The atmospheric pressure can be displayed in mb/hPa or
inHg. To change the pressure unit, press and hold the
[UNIT] key at sea level pressure display and use [ ] or
[ ] (rear panel) key to select.
Press the [UNIT] key to confirm.
If you want to check the pressure history for a particular
hour during the past 36 hours, press the [HISTORY] button.
Each press on the button will go back by an hour.
The recorded atmospheric changes for the past 24 hour are
displayed in a bar chart above the atmospheric pressure window.
4. UV-MEASUREMENT
4a) Description
The UV-Index (UVI) is an international standard defining
the intensity of the UV radiation of the sun. The higher the
UVI, the stronger is the UV radiation of the sun and
therefore potentially harmful to humans.
The UVI makes you aware of this and helps you to choose
the correct protection.
5c) MAXIMUM AND MINIMUM
TEMPERATURES AND HUMIDITY
The maximum and minimum recorded indoor temperature,
humidity and outdoor temperatures will be automatically
stored in memory. To display them, Press [ MEM ] once
to display the maximum readings and again the minimum
readings. The respective indicators,
[ MAX ] or [ MIN ] will be displayed.
To clear the memory, hold down [ MEM ] for two seconds.
The maximum and minimum readings will be erased.
If you press [ MEM ] now, the maximum and minimum
readings will have the same values as the current ones until
different readings are recorded.
5d) TEMPERATURE ALARM
Weather Station is equipped with a temperature alarm
whereby a user-defined temperature can be selected.
When the selected temperature is reached an acoustic alarm
will be initiated. Temperature alarm is programmed as
follows:
1. Press the [TEMP ALARM] button.
2. Hold the [TEMP ALARM] button for 2 seconds.
3. Select the desired temperature for the alarm by using the
[ ] or [ ] buttons.
With one further pressing of the TEMP ALARM button
the data entered is confirmed.
The current and historical barometric pressure is shown
on the atmospheric pressure window. For user staying at
a higher altitude such as in the mountain area, see-level
barometric pressure applies. Use [PRESSURE /
ALTITUDE key to toggle the display to sea level pressure
display. Press and hold the Pressure/Altitude key to enter
the sea level pressure adjusting mode.
Use the [ ] or [ ] (rear panel) key to enter sea level
pressure and use [PRESSURE/ALTITUDE] to confirm.
5. THERMOMETER / HUMIDITY
5a) HOW TO CHECK REMOTE AND
INDOOR TEMPERATURES
The wave display on the outdoors temperature indicates the
reception of the remote unit is in good order. If no readings
are received from the remote unit for more than two minutes,
blanks “ ” will be displayed until further readings are
successfully searched. Check the remote unit is sound and
secure. You can wait for a little while or Hold [ ] for 2
seconds to enforce an immediate search. If the temperature or
humidity goes above or below than the measuring range of
the main unit or the remote unit (stated in specification), the
display will show “ ” & “HHH” or “LLL” respectively.
The unit can be set to automatically scan and display
readings from the remote sensors, the display will show
the readings from one channel for about 4-seconds and
then proceed to the next channel display.
-To activate the remote-sensor scanning mode:
Press and the hold the button [CHANNEL] for 2 seconds.
-To deactivate the remote-sensor scanning mode:
Press and the hold the button [CHANNEL] for 2 seconds.
5b) HOW TO READ THE KINETIC
WAVE DISPLAY
The kinetic wave display shows the signal receiving status
of the main unit. There are three possible forms:
The unit is in searching mode.
Temperature readings are
securely registered.
No signals.
˚C
3b) BAROMETRIC PRESSURE TREND
The atmospheric pressure indicator, in the weather forecast
window, uses arrows to indicate if the atmospheric
pressure is increasing, remaining stable, or decreasing.
TREND
TREND
TREND
Arrow
indicator
Pressure
Trend
Steady FallingRising
UV-Index Level Intensity Protection
0 -2.9
weak No protection necessary
3 - 5.9
medium
Protection necessary:
Hat, t-shirt, sun glasses, sun cream
6 - 7.9
high
Protection necessary:
Hat, t-shirt, sun glasses, sun cream
8 - 10.9
very high
Additional protection necessary:
Avoid to stay in unprotected areas
11+
extreme
Additional protection necessary:
Avoid to stay in unprotected areas
Symbol
4b) UV table and display indicates
3c) HOW TO CHECK THE
BAROMETRIC PRESSURE
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Irox HBVR761 UV-X bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Irox HBVR761 UV-X in de taal/talen: Engels als bijlage per email.

De handleiding is 1,49 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Irox HBVR761 UV-X

Irox HBVR761 UV-X Gebruiksaanwijzing - Deutsch - 7 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info