51103
1. First enroll the sub control panel to the desired address in the master
control panel by entering 299 on the sub control panel’s keypad in
Service Mode – see 5.1 for full details.
2. Switch the master control panel to Service Mode.
3. In the sub control panel, enter enrollment mode by keying in “1” in
Service Mode and select the desired address.
4. In the master control panel enter 290. This way the control panel will
enroll to the sub control panel to the desired address as a remote
control.
5. Switch both control panels to maintenance mode and check that all-
section setting of the master control panel also sets the sub control
panel and unsetting the master control panel unsets the sub control
panel too. Expect approximately 2 seconds of delay between control
panels.
Notes for operating the sub control panel:
The sub control panel can still be operated independently via its keyfob
or keypad e.g. it can be set while the master control panel is unset. If
the master control panel changes its status later on, it will then control
the sub control panel to achieve synchronisation.
To disable the master control panel’s ability to control the sub control
panel, enter the sub control panel’s enrollment mode, select the
address where the master control panel is enrolled and erase the
master control panel from this address by pressing and holding key 2.
The status of the sub control panel is not displayed on the master
control panel.
6.10 Master code reset
If the master code has been forgotten or a card lost, it is possible to use
the following sequence to reset the master code to the factory-default 1234:
2 9 1
Note: Resetting the master code has no effect on other codes and cards.
Resets are recorded in the control panel memory and sent to the ARC.
6.11 Enrollment to other devices (UC, AC)
Keying in 299 sends an enrollment signal to enroll the control panel to
UC-82 or AC-82 receiving modules (see 5.5). This sequence can also be
used to enroll a sub control panel to a master control panel (see 6.9).
6.12 Setting (Arming) without an access code
“Hot” setting keys (short-cut keys for setting) A, B, ABC or entering “
number” can be enabled for use without a valid access code or card. If
disabled, then hot key use or entering “ number” has to be followed by a
valid access code or card to have any effect:
Function/sequence 301 300
All-section setting
ABC key Code/card
Setting of A
A key A key, code/card
Setting of AB (or B)
B key B key, code/card
Event memory recall
4 4 code/card
fig. 10 setting / arming with or without code
If you remotely operate the system by mobile phone, you can press 1
for the ABC key, 2 for key A, and 3 for key B.
Controlling the PG outputs by keying in 8 or 9 or pressing ON and
#OFF is unaffected by these settings. These keys can however be
disabled by a special sequence (see 6.26).
Factory default setting: Setting (arming) without an access code enabled.
6.13 Triggered-detector indication
Pressing the ? key checks if any detectors are permanently triggered,
e.g. if any doors or windows are open.
3 1 1 indication enabled
3 1 0 indication disabled
Factory default setting: indication enabled
6.14 Confirmation of intruder alarms
To reduce the risk of false alarms and to comply with British standard BSI
DD243, the control panel allows alarm confirmation logic to be enabled as
follows:
3 2 1 confirmation logic enabled
3 2 0 confirmation logic disabled
Confirmation logic:
If the system is set (armed) and any intruder detector gets triggered,
i.e. a detector with an instant, delayed, or next-delayed reaction, an
alarm will not be caused but the control panel will record a so-called
unconfirmed alarm.
If any other intruder detector is triggered in a set section within 40
minutes of the above event, an intruder alarm will be triggered. If no
other detector is triggered during this period, the control panel will stop
waiting for confirmation.
The alarm must be confirmed by another detector than the first one. If
the same type of detector is used for confirmation thentheir detection
area must not cover the same area.. This must be ensured by the
proper location of detectors.
An unconfirmed alarm is recorded in control panel memory but can
also be sent to the ARC, or to the user by SMS report.
If the first triggered detector has a delayed reaction, it will start a so-
called unconfirmed entrance delay. This delay is indicated the same
way as an ordinary entrance delay., If no other delayed detector is
triggered during this delay, there will be no alarm. If the entrance delay
is exceededthe unconfirmed alarm is recorded in the control panel
memory. If there is any other delayed or next-delayed detector
triggered during the entrance delay period, it will confirm the entrance
delay, and if this delay is exceeded (due to no unsetting being done) it
will trigger an intruder alarm at the end of the delay.
If a delayed detector is triggered within 40 minutes after the triggering
of an unconfirmed alarm or the moment the unconfirmed entrance
delay is exceeded, the confirmed entrance delay starts running and
when it times out (due to no unsetting being done), an intruder alarm is
triggered.
If the unconfirmed entrance delay is confirmed by an instant detector it
will trigger an internal warning (IW) alarm immediately (e.g. an internal
siren) and if the entrance delay times out then an external alarm (EW)
will be triggered.
An unconfirmed alarm can be confirmed by any other intruder detectors
in the system as long as the detectors are assigned to a set (armed)
section.
The confirmation of intruder alarms concerns only detectors with
instant, delayed, or next-delayed reactions. It has no effect on fire,
panic, 24-hour, tamper, or technical alarms. These alarms are triggered
immediately without confirmation.
Note: When the first detector is triggered it begins a process which waits 40
minutes for any possible confirmation of the alarm (unconfirmed alarm status)
during which the system works exactly the same way as if the confirmation
function had not been enabled.
Warning: If intruder alarm confirmation is enabled, it is necessary to install
enough detectors in the building to detect an intruder even if he/she is only
moving in one particular place.
Factory default setting: confirmation disabled
6.15 Exit delay beeps
The exit delay can be indicated by beeps from the keypad and internal
wireless siren. The beeps get faster in the last 5 seconds.
3 3 1 Beeps enabled
3 3 0 Beeps disabled
Factory default setting: Beeps enabled.
6.16 Exit delay beeps while partially setting (arming)
The exit delay caused by partial setting, e.g. using the A or B key, can
also be indicated by keypad beeps and internal-siren beeps. The beeps get
faster in the last 5 seconds. The feature is linked to 331 parameter setting.
3 4 1 Beeps enabled
3 4 0 Beeps disabled
Factory default setting: Beeps disabled.
6.17 Entrance delay beeps
The entrance delay can be indicated by keypad beeps and internal-siren
beeps:
3 5 1 Beeps enabled
3 5 0 Beeps disabled
Factory default setting: Beeps enabled.
6.18 Setting (arming) confirmed by wired-siren chirp
A hard-wired siren connected to the IW terminal of the control panel can
audibly indicate setting by one beep, unsetting by two beeps and unsetting
after an alarm by three beeps. Four beeps mean an invalid attempt at setting
the system has occurred.
3 6 1 Chirps enabled
3 6 0 Chirps disabled
Note: In JA-80L wireless sirens, this function can be individually enabled for
each siren. (see the siren manual).
Factory default setting: Hard-wired siren chirps disabled
6.19 Sirens always sound during audible alarms
Using this sequence it is possible to disable internal and external sirens
(IW and EW) if any part of the system is unset (partial setting), i.e. when
someone is home.
8

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-82K OASIS bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-82K OASIS in de taal/talen: Engels als bijlage per email.

De handleiding is 0,66 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Jablotron JA-82K OASIS

Jablotron JA-82K OASIS Installatiehandleiding - Deutsch - 23 pagina's

Jablotron JA-82K OASIS Gebruiksaanwijzing - English - 23 pagina's

Jablotron JA-82K OASIS Aanvulling / aanpassing - English - 1 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info