WORKING MODES OF THE H-906SA
Armed (AWAY) In this mode, all connected detectors can trigger an alarm. Detectors in the Delay Zone
will only trigger an alarm after the entrance delay.
Disarmed (HOME) In this mode, the system will not react to movement of people in the house. Detectors in
the 24Hr zone can still trigger an alarm.
Alarm If alarm is triggered, the control panel will switch on the siren and other installed
optional devices (telephone dialer, outdoor siren etc.). The alarm will reset
automatically after a predetermined period. The alarm can be stopped by the key
switch or by external controller if installed.
Service this mode can be selected only by using the key. You can service the system in this
mode (set & test sensors, set control panel etc.). No alarm can be triggered while in this
mode.
HOW TO OPERATE THE SYSTEM
The system is normally controlled by the key or by an external controller (digital keypad, remote control
etc.). If an external controller is installed, the control panel should be switched to the STAND BY position in
order to be able to accept the external controller instructions.
ARMING
To arm the system, switch the key to the ARM position (or use external controller if installed). The ARM
LED will start blinking (and the siren will sound once if the chirp function is enabled). A slow blinking of the
ARM LED indicates that the exit delay is activated. During the exit delay, any sensor in the Delay zone
can be activated without triggering the alarm. After the exit delay, the ARM LED lights permanently and all
zones are armed.
Note: No animal can stay in an area covered by motion detectors.
DISARMING
To disarm the system, switch the key to the STAND BY position (or use external controller if installed).
The ARM LED will switch off (and the siren will sound twice if the chirp function is enabled). If you trigger
any detector in the Delay zone before disarming, the system will provide an entrance delay. The entrance
delay is indicated by the fast blinking of the ARM LED and sounding of the optional chime buzzer, if
installed.
Note: If the disarming is confirmed by three chirps instead of two, check the control panel's LEDs for
important system information (alarm memory).
Zone location
Zone: protected area:
Delay L1
Instant L2
Instant L3
24 hr. L4
Exit/Entry delay: Alarm duration:
If troubles, call your installer phone:
JABLOTRON
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
tel.: 420-428--346911, fax: 420-428-313183
export@jablotron.cz
Alarm Control panel H-906SA
Description
The Hestia H-906SA is a wire operated home alarm system designed for easy installation and use. The
control panel provides four protection zones (24h, delay and two instant inputs). An assortment of
detectors can be connected to the control panel to suit your needs. Refer to the Jablotron catalog for more
details on optional detectors.
The control panel can be operated with the built-in key switch, or with an external controller (digital
keypad, remote control, hidden switch etc.). The H-906SA outputs can be connected to an external siren
(SA-105,SA-107), outdoor siren (OS-300), telephone dialer (TD-101, TD110) or a wireless pager (PG 2) to
alert of an alarm. Pre-alarm and Chirp signals are also available on H-906SA outputs.
SPECIFICATIONS
power required: 15VAC/10VA (DE-20-15 adapter can be used)
backup battery required: 12V, 1.3Ah (SA-214/1.3)
stand-by consumption: 30mA
back-up power output: 12V, max. 400mA
four zones: 24h, delay an two instant, all N.C. inputs
external ARM control input: pulse N.O. input
output rely: over-switching contact, 1A at 60 V
internal siren: 118 dB/1m
external siren output: 0.3A at 12 V
backup siren output: +BS
arm output: 0.2A to GND
chime output: 0.2A to GND
Complies with the essential requirements of: 89/336/EC EMC Directive - Protection concerning
electromagnetic compatibility when is used for its intended purpose.
Original of the conformity assessment
can be found at the web page
www.jablotron.cz, section Technical support.
Note: Dispose of batteries safely depending on the type of the batteries and local regulation. Although this
product does not contain any harmful materials we suggest you to return the product to the dealer or
directly to the producer after usage.
FRONT PANEL
POWER (Green LED) continuously lit indicates that the power supply is properly functioning. A blinking
led means that the system is powered only by the
back up battery. If this LED is off, the system has no
A.C. power and the back-up battery is discharged.
ARM (Yellow LED) if this LED is off, the system is
disarmed. If it is slowly blinking, it indicates an Exit
delay. A continuously lit LED indicates that the
system is fully armed. A rapidly blinking LED
indicates an Entrance delay.
ZONE STATUS LEDs: (DELAY, INSTANT, INSTANT, 24hr.).
When in the normal operating mode, a lit LED
indicates a triggered input. A slow blinking zone
LED indicates that there is some alarm memory
information. It can be reset by rearming. A rapidly
blinking zone means an alarm condition on the
control panel.
CONTROL KEY SWITCH has three positions: SERVICE -
you can service the system in this position (set control panel, test sensors, etc.).
POWER
ARM
DELAY
INSTANT
INSTANT
24 hr.
ZONE
ALARM SYSTEM
HESTIA
SERVICE ARM
STAND BY
H-906S
Alarm Control panel H-906SA 2 / 4 MCV51902 Alarm Control panel H-906SA 3 / 4 MCV51902
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron H-906SA bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron H-906SA in de taal/talen: Engels als bijlage per email.

De handleiding is 0,14 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info