685986
5
Verklein
Vergroot
Pagina terug
1/19
Pagina verder
86PO
S AVE THESE INSTRUCTIONS
(86PO) EASY SET POOL ENGLISH 7.5” X 10.3” PANTONE 295U 05/17/2016
English
Page 5
Barriers for Residential Swimming Pool Guidelines:
An outdoor swimming pool, including an inground, aboveground, or onground pool, hot tub, or spa, should be
provided with a barrier which complies with the following:
1.
The top of the barrier should be at least 48 inches above grade measured on the side of the barrier which
faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of
the barrier should be 4 inches measured on the side of the barrier which faces away from the swimming
pool. Where the top of the pool structure is above grade, such as an aboveground pool, the barrier may
be at ground level, such as the pool structure, or mounted on top of the pool structure. Where the barrier is
mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure
and the bottom of the barrier should be 4 inches.
2.
Openings in the barrier should not allow passage of a 4-inch diameter sphere.
3.
Solid barriers, which do not have openings, such as a masonry or stone wall, should not contain
indentations or protrusions except for normal construction tolerances and tooled masonry joints.
4.
Where the barrier is composed of horizontal and vertical members and the distance between the tops of the
horizontal members is less than 45 inches, the horizontal members should be located on the swimming pool
sideofthefence.Spacingbetweenverticalmembersshouldnotexceed1-3/4inchesinwidth.Wherethere
aredecorativecutouts,spacingwithinthecutoutsshouldnotexceed1-3/4inchesinwidth.
5.
Where the barrier is composed of horizontal and vertical members and the distance between the tops of
the horizontal members is 45 inches or more, spacing between vertical members should not exceed 4
inches.Wheretherearedecorativecutouts,spacingwithinthecutoutsshouldnotexceed1-3/4inchesin
width.
6.
Maximummeshsizeforchainlinkfencesshouldnotexceed
1-1/4
inch square unless the fence is provided
withslatsfastenedatthetoporthebottomwhichreducetheopeningstonomorethan1-3/4inches.
7.
Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening formed
bythediagonalmembersshouldbenomorethan1-3/4inches.
8.
Access gates to the pool should comply with Section I, Paragraphs 1 through 7, and should be equipped
to accommodate a locking device. Pedestrian access gates should open outward, away from the pool, and
shouldbeself-closingandhaveaselflatchingdevice.Gatesotherthanpedestrianaccessgatesshould
have a self-latching device. Where the release mechanism of the self-latching device is located less than 54
inchesfromthebottomofthegate,(a)thereleasemechanismshouldbelocatedonthepoolsideofthe
gateatleast3inchesbelowthetopofthegateand(b)thegateandbarriershouldhavenoopeninggreater
than 1/2 inch within 18 inches of the release mechanism.
9.
Where a wall of a dwelling serves as part of the barrier, one of the following should apply:
(a)
All doors with direct access to the pool through that wall should be equipped with an alarm which
produces an audible warning when the door and its screen, if present, are opened. The alarm should
soundcontinuouslyforaminimumof30secondswithin7secondsafterthedoorisopened.Alarms
shouldmeettherequirementsofUL2017General-PurposeSignalingDevicesandSystems,
Section 77. The alarm should have a minimum sound pressure rating of 85 dBA at 10 feet and the
sound of the alarm should be distinctive from other household sounds, such as smoke alarms,
telephones, and door bells. The alarm should automatically reset under all conditions. The alarm should
be equipped with manual means, such as touchpads or switches, to temporarily deactivate the alarm for
a single opening of the door from either direction. Such deactivation should last for no more than 15
seconds. The deactivation touchpads or switches should be located at least 54 inches above the
threshold of the door.
(b)
ThepoolshouldbeequippedwithapowersafetycoverwhichcomplieswithASTMF1346-91listed
below.
(c)
Other means of protection, such as self-closing doors with self-latching devices, are acceptable so long
asthedegreeofprotectionaffordedisnotlessthantheprotectionaffordedby(a)or(b)described
above.
10.
Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the
poolstructure,andthemeansofaccessisaladderorsteps,then(a)theladdertothepoolorsteps
shouldbecapableofbeingsecured,lockedorremovedtopreventaccess,or(b)theladderorsteps
should be surrounded by a barrier. When the ladder or steps are secured, locked, or removed, any
opening created should not allow the passage of a 4-inch diameter sphere.
Barriers should be located so as to prohibit permanent structures, equipment or similar objects from being
used to climb the barriers.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Intex Easy Set - 128146 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Intex Easy Set - 128146 in de taal/talen: Engels als bijlage per email.

De handleiding is 2,14 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Intex Easy Set - 128146

Intex Easy Set - 128146 Gebruiksaanwijzing - Nederlands - 12 pagina's

Intex Easy Set - 128146 Gebruiksaanwijzing - Deutsch - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info