Initial startup and operation:
Before operating, be sure that:
All the hoses have been connected and tightened securely, and correct amount of filter sand
have been loaded.
The entire system is connected to a grounding type receptacle protected by a ground-fault
circuit interrupter (GFCI) or residual current device (RCD).
OPERATING INSTRUCTIONS (continued)
CAUTION
The filter control valve has a closed position. The pump should never
be on when the valve is in the closed position. If the pump is operated
with the valve closed, explosive situation could exist.
1.
Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valves to
allow water to flow into the sand filter pump. With water flowing into sand filter pump, the water
pressure will allow the air trapped inside to escape from the air release valves
(19)
. When all the
air has escaped water will flow out of the valves
(19)
. When this occurs gently finger tighten the
valves
(19)
in a clockwise direction.
IMPORTANT: To prevent air lock, open the lower plunger valve (connected inlet hose) first
and then the upper plunger valve (connected outlet hose). Open the air release valves, wait
until water starts to flow out of the air release valves, close air release valves.
2.
Ensure the drain/waste outlet on the 6-way valve is not covered and directed to a proper draining
receptacle.
3.
BACKWASH
- Ensure the pump is off, depress the 6-way valve
and turn it to the “
BACKWASH
” position
(see drawings 24 & 29)
.
IMPORTANT: To prevent damage to the 6-way valve, always
depress the valve handle before turning. Always switch off
pump before changing the 6-way valve position.
4.
Press
to switch on the system, and then press to set
the operating TIMER hours (see “Operating the system under
TIMER mode or manually” section for details). Water is circulating
backward through the sand media and to waste/drain outlet.
Backwash until a clear flow of water is observed in the waste/
drain outlet or through the drain sediment window.
NOTE:
If the LED display flashes “00”, the device is in stand-by mode and the pump will not
operate. The initial backwash of the filter is recommended to remove any impurities or fine sand
particles in the sand media.
5.
Switch off the pump, change the 6-way valve to “RINSE” position
(see drawing 25)
.
6.
Switch on the pump and run the pump for about one minute to level out the sand bed after
backwashing the sand media.
7.
Switch off the pump, change the 6-way valve to “FILTER” position
(see drawing 23)
.
8.
Switch on the pump. The system is now operating in the normal filtering mode. Run the pump
until the desired pool water clearance is obtained and no more than 12 hours per day. For the
initial startup, it is recommended setting the system to a longer TIMER operating hours or “FP” for
the pump to operate continuously without the TIMER.
9.
Record the initial pressure gauge reading when the filter media is clean.
NOTE:
During initial setup of the system, it may be necessary to backwash frequently due to
unusual heavy dirt present in the water and sand. After that, as the filter removes dirt and
impurities from the pool water, the accumulated dirt in the sand media will cause the pressure
to rise and the flow to diminish. If there is no vacuuming device attached to the system and
the pressure gauge reading is in the yellow zone it is time to backwash the sand media, see
“BACKWASH” under “initial startup and operation” section.
Vacuuming device (i.e. Intex auto pool cleaner) attached to the system may also cause the
flow to diminish and the pressure to rise. Remove any vacuuming device from the system and
check if the pressure gauge reading has dropped from the yellow zone to the green zone.
10.
Monitor the pressure gauge reading, and check that the inlet and outlet openings are not
obstructed on a weekly basis. If the pressure gauge indicates yellow it is time to backwash the
filter media.
29
1
2
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Intex SF60220-2 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Intex SF60220-2 in de taal/talen: Engels als bijlage per email.

De handleiding is 6,08 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Intex SF60220-2

Intex SF60220-2 Gebruiksaanwijzing - Deutsch - 23 pagina's

Intex SF60220-2 Gebruiksaanwijzing - Français - 24 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info