The JA-80F wireless keypad MLH51300
1
The JA-81F wireless keypad
The JA-81F is a component of Jablotron’s OASiS alarm system and is designed to
control and program the system. It has a built-in proximity access card reader and
allows the wiring up of a separate door detector. The battery-powered keypad
communicates wirelessly using OASiS protocol.
Installation
Installation shall only be undertaken by technicians holding a certificate
issued by an authorized distributor. The keypad is for indoor installation only,
typically by the main entrance door. Avoid locating it close to metal objects,
which could shield radio communication.
1. Open the keypad housing (by pressing the tab on the bottom) using a
screwdriver. The tab is also accessible from the front after opening the key
cover.
1. Install the rear housing to the desired location
2. Install the external hard-wired detector (if required) route its cable
through the rear housing and connect to the IN and GND terminals.
3. Enroll the keypad to the control panel (see the control panel
installation manual) as follows:
Enter enrollment mode in the control panel (if the system does not
have a keypad already, briefly short the reset link on the control panel
main board, or if a keypad is present, then press key 1 in service
mode).
Install the battery into the keypad to trigger enrollment.
Exit enrollment mode by pressing the # key.
4. Attach the keypad to the rear housing.
5. Instructions on how to use the keypad can be found in the control panel
operating manual.
Keypad menu
The menu can be entered in Service mode by holding the ? key. Then the
internal keypad menu will be displayed. Using the arrows on keys 1 and 7 you
can scroll through the menu:
Display Key Description
Tamper ON
¾
Disable / Enable the tamper sensor
(only for service purposes)
Door chime ON
¾
Disable / Enable sound when IN triggered
Beeper ON
¾
Disable / Enable system sounds
Brightness

Sets the display brightness 0 - 9
Contrast

Sets the display contrast 0 - 9
Edit text
¾
Entry to keypads text editing
English
¾
Sets English (reload default texts)
Čeština
¾
Other languages ...
To exit the menu, press # (exiting also occurs after 10 seconds’ inactivity).
Notes:
The menu can be displayed even if the keypad has not been enrolled to the
control panel.
Each keypad has its own menu, i.e. each keypad in the system can have its
own unique settings.
The keypad keeps its settings even if its power is disconnected (settings can
only be altered via the keypad menu).
The menu can also be entered when the ¾ key is kept pressed while the
keypad is being powered-up.
Keypad sleep mode
When battery-powered, the keypad saves energy by turning itself off when the
cover is closed or automatically after 20 seconds of inactivity (15 minutes in service
mode). The keypad is woken up by: opening the keypad‘s flip cover, pressing any
key, or triggering the wired door detector input - see below.
Optional AC adapter
If the keypad is powered by an AC adapter (model: Jablotron DE01-12 for
terminals: +U and GND), it will not turn off after 20 seconds of inactivity. If the
adapter is used, batteries should still be installed. Only turn on the AC adapter
after the keypad unit has been powered up by batteries and the two halves of
the housing are back together.
Note: To comply with EN standards the keypad does not indicate the status of
the alarm system. If desired, the system setting / unsetting status can be
programmed in the control panel to be permanently indicate by the keypad.
Installing a door detector
It is possible to wire up a detector(s) to the keypad. The IN input terminal is
triggered when disconnected from GND. The control panel’s reaction to the IN input
being triggered is a delayed intruder alarm linked to the keypad‘s address. If
desired, another reaction can be programmed in the control panel. The IN input can
indicate a door being permanently open (status reaction). If the IN input is not used
then it must be shorted to GND.
1 2 3
ABC
4 5 6
A
7 8 9
ON
0 #
B
?
OFF
ESC
ABC
OASiS
IN
GND
+U
Note: The lifetime of the battery is reduced proportionally to how frequently the
door detector is triggered and how often and how long the keypad is battery-
powered.
Testing keypad communication
In service mode, the control panel allows you to measure the keypad’s radio
signal strength. To test the keypad signal, trigger either its IN input or its
tamper sensor.
Note: the control panel measures the strength of the signal transmitted by the
keypad. It is impossible to measure the signal strength received by the keypad
from the control panel. If the keypad has lost communication with the control
panel (e.g. if the control panel is damaged) it would display COMM ERROR a
communication error. If you re-power a control panel, which previously worked
with a keypad, and the keypad does not function, then we recommend
disconnecting and re-connecting the keypad batteries.
Controlling the PgX output
The PgX output can be switched ON and OFF by pressing the ON (¾) and
OFF (#) buttons long (for 5 seconds). The function of PgX must be set in the
control panel. A long beep confirms the change of the output’s state.
Keypad text editing
The most convenient way to edit text is to use a PC running OLink software.
To transfer edited text from a PC to the keypad, the keypad (with its batteries
installed) has to be connected either to the OASiS system‘s digital bus (i.e.
one cable from the keypad to the control panel, and another cable from the
control panel to the PC) or directly from the PC. The texts are transferred by
choosing the Save menu in the Texts window in OLink software.
The names can be edited via the keypad in the “Edit Text” menu item – see
the control panel installation manual. The edited text is only stored in the
keypad unit used for editing.
Battery replacement
The system checks the battery status and if discharged it will inform the user or
the installer. The keypad will continue to work but will also indicate a low
battery as well as the backlight being reduced. Batteries should be replaced
within 2 weeks by a qualified technician in service mode. If they are not, the
keypad is switched off when the battery power falls under a critical limit.
Note: Both batteries must be always changed together and with
identical types (manufacturer).
Removing the keypad from the system
If the keypad is removed from the system, the control panel indicates this
event. If you want to uninstall the keypad, it must also be erased in the control
panel.
Technical specifications
Power supply 2x lithium batteries type CR123A (3.0V)
Typical battery lifetime approx. 3 years (with a max.of 2 daily activations)
Communication frequency 868 MHz, OASiS protocol
Communication range approx. 100m (open area)
RFID cards Jablotron PC-01 or PC-02 (EM UNIQUE 125kHz)
Door detector input IN = normally closed loop
Dimensions 120 x 130 x 30 mm
Environment according to EN 50131-1 II. internal
Operating temperature range -10 to +40 °C
EN 50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 classification 2
Complies with ETSI 300220, ETSI 300330, EN 50130-4,
EN 55022, EN 60950-1
Can be operated according to ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-80F is in compliance
with the essential requirements and other relevant provisions of Directive
1999/5/ECThe original of the conformity assessment can be found at
www.jablotron.com
, Technical Support section.
Note: Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer
after use.

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-81F bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-81F in de taal/talen: Engels als bijlage per email.

De handleiding is 0,09 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Jablotron JA-81F

Jablotron JA-81F Gebruiksaanwijzing - Deutsch - 1 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info