ACRO 52
Setting the Fail-Safe/Hold Memory in S-PCM Modulation
1. After accessing the Fail-Safe Function, it is time to adjust the
fail-safe presets.
2. Select all of the channels for which you want to enter a fail-
safe preset. This is done by pressing the left or right CH key
and moving the cursor arrow over the desired channel. Pressing
the + or - key will cause the particular channel to assume a
“hold” or “preset” fail-safe condition which is determined by
positioning the particular control and pressing the CLR key. The
transmitter will memorize the switch fail-safe position and
automatically transfer the setting to the receiver.
3. Confirmation of proper fail-safe presets/holds is made by
turning the transmitter OFF and observing the aircraft’s control
functions.
4.14 Fail-Safe/Hold (Function Mode), cont.
The XP8103 transmitter employs two separate types of trainer
systems:
A. Normal trainer system — all functions are controlled by
either the master transmitter or the slave transmitter.
B. Programmable function trainer — stick functions may be
assigned to the slave one at a time. Since the control functions
can be transferred one at a time, students can concentrate on
only one function at a time until they are competent to fly solo.
Basic Connections and Limitations
1. The slave transmitter must be PPM (Pulse Position Modulation)
with a DSC (direct servo control) jack. If the slave transmitter is
PPM/PCM selectable, select PPM. The master transmitter can be
S-PCM, Z-PCM or PPM.
2. Plug the trainer cord into each transmitter’s DSC jack. Note
each transmitter will appear to be ON, but neither is actually
transmitting at this time.
3. Switch the master transmitter ON. Do not switch on the
slave transmitter; you must only have the master transmitter
ON.
4. Pull the trainer switch on the master transmitter toward you to
transfer control to the slave. Releasing the switch automatically
reverts control to the master transmitter.
5. Be sure the slave transmitter servo reversing, dual rates, and
point adjustment and trims are identical to the master transmitter.
This can be checked by pulling the trainer switch toward you. If
the control surfaces move, adjust the slave transmitter until the
trainer switch can be activated without a change of the control
surface position.
A. Using the Normal Trainer System
In this mode, all functions are switched from the master to the
slave using the trainer switch. This is the normal mode. No
function set-up (reversing switch or travel adjust) is necessary to
activate this system.
4.15 Trainer (Function Mode)
When switch is in
upper position,
Fail-Safe is
activated
When switch is in
lower position, Hold
(last command) is
activated
Value represents the
stored position of
fail-safe mode of the
channel indicated by
the cursor