686103
5
Verklein
Vergroot
Pagina terug
1/19
Pagina verder
87PO
SAVE THESE INSTRUCTIONS
English
(87PO) ROUND METAL FRAME POOL ENGLISH 7.5” X 10.3” PANTONE 295U 05/25/2016
Page 5
Barriers for Residential Swimming Pool Guidelines:
An outdoor swimming pool, including an inground, aboveground, or onground pool, hot tub, or spa, should be
provided with a barrier which complies with the following:
1.
The top of the barrier should be at least 48 inches above grade measured on the side of the barrier which
faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of
the barrier should be 4 inches measured on the side of the barrier which faces away from the swimming
pool.Wherethetopofthepoolstructureisabovegrade,suchasanabovegroundpool,thebarriermay
beatgroundlevel,suchasthepoolstructure,ormountedontopofthepoolstructure.Wherethebarrieris
mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure
and the bottom of the barrier should be 4 inches.
2.
Openings in the barrier should not allow passage of a 4-inch diameter sphere.
3.
Solidbarriers,whichdonothaveopenings,suchasamasonryorstonewall,shouldnotcontain
indentations or protrusions except for normal construction tolerances and tooled masonry joints.
4.
Wherethebarrieriscomposedofhorizontalandverticalmembersandthedistancebetweenthetopsofthe
horizontalmembersislessthan45inches,thehorizontalmembersshouldbelocatedontheswimmingpool
sideofthefence.Spacingbetweenverticalmembersshouldnotexceed1-3/4inchesinwidth.Wherethere
are decorative cutouts, spacing within the cutouts should not exceed 1-3/4 inches in width.
5.
Wherethebarrieriscomposedofhorizontalandverticalmembersandthedistancebetweenthetopsof
thehorizontalmembersis45inchesormore,spacingbetweenverticalmembersshouldnotexceed4
inches.Wheretherearedecorativecutouts,spacingwithinthecutoutsshouldnotexceed1-3/4inchesin
width.
6.
Maximummeshsizeforchainlinkfencesshouldnotexceed
1-1/4
inch square unless the fence is provided
with slats fastened at the top or the bottom which reduce the openings to no more than 1-3/4 inches.
7.
Wherethebarrieriscomposedofdiagonalmembers,suchasalatticefence,themaximumopeningformed
by the diagonal members should be no more than 1-3/4 inches.
8.
AccessgatestothepoolshouldcomplywithSectionI,Paragraphs1through7,andshouldbeequipped
to accommodate a locking device. Pedestrian access gates should open outward, away from the pool, and
shouldbeself-closingandhaveaselflatchingdevice.Gatesotherthanpedestrianaccessgatesshould
haveaself-latchingdevice.Wherethereleasemechanismoftheself-latchingdeviceislocatedlessthan54
inchesfromthebottomofthegate,(a)thereleasemechanismshouldbelocatedonthepoolsideofthe
gateatleast3inchesbelowthetopofthegateand(b)thegateandbarriershouldhavenoopeninggreater
than 1/2 inch within 18 inches of the release mechanism.
9.
Whereawallofadwellingservesaspartofthebarrier,oneofthefollowingshouldapply:
(a) All doors with direct access to the pool through that wall should be equipped with an alarm which
produces an audible warning when the door and its screen, if present, are opened. The alarm should
sound continuously for a minimum of 30 seconds within 7 seconds after the door is opened. Alarms
shouldmeettherequirementsofUL2017General-PurposeSignalingDevicesandSystems,
Section77.Thealarmshouldhaveaminimumsoundpressureratingof85dBAat10feetandthe
sound of the alarm should be distinctive from other household sounds, such as smoke alarms,
telephones, and door bells. The alarm should automatically reset under all conditions. The alarm should
be equipped with manual means, such as touchpads or switches, to temporarily deactivate the alarm for
asingleopeningofthedoorfromeitherdirection.Suchdeactivationshouldlastfornomorethan15
seconds. The deactivation touchpads or switches should be located at least 54 inches above the
threshold of the door.
(b)
ThepoolshouldbeequippedwithapowersafetycoverwhichcomplieswithASTMF1346-91listed
below.
(c)
Other means of protection, such as self-closing doors with self-latching devices, are acceptable so long
asthedegreeofprotectionaffordedisnotlessthantheprotectionaffordedby(a)or(b)described
above.
10.
Whereanabovegroundpoolstructureisusedasabarrierorwherethebarrierismountedontopofthe
poolstructure,andthemeansofaccessisaladderorsteps,then(a)theladdertothepoolorsteps
shouldbecapableofbeingsecured,lockedorremovedtopreventaccess,or(b)theladderorsteps
shouldbesurroundedbyabarrier.Whentheladderorstepsaresecured,locked,orremoved,any
opening created should not allow the passage of a 4-inch diameter sphere.
Barriers should be located so as to prohibit permanent structures, equipment or similar objects from being
used to climb the barriers.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Intex Metal Frame - 28235 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Intex Metal Frame - 28235 in de taal/talen: Engels als bijlage per email.

De handleiding is 2,12 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info