701292
9
Verklein
Vergroot
Pagina terug
1/13
Pagina verder
out of the preamp outputs of the amplifier are
compatible with the “Low” setting on the
“Input Range” control.
The “Signal Sensing” turn-on feature will not
work on “slave” amplifiers, but “slave” amplifiers
can be turned on and off by a “master” amplifier
operating in signal sensing turn-on mode.
Simply connect the “master” amplifier’s
“Remote” connection, to the “slave” amplifier(s)
“Remote” connection(s).
Do not increase the “Input Sens. setting for any
amplifier in the system beyond the maximum level
established during the procedure outlined in
Appendix B (page 14). Doing so will result in
audible distortion and possible speaker damage.
4) If you would like to run a third amplifier in
“Slave” configuration, select the “Full-Range”
position on the “Output Mode” switch of the first
“Slave” amplifier.Then, connect an RCA cable
from the first “Slave” amplifier’s preamp outputs to
the second “Slave” amplifier. As you did with the
first “Slave” amplifier, set the second “Slave”
amplifier’s “Amp LP Filter” to the “Off position.
Then, calibrate the third amplifier’s “Input Range”
and “Input Sens.controls in the same manner as
you did for the second amplifier.
Additional amplifiers may be added to this
“Master/Slave” configuration following the same
procedure as in step 4.
Once you match the input sensitivities of all the
amplifiers, you can use the “Master” amplifier’s
“Amp LP Filter” and “Advanced Bass Control”
features to control the “Slave” amplifier(s). If the
remote bass control (RBC-1) is used, it need only
be connected to the “Master” amplifier to control
all the amplifiers in the Master/Slave chain.
Below is a diagram showing a Master/Slave
configuration with one “Master” (top amplifier)
and two “Slave” amplifiers. Switches and controls
that are defeated in the “Slave” amplifiers are
printed in gray.
JL AUDIO 500/1 17
APPENDIX C:
Master/Slave Configurations
With the flexible on-board crossovers and
processing incorporated into the 500/1, it is
possible to connect multiple 500/1’s in a
“Master/Slave” configuration, with each amplifier
driving its own speaker system but controlled by
the processing and filtering of only one amplifier.
This is very useful when driving multiple
subwoofers with multiple amplifiers.
To create a Master/Slave configuration, first
determine which amplifier will be the “Master”
amplifier and connect the main input signal to that
amplifier (from the source unit or from an
outboard processor).This amplifier’s “Amp LP
Filter” section and “Advanced Bass Control”
features will process the signal for the “Slave”
amplifier or amplifiers.
Here is the procedure for implementing a
“Master/Slave” configuration:
1) Set the “Master” amplifier’s “Output Mode”
switch to the center “Amp Filter” position.This will
send a parallel, mono-summed signal from the
“Master” amplifier’s “Amp LP Filter” section to its
preamp outputs.
2) Connect an RCA cable from the “Master”
amplifier’s preamp outputs to the main input of the
first “Slave” amplifier. Set the “Slave” amplifier’s
“Amp LP Filter” to the “Offposition.This will
defeat the LP filter and the bass processing of this
“Slave Amplifier”.
3) The input sensitivity of the two amplifiers
needs to be adjusted independently.To properly
calibrate the amplifiers for maximum, identical, clean
output, please refer to Appendix B (page 14).
After using this procedure, you can then adjust the
level of the amplifiers by adjusting the input
sensitivities downward, if the amplifiers require
attenuation to achieve the desired system balance.
If the input sensitivities are adjusted, the amplifiers
must be recalibrated to ensure identical power
output levels.
Please note that the “Input Range” switch on
all “slave” amplifiers needs to be set to “Low”,
even if the “master” amplifier is high voltage and
its switch is set to “High”. All signals passed
16 JL AUDIO 500/1
MASTER:
JL AUDIO 500/1
monoblock subwoofer amplifier
+12VDC Ground Remote
JL AUDIO 500/1
monoblock subwoofer amplifier
+12VDC Ground Remote
JL AUDIO 500/1
monoblock subwoofer amplifier
+12VDC Ground Remote
The Master amplifier’s
Advanced Bass Control
section is active and affects
all three amplifiers equally.
The last Slave amplifier’s
Advanced Bass Control
section,AMP LP Filter and
Preamp Outputare inactive.
This Slave amplifier’s
Advanced Bass Control
section and AMP LP Filter are
inactive, but the Full-Range
(pass-through) feature of its
Preamp Outputfeeds the
input of the next Slave amplifier.
SLAVE (A):
SLAVE (B):
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw JL Audio 500 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van JL Audio 500 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,39 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info