Immobilizer CA-322 „Accent“ 2 / 1 MDF532 05
Immobilizer CA-322 „Accent“ - instructions
The „Accent“ brand name system is suitable for all cars equipped with 12V v oltage
and a negative ground. The CA-322 immobilizer is remotely controlled. RF
communication is protected by a FLOATING digital code and by an ANTI-SCAN
feature.
Arming and disarming of the system is confirmed by the turn indicators blinking.
While the ignition key is on, the system can not be armed. This protects the car from
having the system accidentally activated while driving. A v isual warning of the presence
of the immobilizer is provided by an LED indicator.
Door lock outputs allow the central locking system to be controlled by the remote
control (programmable output pulse duration). A signal to close electrically powered
windows is also av ailable.
An automatic Dome light control is provided by an ex tra door switch input/output
(negative trigger). It turns ON the dome light after disarming and the opening of any
door. The light will remain ON until you sw itch ON the ignition (max. 60 sec.).
A built in powerful immobilizer (3 relay contacts) can disable important systems
(starter, ignition, electrical fuel pump etc.).
The „Accent“ provides optional REARM and AUTOIM MO functions. REARM checks
if the car has been entered within one minute of disarming. If not, the immobilizer is
automatically rearmed and the doors are locked again. AUTOIMMO function will block
the car automatically if ignition key is turned off for more than 5 minutes. Optional
functions can be modified in setting mode by a professional mechanic after installation.
SPECIFICATIONS
voltage 10 - 16VDC
stand by consumption max. 20mA
working temperature -40 to +85°C
remote controller distance max. 20m
remote controller equipped with SAW resonator
coding digital floating code system with Anti-scan
turn indicator outputs 2 x +12V, max. 2 x 5A
central lock outputs pulses to GND, max. 300mA, 0.3 - 4sec.
optional „lock“ signal duration (for el. powered windows) 60sec.
immobilization relay contacts (3 loops) max. 15A permanently
max. 20A for 30 seconds
AUX output digital bus output (future use)
negative switched door contacts input / courtesy light output 10W
AL1 negative input / dome light output
VALET push button executive override, setting
All the data is stored to EEPROM memory.
This product complies with IEC 839-10-1, EEC No. 97
Hereby, Jablotron Ltd., declares that this CA-322 is in compliance with the essential
requirements and other relevant provisions of Directiv e 1999/5/EC. Original of the
conformity assessment can be found at the web page www.jabl otr on. cz
, section
Technical support.
Note: Although this product does not contain any harmful ma terials we suggest you
to return the product to the dealer or directly to the producer after usage.
INSTALLA TION
The immobiliz er will work only if properly installed. Improper installation of the
system can result in poor and or dangerous car performance. We recommend
having the immobiliz er professionally installed.
INSTALLA TION INSTRUCTIONS: Disconnect the battery before starting
installation. Keep in mind that if your car has some memory functions, these
may be erased if you disconnect the battery . Nobody should be inside the car
equipped with airbags when connecting or disconnecting the battery. R efer to
the car owners' manual before disconnecting the battery.
Install the control unit in the passenger compartment. The recommended
location is under the dash board. The wire coming directly from the control unit is
the remote control antenna. The location of this wire will effect the remote control
working distance. Ideally, the w ire should be near a window . If you drill a hole in
the car, be sure to check the area before drilling to prevent damage to the car.
LED indicator is on a separate cable. Once you have determined the
position on the dashboard where you w ant the LED light, drill a 6.5mm (4/16")
diameter hole in the dashboard and install the LED. Be sure to check for other
cables before you drill the hole. Connect the LED cable into any of the three
pin connectors on the main unit .
VALET Switch - has a separate cable. This push button switch can be used
as an executive override if the remote control is lost. How ever, if the VALE T
switch was optionally disabled in setting mode, it will not be able to ov erride.
Find a hidden place in the car and install the switch. Connect the cable to any
of the three pin connectors on the main unit.
WIRING - route wires for the immobilizer with the electrical harness of the car.
Check each connection made to ensure that it is solid and properly insulated.
Use only a real crimping tool to make connections. Complete and check all wiring
before switching on the power. Each w ire is marked by a number on its end
(remove the numbers after installation).
1 = Positive Supply - connect this wire to a direct line from the positive
terminal of the battery. This wire is split in the immobilizer wire harness. The
loop with the fuse (10Amp), is a separate power supply for turn lights. The
fuse protects against a short connection of the turn indicator bulb. Use only
a 10A fuse in this harness!
2 = Grounding - connect this wire to the original GND point in the car.
4 = „Lock“, 5 = „Unlock“ - these wires provide signals to control the central
door lock system. The max imum output current for either of these lines is
300mA. NPN transistors sw itching to the GND are on the output of these lines.
The duration of output pulses is programmable (0.3sec. factory default).
Connect the wires from the „Accent“ to the inputs of the central locking sy stem
control unit.
If the car has powered windows wi th a “close all windows” button y ou can
use the „Lock“ signal to close all the windows. In this case, select the longer
“Locking Signal“ in the setting mode This w ay the immobilizer will lock the
doors and will close all window s if button A (1) is used for arming and it w ill
only lock the doors if button B (2) is used.
Do NOT connect the wires from the immobiliz er directly to the actuators! See
"Examples of Accent use for different central locking systems" if your locking
system uses another type of control signals. If you are also going to install
a central locking system in your car, we recommend the CL-20A.
6 = Ignition Key Input - connect this w ire to the ignition key sw itch (+12V
when ignition is ON). This signal w ill prevent accidental arming of the sy stem
while driving. This signal is also used for R EARM and AUT OIMMO functions.
Note: Be sure, that +12V is also present, when a starter is used.
7 = Door Switches input, Dome Light Control output - is a negative trigger
input for REARM function. It also functions as the dome light control output.
Connect this wire to the door sw itches (we recommend to have sw itches installed
in all doors). With the system is disarmed, opening the door turns on the interior
dome light till the ignition key is switched on (max . 1 minute).
Note: The maximum load of the interior light can be 10W.
8 = AL 1 Negative Input for REARM function and dome light controlling. It
can be used for trunk switch.
13 and 14 = Turn Indicators - the two wires provide pow er for the left and
right turn indicators. Each wire prov ides 12V, 5A pulses to the lights as
a v i sual indication of arming and disarming. Connect one of the wires to the
left turn light and the other wire to the right turn light.
Immobilization - the six wires in a separate connector are the three built-in
immobilization contacts’ leads. The following wires are connected by internal
relay contacts inside: 1-3, 2-4, 5-6. The starter, fuel pump, ignition or any other
system that when electrically disconnected will render y our car inoperative, may
be connected here. Only disarming the system and switching O N the key in the
ignition closes the contacts. These contacts will operate correctly for permanent
load up to 15A, max. 20A for 30 seconds (each).
Adding of a new remote controller
There are two remote controllers in each „Accent“ immobilizer set. The sy stem
can be operated with a maximum of three remote controllers. T o add an
additional remote control or to replace an original one (in the case one is lost)
perform the following procedure:
Switch on the ignition key when immobilizer is disarmed and press the hidden
VALET button fiv e times (in 1 minute from the moment when you turned on the
ignition). The turn indicators will make two long signals and the LED will light
continuously. The control unit is now in remote control learning mode.
You must activate all remote controls (one by one, button A, B, 1 or 2) which y ou
want accepted by the immobilizer. The control unit will store codes in its memory
(confirmed by a LED flash and for a brand new code also by a turn lights signal).
Keep in mind that only three controllers can be taught to the immobilizer. If
you try to teach a fourth controller, the first one w ill be forgotten and so on. If
you activate only one controller in learning mode, you w ill be able to control
the system only w ith this one controller.
To close learning mode, switch off the ignition key. You can see how many
remote controls are available for your immobilizer by number of LED flashes every
time when you sw itch on the ignition key.
Setting mode
Optional functions can be modified. To enter the setting mode perform the
following procedure:
• press the hidden VALET button switch when the immobilizer is disarmed
and hold it pressed
• after 5 seconds (or more) switch on the ignition key
• the turn lights will make one long and one short signal and the LE D will light
continuously
• release the VALET button; the immobilizer is now in setting mode
Now you can make setting; see the follow ing table (you are in row no. 1).
Setting of the parameter is indicated by LED and can be changed by a remote
control button (A or B), each short pressing will change the parameter (on - off
- on - off - etc.). Bold printed parameters are factory default settings.
To select next parameter (nex t row in the table), press VA LET button quickly .
The turn lights will confirm parameter (row ) number by the number of signals.
Step by step go through all parameters. When you are on parameter number
5 the nex t VALET button pressing will store all the programming to the memory
and the setting mode will be exited (confirmed by the turn lights w ith one long
signal). If you switch the ignition key off any time before the setting mode is
completed, the setting mode will be terminated and no changes will be stored.
Note: All d ata is s tored to EEPROM me mory, so remo ving power from the
immobiliz er will not change them.
no. parameter R (on) status (LED) l (off) description
1 REARM enabled
disabled if car is not entered within 1 min. after disarming, it will arm again
2 AUTOIMMO enabled
disabled if enabled it will block engine if ignition key is switched off for more than 5 min.
3 duration of locking pulses 0,3 sec.
4 sec. modify „lock“ and „unlock“ output pulse duration
4 longer „lock“ si gnal
60 sec.
normal
the „lock“ pulse is normal (see step no. 3) or longer (60 seconds)
5
emergency disarm with VALET
enabled
disabled
if emergency disarm is disabled, VALET button can only be used for setting (emergency
disarm is possible only by a professional mechanic)