12 | JL Audio - HD1200/1 Owners Manual
13
REMOTE LEVEL CONTROL OPTIONAL
With the addition of the optional Remote Level
Control (HD-RLC), you can control the volume of
the HD1200/1 from the front of the vehicle. This
is particularly useful for subwoofer level control.
The HD-RLC connects to the jack labeled
“Remote Level Control” on the Connection
Panel of the amplifier using a standard telephone
cable (supplied with the HD-RLC).
If desired, multiple HD amplifiers can be
controlled from a single HD-RLC controller
using a simple phone line “splitter” and multiple
phone cables (not supplied).
Remote
Level
Control
Inputs
L
R
L
R
+12 VDC Ground Remote
Preouts
+12 VDC Ground Remote
When connected to the amplifier, the HD-RLC
operates as follows. At full counter-clockwise
rotation, the audio will mute completely. At full
clockwise rotation the level will be the same as if
the HD-RLC was not connected at all. In other
words, it operates strictly as a level attenuator.
The RBC-1 Remote Bass Control used with
JL Audio Slash, Slash v2, e-Series, A-Series and
G-Series amplifiers is NOT compatible with the
HD Series amplifiers. If you attempt to connect
an RBC-1 to an HD amplifer, the control will
not work. You must use the HD-RLC controller.
SPEAKER CONNECTIONS
The HD1200/1 employs JL Audio’s exclusive
Regulated, Intelligent Power Supply (R.I.P.S.)
design. This sophisticated power supply allows
the amplifier to produce its optimum power (1200
watts x 1) over a wide range of supply voltage and
speaker impedances.
Remote
Level
Control
Inputs
L
R
L
R
+12 VDC Ground Remote
Preouts
+12 VDC Ground Remote
Unlike conventional amplifiers that require
a specific impedance to produce optimum
power, the R.I.P.S.-equipped HD1200/1 gives
you the freedom to use a variety of speaker
configurations that achieve final nominal
impedances between 1.5 – 4Ω (without
sacrificing power output or sound quality).
The operation of the R.I.P.S. circuitry is
entirely automatic and adjusts itself every time the
amplifier is turned on. There are no user controls
to configure. The system operates through
multiple stages of impedance optimization,
choosing the stage most appropriate to the actual
impedance of the speakers you connect to it.
If you connect a load higher than 4Ω nominal,
power will drop by half with every doubling of
impedance above 4Ω stereo. If you connect a
load lower than 1. nominal, the amplifier
protection circuitry activates a “safe” mode
which reduces amplifier power to protect the
circuitry from failure (the LED status indicator
on the control panel will light up amber to
indicate that this has happened). See page 14
for details.
OUTPUT POLARITY CONTROL
Depending on the distance relationship of
the mid-bass speakers and the subwoofers in a
system, it can be desirable to reverse the polarity
of the subwoofer system in order to produce
a better transition between subwoofer and
midbass speaker output. This is normally done
by swapping the positive and negative wires
connected to the subwoofer(s).
The “Output Polarity switch on the HD
1200/1 allows you to quickly peform this polarity
inversion without touching any wires. Simply
flip the switch from the “0” (normal) to the “180
deg.” (reversed) position.
Neither switch position is “correct” for every
system. Experiment to determine which polarity
produces the best overall bass performance
in your system, listening in particular to the
mid-bass smoothness and impact to make your
determination. If you change crossover slopes
or crossover filter frequencies, you may need to
revisit this control as these can affect the phase of
the speaker systems in the overlap region.
PREAMP OUTPUTS
The HD1200/1 incorporates a pass-through
preamp output section, so that additional
amplifiers can easily be connected to the same
signal(s) feeding the HD1200/1. These preamp
output signals are accessible via a stereo pair
of RCA-type jacks, labeled “Preouts”, on the
Connection Panel.
Remote
Level
Control
Inputs
L
R
L
R
+12 VDC Ground Remote
Preouts
+12 VDC Ground Remote
The term “pass-through” refers to the fact that
the Preamp Output signals are not affected by any
crossover filter or input sensitivity setting selected
on the HD1200/1 (if the input signal is full-range,
the Preamp Output will be full-range). These
preamp output signals are buffered to prevent
noise and are always preamp level, regardless of
the level of signals feeding the HD1200/1’s inputs.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw JL Audio 1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van JL Audio 1 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,09 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info